文献速递妇产影像技术与安全US

超声弹性成像对子宫颈肿瘤的诊断与临床价值:一项综合系统评价与荟萃分析

Diagnostic and clinical utility of ultrasound elastography for uterine cervical neoplasms-a comprehensive systematic review and meta-analysis.
PubMed 文献 · Abdom Radiol (NY) · 2025-08-13

该研究系统检索截至2025年1月的23项研究(19项纳入荟萃分析),评估超声弹性成像对宫颈癌及宫颈上皮内瘤变的诊断准确性。弹性成像诊断宫颈癌的汇总敏感度88.3%、特异度92%、AUC 0.965;应变弹性成像较剪切波弹性成像诊断准确性有非显著升高趋势(p=0.51);定量参数可区分宫颈癌与对照及CIN。

要点

  • 弹性成像诊断宫颈癌汇总敏感度88.3%、特异度92%、AUC 0.965。
  • 应变弹性成像较剪切波弹性成像的诊断准确性有非显著升高趋势(p=0.51)。
  • 定量参数可区分宫颈癌与对照(SMD=2.59,p<0.001)及CIN(SMD=1.75,p=0.015)。

核心结论

  • 弹性成像以高敏感度和特异度辅助宫颈癌诊断,因经济、安全而适合资源有限环境;需标准化培训与指南以保证一致性使用;未来研究应比较SE与SWE、减少变异性、以MRI为基准并评估预后价值。

研究设计与样本

  • 系统评价与荟萃分析,遵循PRISMA 2020,注册号PROSPERO CRD42025639380;检索PubMed、Embase、Cochrane Library、Web of Science和Scopus至2025年1月;纳入23项研究,其中19项进入荟萃分析;采用Newcastle-Ottawa量表评估研究质量;用R软件和Stata计算汇总敏感度、特异度及SROC曲线,并评估异质性和发表偏倚。

关键影像表现/征象

  • 弹性成像用于检测宫颈癌的汇总敏感度为88.3%,特异度为92%,AUC为0.965。
  • 弹性成像对宫颈上皮内瘤变(CIN)也显示高诊断准确性。
  • 应变弹性成像较剪切波弹性成像的诊断准确性有非显著升高趋势(p=0.51)。
  • 定量参数可区分宫颈癌与对照(SMD=2.59,p<0.001)。
  • 定量参数可区分宫颈癌与CIN(SMD=1.75,p=0.015)。

诊断标准与关键数值

  • 弹性成像检测宫颈癌:汇总敏感度88.3%、特异度92%、AUC 0.965。
  • 应变弹性成像与剪切波弹性成像诊断准确性比较:p=0.51,差异未达统计学显著。
  • 定量参数区分宫颈癌与对照:SMD=2.59,p<0.001。
  • 定量参数区分宫颈癌与CIN:SMD=1.75,p=0.015。

临床应用与阅片要点

  • 弹性成像可辅助鉴别宫颈良恶性病变,并可用于评估治疗反应和肿瘤浸润。
  • 作者认为弹性成像因经济、安全而适合资源有限环境用于宫颈癌诊断。
  • 作者指出需标准化培训与指南以保证弹性成像的一致性使用。
  • 作者建议未来研究应比较SE与SWE、减少变异性、以MRI为基准并评估预后价值。

局限性

  • 原文结论指出需标准化培训与指南以保证一致性使用。
  • 原文结论指出未来研究应比较SE与SWE、减少变异性、以MRI为基准并评估预后价值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Cervical cancer remains a major burden, especially in low-resource settings, due to limited screening. Traditional diagnostic tools, like colposcopy, are operator-dependent and often lack accuracy. Ultrasound elastography, including strain elastography (SE) and shear wave elastography (SWE), is a cost-effective, non-invasive tool for assessing tissue stiffness, aiding in distinguishing benign from malignant cervical lesions, and monitoring treatment. This review evaluates elastography's diagnostic accuracy and clinical utility in cervical cancer management.

METHODS: This systematic review and meta-analysis was performed following PRISMA 2020 guidelines and was registered with PROSPERO (CRD42025639380). PubMed, Embase, Cochrane Library, Web of Science, and Scopus were searched up to January 2025 for studies utilizing elastography in cervical cancer. Study quality was assessed using the Newcastle-Ottawa Scale. Pooled sensitivity, specificity, and SROC curves were calculated using R software and Stata, with heterogeneity and publication bias evaluated.

RESULTS: A total of twenty-three studies were included, with 19 in the meta-analysis. Elastography demonstrated high diagnostic accuracy for both detecting cervical cancer (sensitivity 88.3%, specificity 92%, AUC 0.965) and cervical intraepithelial neoplasia (CIN). SE trended to a non-significantly higher diagnostic accuracy than SWE (p = 0.51). Quantitative parameters differentiated cervical cancer from controls (SMD = 2.59, p < 0.001) and CIN (SMD = 1.75, p = 0.015). Elastography can effectively assess treatment response and tumor invasion.

CONCLUSION: Elastography aids cervical cancer diagnosis with high sensitivity and specificity, ideal for resource-limited settings due to its affordability and safety. Standardized training and guidelines are needed for consistent use. Future studies should compare SE and SWE, minimize variability, benchmark against MRI, and assess prognostic value.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Mahdavi Sabet F, Forghani S, Shahsavand A, et al. Diagnostic and clinical utility of ultrasound elastography for uterine cervical neoplasms-a comprehensive systematic review and meta-analysis. Abdom Radiol (NY). 2025. PMID: 40802052. doi:10.1007/s00261-025-05159-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。