使用相位对比MRI量化人脑脊液沿主要动脉血管周围间隙的流动动力学
本研究前瞻性纳入28名健康参与者,在7-T相位对比MRI上开发半自动图像处理流程,定位并量化沿大脑中动脉血管周围间隙的脑脊液流动。线性混合效应模型显示导水管与三个血管周围区域的脑脊液流速呈正相关;远端皮质分支的流速曲线高度和标准差在两个年龄组间存在差异。
要点
- 半自动流程可在7-T相位对比MRI上定位并量化沿大脑中动脉血管周围间隙的脑脊液流速。
- 导水管与大脑中动脉三个血管周围区域的脑脊液流速呈正相关(P < .001)。
- 大脑中动脉远端皮质分支的脑脊液流速曲线高度和标准差在两个年龄组间有差异。
核心结论
- 开发了基于相位对比MRI的半自动算法流程,用于定位和量化沿大脑主要动脉血管周围间隙的年龄依赖性脑脊液动力学。
研究设计与样本
- 前瞻性单中心研究,连续纳入28名健康参与者,于2020年2月至2023年7月在Houston Methodist Research Institute接受对比剂未增强的7-T相位对比MRI。
关键影像表现/征象
- 血管检测采用链式滞回算法,设置两个可调参数:识别血管像素的高阈值和图像噪声截断的低阈值。
- 血管周围间隙通过膨胀算法检测。
- 在脑导水管和三个手动分割的血管周围区域测量脑脊液流速:区域1为颈内动脉和大脑中动脉M1分支,区域2为大脑中动脉M2段,区域3为大脑中动脉远端皮质分支或M3段。
诊断标准与关键数值
- 线性混合效应模型显示导水管与沿大脑中动脉三个区域的血管周围脑脊液流速呈正相关:0.013 cm/sec(P < .001)、0.024 cm/sec(P < .001)和0.010 cm/sec(P < .001)。
- 两个年龄组(20-39岁和40-59岁)间,大脑中动脉远端皮质分支的血管周围脑脊液流速曲线高度为0.06 vs 0.16 cm/sec(P = .002),标准差为0.02 vs 0.05 cm/sec(P < .001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Dysfunction in cerebrospinal fluid (CSF) flow dynamics is linked to several neurologic disorders. Although phase-contrast MRI has been used to measure them in the brain, studies in the perivascular space are lacking. Purpose To develop a pipeline of image processing algorithms using contrast-unenhanced 7-T phase-contrast MRI to locate and quantify human brain CSF dynamics along the perivascular space of major arteries and their branches. Materials and Methods In this prospective, single-center study, data were collected from healthy participants, enrolled consecutively, who underwent contrast-unenhanced 7-T phase-contrast MRI at the Houston Methodist Research Institute between February 2020 and July 2023. Data preprocessing included skull removal and contrast enhancement. Vessel detection was achieved by using a chained hysteresis algorithm with two tunable parameters: a high threshold for identifying vessel pixels and a low threshold for image noise cutoff. Perivascular space was detected using a dilation algorithm. CSF velocity was measured in the cerebral aqueduct and three manually segmented perivascular regions: region 1 (internal carotid artery and M1 branch of middle cerebral artery [MCA]), region 2 (M2 segment of MCA), and region 3 (distal cortical branches of MCA or M3 segment). Linear mixed-effects models were calculated between CSF velocity curves in the aqueduct and perivascular spaces to assess their relationship. Two-tailed Mann-Whitney U and F tests were used to assess differences in CSF velocity across two age groups (age 20-39 years and 40-59 years). Results A total of 28 participants (mean age, 40 years ± 11 [SD]; 14 male and 14 female participants) were included. A linear mixed-effects model showed a positive association between aqueduct and perivascular CSF velocity in three regions along the MCA (0.013 cm/sec [P < .001], 0.024 cm/sec [P < .001], and 0.010 cm/sec [P < .001]). Additionally, the height (0.06 vs 0.16 cm/sec; P = .002) and SD (0.02 vs 0.05 cm/sec; P < .001) of the perivascular CSF velocity curve in the distal cortical branches of the MCA differed between the two age groups. Conclusion A semiautomated pipeline of algorithms using phase-contrast MRI was developed to locate and quantify age-dependent human CSF dynamics along the perivascular spaces of major brain arteries. © RSNA, 2025 Supplemental material is available for this article.
引用
- Banta AR, D'Ambrosio R, Karmonik C, et al. Quantification of Perivascular Flow Dynamics of Human Cerebrospinal Fluid Along Major Arteries Using Phase-Contrast MRI. Radiology. 2025. PMID: 40985830. doi:10.1148/radiol.243521
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。