肾CT血管成像团注跟踪技术的最佳触发阈值研究
本回顾性研究纳入2019年7月至2021年8月接受肾CTA的可疑肾病患者和候选肾移植供者,比较50 HU与100 HU两种触发阈值。结果显示两组主动脉和肾动脉CT值相当,但50 HU组适当肾动脉期图像比例更高,100 HU组肾皮质和肾静脉CT值更高。
要点
- 50 HU触发阈值较100 HU更易获得适当的肾动脉期图像。
- 两组主动脉和肾动脉CT值无显著差异(P=0.38-0.95)。
- 100 HU组肾皮质和肾静脉CT值高于50 HU组(P=0.006-0.04)。
核心结论
- 在采用团注跟踪技术的肾CTA方案中,50 HU触发阈值较100 HU触发阈值获得适当肾动脉期图像的概率更高。
研究设计与样本
- 回顾性研究,纳入2019年7月至2021年8月接受肾CTA的可疑肾病患者和候选肾移植供者共105例(平均年龄59.8岁,男性60例),分为50 HU组(n=42)和100 HU组(n=63)。
诊断标准与关键数值
- 50 HU组适当肾动脉期、晚期肾动脉期和皮髓质期比例分别为78.6%、19.0%和2.4%(阅片者1,P=0.01 vs 100 HU组)。
- 100 HU组适当肾动脉期、晚期肾动脉期和皮髓质期比例分别为50.8%、34.9%和14.3%(阅片者1,P=0.01 vs 50 HU组)。
- 50 HU组适当肾动脉期、晚期肾动脉期和皮髓质期比例分别为64.3%、33.3%和2.4%(阅片者2,P<0.001 vs 100 HU组)。
- 100 HU组适当肾动脉期、晚期肾动脉期和皮髓质期比例分别为27.0%、63.5%和9.5%(阅片者2,P<0.001 vs 50 HU组)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study aimed to investigate the optimal trigger threshold for the renal CT angiography (CTA) protocol with the bolus-tracking technique.
METHODS: This retrospective study included patients suspected of having renal diseases and candidate kidney transplant donors who underwent renal CTA from July 2019 to August 2021. Renal arterial (RA) phase scanning was initiated using either one of the following two trigger thresholds: 50 HU (50-HU group; n = 42) and 100 HU (100-HU group; n = 63). A radiologist measured CT attenuations of the vasculature and renal parenchyma on RA phase images. Two radiologists classified RA phase images into appropriate RA-, late RA-, or corticomedullary (CM)-timing. Unpaired t- and Fisher's exact tests were conducted to assess differences in the CT attenuations and the proportion of categorical classifications between the two groups.
RESULTS: Overall, 105 patients (mean age: 59.8 years; 60 men) were included. CT attenuations of the aorta and renal arteries were comparable between the two groups (P = 0.38-0.95). CT attenuations of the renal cortex and renal vein were higher in the 100-HU group than in the 50-HU group (P = 0.006-0.04). The proportion of the appropriate RA-timing was higher, whereas that of the CM-timing was lower in the 50-HU group than in the 100-HU group (appropriate RA-, late RA-, and CM-timing: 78.6% vs. 50.8%, 19.0% vs. 34.9%, and 2.4% vs. 14.3%; P = 0.01 for reviewer 1 and 64.3% vs. 27.0%, 33.3% vs. 63.5%, and 2.4% vs. 9.5%; P < 0.001 for reviewer 2, respectively).
CONCLUSION: The trigger threshold of 50 HU provided a higher probability of obtaining appropriate RA-timing images than that of 100 HU in the renal CTA protocol with the bolus-tracking technique.
引用
- Asano M, Noda Y, Kawai N, et al. Optimal trigger threshold with the bolus-tracking technique for the renal CT angiography protocol. Abdom Radiol (NY). 2025. PMID: 40853470. doi:10.1007/s00261-025-05158-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。