评估诊断一致性:超声视频用于肩袖撕裂分类的观察者内与观察者间一致性
回顾性横断面研究纳入138例疑似肩袖撕裂患者,以MRI为参考标准,比较3名专家与3名非专家对超声视频中冈上肌腱分类的观察者内与观察者间一致性及准确性。专家全撕裂检出准确率68.8%-84.8%,非专家63.0%-79.7%;专家观察者间一致性为中等(κ=0.42),非专家为一般(κ=0.38),观察者内一致性为一般(κ=0.35)。
要点
- 超声视频判读肩袖全撕裂,专家准确率68.8%-84.8%,非专家63.0%-79.7%,均以MRI为参考标准。
- 专家间全撕裂检出一致性中等(κ=0.42),非专家间一般(κ=0.38),观察者内一致性一般(κ=0.35)。
- 专家敏感性更高,从而获得更高的总体准确率。
核心结论
- 各经验水平的超声判读者与MRI相比均能准确识别超过80%的肩袖撕裂,专家判读者的准确性、敏感性和可靠性高于非专家;超声能可靠检出肩袖撕裂,并因其可及性和患者舒适度仍是首选的影像学方法,这凸显了标准化、培训和技术改进的必要性。
研究设计与样本
- 回顾性横断面研究,纳入138例疑似肩袖撕裂患者,采集冈上肌腱长轴动态扫查视频,以对应MRI结果为参考标准;3名非专家(研究生、医学生、放射科住院医师)和3名专家( fellowship培训的肌骨放射科医师、肌骨超声技师、放射科 fellow)依据预设标准独立将肌腱分类为正常、全层撕裂或部分层撕裂。
诊断标准与关键数值
- 全撕裂检出:专家准确率68.8%(95%CI 61.1-76.5)至84.8%(95%CI 78.8-90.9),非专家准确率63.0%(95%CI 54.9-71.1)至79.7%(95%CI 73.0-86.4);全层撕裂检出:专家准确率75.4%(95%CI 68.2-82.6)至87.0%(95%CI 81.4-92.6),非专家准确率73.9%(95%CI 66.6-81.2)至79.0%(95%CI 72.2-85.8);全撕裂检出观察者间一致性:专家中等(Light's κ=0.42,95%CI 0.30-0.58),非专家一般(κ=0.38,95%CI 0.32-0.50);观察者内一致性一般(κ=0.35,95%CI 0.29-0.43)。
临床应用与阅片要点
- 原文结论指出超声能可靠检出肩袖撕裂并仍是首选的影像学方法,同时强调需要标准化、培训和技术改进。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Ultrasound (US) is a more accessible alternative to MRI for rotator cuff tear (RCT) assessment. Rapid US can identify RCTs, but accurate US interpretation remains challenging, even for experts. We performed a retrospective cross-sectional study to evaluate intraobserver and interobserver agreement and accuracy in RCT detection with US between expert and non-expert readers.
MATERIALS AND METHODS: Long-axis cine sweeps of supraspinatus tendon from 138 patients with suspected RCTs were analyzed and compared to corresponding MRI results (reference standard). Three non-experts (graduate student, medical student, radiology resident) and three experts (fellowship-trained musculoskeletal (MSK) radiologist, MSK sonographer, and radiology fellow) independently classified tendons as normal, full-thickness tear, or partial-thickness tear by predefined criteria.
RESULTS: For all-tear detection (ATD), expert accuracy (%) ranged from 68.8 (95% CI, 61.1-76.5) to 84.8% (78.8-90.9), and non-expert accuracy from 63.0 (54.9-71.1) to 79.7% (73.0-86.4). For full-thickness tear detection (FTTD), expert accuracy ranged from 75.4 (68.2-82.6) to 87.0% (81.4-92.6), and non-expert accuracy from 73.9 (66.6-81.2) to 79.0% (72.2-85.8). Interobserver agreement for ATD was moderate among experts (Light's kappa ( κ ) = 0.42 (95% CI, 0.30-0.58)) and fair among non-experts ( κ = 0.38 (0.32-0.50)). Intraobserver agreement was fair ( κ = 0.35 (0.29-0.43)). Our experts achieved higher sensitivity, resulting in improved overall accuracy.
CONCLUSION: Ultrasound readers of all experience levels accurately identified over 80% of RCTs when compared with MRI. Expert readers achieved higher accuracy, sensitivity, and reliability than non-experts. Ultrasound reliably detects RCTs and remains the preferred imaging modality for its accessibility and patient comfort, underscoring the need for standardization, training, and technological improvements.
引用
- Ghosh S, Knight J, Wichuk S, et al. Evaluating diagnostic consistency: intra and interobserver agreement in rotator cuff tear classification using ultrasound videos. Skeletal Radiol. 2025. PMID: 40874990. doi:10.1007/s00256-025-05009-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。