优化脑放射外科MRI协议:序列与对比剂 timing 的作用
纳入49例患者414个脑转移瘤,随机分组比较MPRAGE、SPACE和VIBE序列及对比剂注射后不同时间点对肿瘤体积测量的影响。结果显示SPACE体积平均比MPRAGE大20%,VIBE比SPACE大10%;体积随时间增加,MPRAGE、SPACE和VIBE每分钟分别增加0.63%、0.58%和0.36%。
要点
- SPACE序列测量的脑转移瘤体积平均比MPRAGE大20%,VIBE比SPACE大10%。
- 对比剂注射后体积随时间增加,MPRAGE、SPACE、VIBE每分钟分别增加0.63%、0.58%、0.36%。
- 小于1 cm³病灶的序列间相对差异更大,主要因可见病灶边界变化。
核心结论
- MRI序列选择和对比剂注射后成像时间均显著影响SRT计划中脑转移瘤的表观体积,标准化协议对提高勾画准确性至关重要。
研究设计与样本
- 前瞻性随机分组研究,纳入49例患者414个脑转移瘤,随机分为6组,采用MPRAGE、SPACE和VIBE序列及对比剂注射后不同时间点成像;排除小于0.03 cm³的病灶;由放射科和放射肿瘤科专家独立评估体积。
临床应用与阅片要点
- 作者认为SPACE和VIBE序列可增强小病灶检出,但也可能增加边界模糊和观察者间变异;标准化协议需考虑序列和对比剂时机以改善勾画准确性、降低毒性风险并优化SRT结局。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Accurate target volume delineation is critical for effective stereotactic radiotherapy (SRT) of brain metastases. This study systematically investigates how MRI sequence selection and the time elapsed after contrast agent (CA) administration affect the apparent metastases volumes, with the goal of optimizing MRI protocols for radiation therapy planning.
MATERIALS AND METHODS: A total of 49 patients with 414 brain metastases were included and randomized into 6 groups with varying imaging sequences (MPRAGE, SPACE, and VIBE) and timepoints after CA administration. Lesions smaller than 0.03 cm3 were excluded due to resolution limitations. Lesion volumes were independently assessed by radiology and radiation oncology specialists, and mean values were analyzed. The effects of MRI sequence and time delay on lesion volume were evaluated using t tests, ANOVA, and multiple linear regression.
RESULTS: Both MRI sequence and CA timing significantly influenced measured volumes. On average, SPACE volumes were 20% larger than MPRAGE, and VIBE volumes were 10% larger than SPACE, independent of timing. Lesion volumes increased progressively with time after CA administration at rates of 0.63%, 0.58%, and 0.36% per minute for MPRAGE, SPACE, and VIBE, respectively. Smaller lesions (<1 cm3) showed greater relative intersequence differences, primarily due to variations in visible lesion borders.
CONCLUSIONS: Both MRI sequence choice and imaging time after CA administration significantly affect the apparent volume of brain metastases in SRT planning. Although SPACE and VIBE sequences enhance small lesion detection, they may also increase border blurring and inter-rater variability. Standardizing protocols to account for these factors is essential for improving delineation accuracy, reducing toxicity risk, and optimizing SRT outcomes.
引用
- Mangesius J, Kremser C, Birkl C, et al. Optimizing MRI Protocols for Brain Radiosurgery: The Role of Sequence and Contrast Agent Timing. Invest Radiol. 2025. PMID: 40980938. doi:10.1097/RLI.0000000000001238
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。