文献速递骨肌MR

肌肉骨骼感染报告与数据系统(MSKI-RADS):多机构更广泛通用性研究

Musculoskeletal infection reporting and data system (MSKI-RADS): multi-institutional wider generalizability study.
PubMed 文献 · Eur Radiol · 2025-08-28

回顾性多中心研究评估MSKI-RADS在22名不同经验早期放射科医生中的阅片者间信度和诊断准确性,病例来自单中心210例肢体感染MRI;MSKI-RADS评分总体准确率66±10%,高于定性诊断的59±11%(p<0.05),阅片者间一致性中等(ICC 0.57)。

要点

  • MSKI-RADS评分总体准确率66±10%,高于定性诊断准确率59±11%(p<0.05)。
  • 22名阅片者间一致性中等(ICC 0.57,CI 0.52-0.67)。
  • 骨感染(IV和V类)平均真阳性率82%(95%CI 80-84%),高于软组织感染(II和III类)的66%(95%CI 63-68%)。

核心结论

  • MSKI-RADS是准确可靠的基于MRI的分类系统,用于早期职业放射科医生诊断一系列肌肉骨骼感染,表现与专家阅片者相似。

研究设计与样本

  • 回顾性多中心研究,22名来自9家机构的阅片者(放射科住院医师、MSK放射科临床研究员和初级MSK主治医师,1-8年经验),评估来自单中心的210例肢体感染病例MRI,经过专家阅片者初步培训后记录MSKI-RADS评分、最终定性诊断及两者置信度。

诊断标准与关键数值

  • MSKI-RADS分类:0-影像不完整,I-感染阴性,II-浅表软组织感染,III-较深软组织感染,IV-可能骨髓炎(OM),V-高度提示OM,VI-已知OM,NOS-与感染无关的非特异性骨病变。
  • 210例中:17例阴性,32例浅表软组织感染,39例较深软组织感染,24例可能OM,41例高度提示OM,18例已知OM,39例NOS。
  • 22名阅片者间一致性中等(ICC 0.57,CI 0.52-0.67)。
  • 非感染病例(I和NOS)平均真阳性率70%(95%CI 67-73%),软组织感染(II和III)66%(95%CI 63-68%),骨感染(IV和V)82%(95%CI 80-84%)。
  • V类和VI类平均真阳性率分别为80%(95%CI 77-82%)和86%(95%CI 82-89%)。

临床应用与阅片要点

  • MSKI-RADS评分在早期职业放射科医生中准确率高于定性诊断(66±10% vs 59±11%,p<0.05)。
  • MSKI-RADS评分与定性诊断的置信度无显著差异(3.56±0.91 vs 3.52±0.92,p>0.05)。

局限性

  • 数据集来自单中心。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To determine inter-reader reliability and diagnostic accuracy of MSKI-RADS among early-career radiologists with different experience levels.

MATERIALS AND METHODS: This is a retrospective multicenter study of MRIs of proven musculoskeletal (MSK) infections. MSKI-RADS categories included: 0-incomplete imaging, I-negative for infection, II-superficial soft tissue infection, III-deeper soft tissue infection, IV-possible osteomyelitis (OM), V-highly suggestive of OM, VI-known OM, and NOS-nonspecific bony lesions unrelated to infection. There were 22 readers from 9 institutions with 1-8 years of radiology experience, including radiology residents, MSK radiology clinical fellows, and junior MSK attendings. After initial training with expert readers, a dataset of 210 cases across a spectrum of extremity infections from a single institution was evaluated. The readers recorded the following for each case: MSKI-RADS score, final qualitative diagnosis, and confidence levels for both. Inter-reader agreements (ICC) and accuracy were obtained.

RESULTS: Among 210 cases, there were 17 negative, 32 superficial soft tissue infections, 39 deeper soft tissue infections, 24 possible OM, 41 highly suggestive of OM, 18 known OM, and 39 NOS cases. A moderate inter-reader agreement was seen for 22 readers (ICC: 0.57 (CI = 0.52, 0.67)). The average true positive rates for non-infectious cases (I and NOS), soft tissue infection (II and III), and bony infection (IV and V) were 70% (95% CI: 67-73%), 66% (95% CI: 63-68%), and 82% (95% CI: 80-84%), respectively. Average true positive rates for classes V and VI were 80% (95% CI: 77-82%) and 86% (95% CI: 82-89%), respectively. Overall, MSKI-RADS reader accuracy was 66 ± 10%, higher than the qualitative diagnosis accuracy of 59 ± 11% (p < 0.05). Average confidence levels for MSKI-RADS score and final qualitative diagnosis were 3.56 ± 0.91 and 3.52 ± 0.92, respectively (p > 0.05).

CONCLUSION: MSKI-RADS is an accurate and reliable MRI-based classification system for the diagnosis of a spectrum of musculoskeletal infections among early-career radiologists, like expert readers.

KEY POINTS: Question What is the inter-reader reliability and diagnostic accuracy of the musculoskeletal infection reporting and data system (MSKI-RADS) among early-career radiologists with different experience levels? Findings Overall reader accuracy using MSKI-RADS was significantly higher than the accuracy for final qualitative diagnoses, like the results of the initial validation study with expert readers. Clinical relevance MSKI-RADS is valid and reliable for diagnosis and grading of a spectrum of extremity musculoskeletal infections for early career radiologists of different experience levels, like expert readers.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Chhabra A, He A, Chalian M, et al. Musculoskeletal infection reporting and data system (MSKI-RADS): multi-institutional wider generalizability study. Eur Radiol. 2025. PMID: 40875018. doi:10.1007/s00330-025-11971-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。