晚发型胎儿生长受限的膈肌功能:基于超声量化的研究
这项前瞻性队列研究纳入40例晚发型胎儿生长受限(LO-FGR)胎儿与40例胎龄匹配的健康对照,用超声测量膈肌厚度、厚度分数、移动度及肋膈角。LO-FGR组各项膈肌参数均显著降低,且合并不良围产结局者膈肌厚度、厚度分数和移动度更低;吸气末膈肌厚度对复合不良围产结局的预测AUC为0.923,优于多普勒指标。
要点
- 晚发型FGR胎儿膈肌厚度、厚度分数、移动度及呼气末肋膈角均较健康对照显著降低(P < .001)。
- 合并复合不良围产结局的FGR胎儿吸气末和呼气末膈肌厚度、厚度分数、移动度进一步显著降低(P < .001)。
- 吸气末膈肌厚度预测复合不良围产结局的AUC为0.923,优于呼气末膈肌厚度(0.865)和膈肌移动度(0.786)。
核心结论
- 膈肌超声衍生功能参数可作为预测晚发型胎儿生长受限不良围产结局的临床相关生物标志物;将膈肌超声纳入标准产前评估流程可能有助于改善该病的监测与管理。
研究设计与样本
- 前瞻性队列研究,纳入40例晚发型胎儿生长受限胎儿和40例胎龄匹配的健康对照,采用超声测量膈肌功能参数。
关键影像表现/征象
- 晚发型胎儿生长受限组吸气末和呼气末膈肌厚度、膈肌厚度分数、膈肌移动度及呼气末肋膈角均较健康对照组显著降低(P < .001)。
- 晚发型胎儿生长受限合并复合不良围产结局者,吸气末和呼气末膈肌厚度、膈肌厚度分数及膈肌移动度均较未合并者显著降低(P < .001)。
诊断标准与关键数值
- 吸气末膈肌厚度预测复合不良围产结局的AUC为0.923,呼气末膈肌厚度AUC为0.865,膈肌移动度AUC为0.786。
- 复合不良围产结局定义为5分钟Apgar评分低于7分和/或婴儿呼吸系统并发症或新生儿重症监护室(NICU)收治。
- 膈肌超声参数对复合不良围产结局的预测能力优于多普勒测量指标。
临床应用与阅片要点
- 在晚发型胎儿生长受限的产前超声评估中,可测量吸气末和呼气末膈肌厚度、膈肌厚度分数、膈肌移动度及肋膈角,其中吸气末膈肌厚度对复合不良围产结局的预测价值最高(AUC 0.923)。
- 膈肌超声参数对复合不良围产结局的预测能力优于多普勒测量,提示可将膈肌功能评估补充到常规产前监测中。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: We aimed to investigate diaphragm functions via ultrasonography in fetuses with late-onset fetal growth restriction (LO-FGR) and to examine the relationship of these parameters with composite adverse perinatal outcomes (CAPO).
METHODS: This prospective cohort study included 40 fetuses with LO-FGR and 40 healthy controls matched for gestational age. Diaphragmatic functions were evaluated using ultrasonography by measuring diaphragm thickness (DT) during inspiration and expiration, diaphragm thickness fraction (DTF), diaphragm excursion (DE), and costophrenic angle (CPA). CAPO was defined as a 5-minute Apgar score of less than 7 and/or infant respiratory complications or admission to the neonatal intensive care unit (NICU). The LO-FGR group was categorized into 2 subgroups: those with CAPO and those without. Statistical analyses evaluated the association between sonographic measurements of the diaphragm and CAPO.
RESULTS: In the LO-FGR group, DT (both inspiratory and expiratory), DTF, DE, and expiratory CPA were markedly reduced (P < .001). In LO-FGR cases that developed CAPO, DT (both inspiratory and expiratory), DTF, and DE were significantly lower (P < .001). Inspiratory DT exhibited the best predictive value for CAPO (area under the curve [AUC]: 0.923), followed by expiratory DT (AUC: 0.865) and DE (AUC: 0.786). Additionally, DUS parameters exhibited better predictive capability relative to Doppler measurements.
CONCLUSION: Diaphragmatic ultrasonography-derived functional parameters serve as clinically relevant biomarkers for predicting unfavorable perinatal outcomes in LO-FGR. The incorporation of DUS into standard prenatal assessment procedures may enhance the monitoring and management of LO-FGR cases.
引用
- Ağaoğlu RT, Bayrak AÇ, Akbulut ÖV, et al. Diaphragmatic Function in Late-Onset FGR Insights From Ultrasound-Based Quantification: Insights from Ultrasound-Based Quantification. J Ultrasound Med. 2025. PMID: 40751675. doi:10.1002/jum.70025
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。