针头规格选择对超声引导下甲状腺细针穿刺标本充分性的影响:系统综述与Meta分析
该系统综述与Meta分析纳入16项研究、3347例患者共3438个甲状腺结节,比较不同针头规格对超声引导下细针穿刺标本充分率的影响。结果显示较大与较小规格针头间充分率差异无统计学意义(-0.61%,95% CI:-4.18%至+2.97%,P=0.740)。作者认为针头规格选择不影响标本充分性,临床决策可基于患者舒适度、资源可及性和区域临床规范等因素。
要点
- 较大与较小规格针头甲状腺细针穿刺标本充分率差异无统计学意义。
- 年龄、性别、结节大小和研究类型对充分率无显著影响。
- 针头规格选择可依据患者舒适度、资源可及性和区域临床规范。
核心结论
- 系统综述与Meta分析提供有力证据表明针头规格选择对超声引导下甲状腺结节细针穿刺标本充分性无显著影响。
- 作者建议临床医生基于患者舒适度、资源可及性和区域临床规范等因素选择针头规格。
研究设计与样本
- 系统综述与Meta分析,检索PubMed、Web of Science、Embase和Cochrane Library数据库,检索日期为2024年12月22日。
- 纳入2010年后发表、比较甲状腺细针穿刺不同针头规格且有组织病理学确认的研究。
- 共纳入16项研究,涉及3347例患者、3438个甲状腺结节,采用QUADAS-2工具评估偏倚风险,使用STATA和MedCalc的随机效应模型分析数据。
诊断标准与关键数值
- 较大规格针头与较小规格针头标本充分率差异为-0.61%(95% CI:-4.18%至+2.97%,P=0.740),无统计学意义。
- 敏感性分析和发表偏倚评估显示结果稳健,无显著离群值或偏倚;Meta回归分析显示年龄、性别、结节大小和研究类型对充分率无显著影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare the impact of the various needle gauges employed in ultrasound-guided fine-needle aspiration (FNA) on the adequacy rate of specimens obtained from thyroid nodules.
METHODS: A systematic review and meta-analysis were performed employing PubMed, Web of Science, Embase, and Cochrane Library databases on December 22, 2024. Studies published post-2010 that compared various needle gauges in thyroid FNA with histopathological confirmation were included. The QUADAS-2 tool was utilized to assess the risk of bias. Data were analyzed using random-effects models in STATA and MedCalc. Heterogeneity was examined through subgroup analyses and meta-regression.
RESULTS: 16 studies involving 3347 patients with 3438 thyroid nodules were included. The meta-analysis indicated no statistically significant difference in adequacy rates between larger and smaller gauge needles (-0.61%, 95% CI: -4.18% to +2.97%, p-value=0.740). Sensitivity analysis and assessment of publication bias revealed strong findings, free from significant outliers or bias. Meta-regression analysis indicated that age, sex, nodule size, and study type did not significantly affect adequacy rates.
CONCLUSION: This systematic review with meta-analysis provides compelling evidence that the choice of needle gauge does not significantly influence the adequacy of US-guided FNA for thyroid nodules, suggesting clinicians make informed decisions about needle gauge selection based on factors beyond technical adequacy, such as patient comfort, resource availability, and adherence to regional clinical protocols.