表观扩散系数评估在O-RADS MRI鉴别含实性成分卵巢肿块中的附加价值
本回顾性队列研究纳入159例患者共218个卵巢肿块,按病理分为良性、交界性和恶性组,评估ADC值联合O-RADS MRI分类的诊断效能。O-RADS 3-4类与4-5类的最佳ADC截断值分别为1.36×10⁻³ mm²/sec和0.99×10⁻³ mm²/sec;采用ORADS-ADC分类后,3-4类敏感度从69.2%升至94.12%、特异度从88.4%升至98.36%、准确率从76.0%升至96.84%,4-5类敏感度从91.8%升至95.12%、特异度从62.3%升至97.06%、准确率从78.9%升至95.54%。结论认为将DWI和ADC测量纳入O-RADS MRI分类系统可显著改善卵巢肿瘤分类。
要点
- O-RADS MRI 3-4类与4-5类的最佳ADC截断值分别为1.36×10⁻³ mm²/sec和0.99×10⁻³ mm²/sec。
- 引入ORADS-ADC分类后,O-RADS 3-4类敏感度从69.2%升至94.12%、特异度从88.4%升至98.36%、准确率从76.0%升至96.84%。
- O-RADS 4-5类敏感度从91.8%升至95.12%、特异度从62.3%升至97.06%、准确率从78.9%升至95.54%。
核心结论
- 将DWI和ADC测量纳入O-RADS MRI分类系统可显著改善卵巢肿瘤分类,ORADS-ADC模型较传统O-RADS明显提高诊断准确率,同时提升敏感度和特异度,从而改善临床和治疗管理及手术规划中的患者结局。
研究设计与样本
- 回顾性队列研究,纳入159例患者共218个卵巢肿块,按组织病理学评估分为良性、交界性和恶性组;分析MRI参数包括实性成分大小和信号强度、时间-强度曲线(TIC)、ADC值及O-RADS分类;采用受试者工作特征(ROC)曲线分析确定鉴别肿瘤分类的最佳ADC截断值。
关键影像表现/征象
- 分析MRI参数包括实性成分大小和信号强度、时间-强度曲线(TIC)、ADC值及O-RADS分类。
诊断标准与关键数值
- O-RADS MRI 3-4类与4-5类之间的最佳ADC截断值分别为1.36×10⁻³ mm²/sec和0.99×10⁻³ mm²/sec。
- ORADS-ADC 3-4类:敏感度从69.2%升至94.12%,特异度从88.4%升至98.36%,准确率从76.0%升至96.84%。
- ORADS-ADC 4-5类:敏感度从91.8%升至95.12%,特异度从62.3%升至97.06%,准确率从78.9%升至95.54%。
临床应用与阅片要点
- 将DWI和ADC测量纳入O-RADS MRI分类系统可显著改善卵巢肿瘤分类,并改善临床和治疗管理及手术规划中的患者结局。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Integrating diffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC) measurements with existing MR imaging protocols improves the differentiation between benign and malignant adnexal lesions. We aimed to assess the additional value of quantitative ADC in diagnosing adnexal masses classified by the O-RADS-MRI score and evaluate the impact on diagnostic performance.
METHODS: This retrospective cohort study analyzed 159 patients with 218 ovarian masses, classified into benign, borderline, and malignant groups via histopathological evaluation. We examined MRI parameters, including solid component size and signal intensity, time-intensity curves (TICs), ADC values and O-RADS categories. Receiver Operating Characteristic (ROC) curve analysis determined optimal ADC cut-off values for differentiating tumor classifications.
RESULTS: The optimal cut-off values for the ADC between O-RADS MRI categories 3-4, and 4-5, were 1.36 × 10⁻³ mm²/sec and 0.99 × 10⁻³ mm²/sec respectively. the introduction of ORADS-ADC classification, utilizing these ADC cut-offs demonstrated superior diagnostic performance compared to traditional O-RADS, with improvements observed across several metrics: in ORADS-ADC 3-4 sensitivity increases from 69.2 to 94.12%, specificity from 88.4 to 98.36%, and accuracy from 76.0 to 96.84%. Similarly, in ORADS-ADC 4-5 sensitivity increases from 91.8 to 95.12%, specificity from 62.3 to 97.06%, and accuracy from 78.9 to 95.54%.
CONCLUSION: Incorporating DWI and ADC measurements into the O-RADS MRI classification system significantly improves ovarian tumor classification. The ORADS-ADC model markedly increases diagnostic accuracy, enhancing both sensitivity and specificity compared to traditional O-RADS, which consequently enhances clinical and therapeutic management resulting in better patient outcomes during surgical planning.
引用
- Moradi B, Kalantari S, Rahmani M, et al. The added value of apparent diffusion coefficient assessments in O-RADS MRI evaluation for characterizing ovarian masses with solid components. Abdom Radiol (NY). 2025. PMID: 40879694. doi:10.1007/s00261-025-05138-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。