FOCUS-DWI结合IQMR深度学习重建技术提高前列腺癌检出率
回顾性分析62例前列腺肿块患者(良性31例、恶性31例)的MRI图像,比较FOCUS-DWI与经IQMR后处理的IQMR-FOCUS-DWI序列。IQMR-FOCUS-DWI在噪声抑制、几何变形及整体图像质量上显著优于FOCUS-DWI(P < 0.001),诊断置信度更高(P = 0.0002),鉴别良恶性病灶的AUC为0.941 vs 0.832(P = 0.0487)。
要点
- IQMR-FOCUS-DWI较FOCUS-DWI显著改善噪声抑制、减少几何变形并提升整体图像质量(P < 0.001)。
- IQMR-FOCUS-DWI诊断置信度显著高于FOCUS-DWI(P = 0.0002),但两组PI-RADS评分无显著差异(P = 0.0875)。
- IQMR-FOCUS-DWI鉴别前列腺良恶性病灶AUC = 0.941,优于FOCUS-DWI的AUC = 0.832(P = 0.0487)。
核心结论
- IQMR-FOCUS-DWI较常规FOCUS-DWI显著提升图像质量并提高前列腺良恶性病灶的诊断准确性。
研究设计与样本
- 回顾性分析62例前列腺肿块患者(良性31例、恶性31例)的临床资料和MRI图像,采集轴位T2WI-FS和FOCUS-DWI序列,FOCUS-DWI经IQMR后处理系统生成IQMR-FOCUS-DWI图像,以T2WI-FS为参考标准进行定量分析。
关键影像表现/征象
- IQMR-FOCUS-DWI图像噪声抑制显著更好、几何变形减少、整体质量显著优于FOCUS-DWI(P < 0.001)。
- 两组序列PI-RADS评分无显著差异(P = 0.0875),IQMR-FOCUS-DWI诊断置信度显著高于FOCUS-DWI(P = 0.0002)。
- 两种序列中良性病灶ADC值均显著高于恶性病灶(P < 0.001)。
诊断标准与关键数值
- IQMR-FOCUS-DWI鉴别前列腺良恶性病灶AUC = 0.941,FOCUS-DWI AUC = 0.832(P = 0.0487)。
- FOCUS-DWI序列诊断结果与病理结果一致(P < 0.05),IQMR-FOCUS-DWI序列诊断结果亦与病理结果一致(P < 0.05)。
- IQMR-FOCUS-DWI图像PSNR、SSIM及ADC值均显著高于FOCUS-DWI图像(P < 0.01)。
- 恶性病灶中,FOCUS-DWI序列ADC值与Gleason分级呈中度负相关,IQMR-FOCUS-DWI序列ADC值与Gleason分级呈强负相关。
临床应用与阅片要点
- IQMR后处理可改善FOCUS-DWI的图像质量与诊断置信度,有助于前列腺良恶性病灶的鉴别。
- 两种序列诊断置信度评分均与诊断准确率呈显著正相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: This study explored the effects of using Intelligent Quick Magnetic Resonance (IQMR) image post-processing on image quality in Field of View Optimized and Constrained Single-Shot Diffusion-Weighted Imaging (FOCUS-DWI) sequences for prostate cancer detection, and assessed its efficacy in distinguishing malignant from benign lesions.
METHODS: The clinical data and MRI images from 62 patients with prostate masses (31 benign and 31 malignant) were retrospectively analyzed. Axial T2-weighted imaging with fat saturation (T2WI-FS) and FOCUS-DWI sequences were acquired, and the FOCUS-DWI images were processed using the IQMR post-processing system to generate IQMR-FOCUS-DWI images. Two independent radiologists undertook subjective scoring, grading using the Prostate Imaging Reporting and Data System (PI-RADS), diagnosis of benign and malignant lesions, and diagnostic confidence scoring for images from the FOCUS-DWI and IQMR-FOCUS-DWI sequences. Additionally, quantitative analyses, specifically, the peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM), were conducted using T2WI-FS as the reference standard. The apparent diffusion coefficients (ADCs) of malignant and benign lesions were compared between the two imaging sequences. Spearman correlation coefficients were calculated to evaluate the associations between diagnostic confidence scores and diagnostic accuracy rates of the two sequence groups, as well as between the ADC values of malignant lesions and Gleason grading in the two sequence groups. Receiver operating characteristic (ROC) curves were utilized to assess the efficacy of ADC in distinguishing lesions.
RESULTS: The qualitative analysis revealed that IQMR-FOCUS-DWI images showed significantly better noise suppression, reduced geometric distortion, and enhanced overall quality relative to the FOCUS-DWI images (P < 0.001). There was no significant difference in the PI-RADS scores between IQMR-FOCUS-DWI and FOCUS-DWI images (P = 0.0875), while the diagnostic confidence scores of IQMR-FOCUS-DWI sequences were markedly higher than those of FOCUS-DWI sequences (P = 0.0002). The diagnostic results of the FOCUS-DWI sequences for benign and malignant prostate lesions were consistent with those of the pathological results (P < 0.05), as were those of the IQMR-FOCUS-DWI sequences (P < 0.05). The quantitative analysis indicated that the PSNR, SSIM, and ADC values were markedly greater in IQMR-FOCUS-DWI images relative to FOCUS-DWI images (P < 0.01). In both imaging sequences, benign lesions exhibited ADC values markedly greater than those of malignant lesions (P < 0.001). The diagnostic confidence scores of both groups of sequences were significantly positively correlated with the diagnostic accuracy rate. In malignant lesions, the ADC values of the FOCUS-DWI sequences showed moderate negative correlations with the Gleason grading, while the ADC values of the IQMR-FOCUS-DWI sequences were strongly negatively associated with the Gleason grading. ROC curves indicated the superior diagnostic performance of IQMR-FOCUS-DWI (AUC = 0.941) compared to FOCUS-DWI (AUC = 0.832) for differentiating prostate lesions (P = 0.0487).
CONCLUSION: IQMR-FOCUS-DWI significantly enhances image quality and improves diagnostic accuracy for benign and malignant prostate lesions compared to conventional FOCUS-DWI.
引用
- Zhao Y, Xie XL, Zhu X, et al. FOCUS-DWI improves prostate cancer detection through deep learning reconstruction with IQMR technology. Abdom Radiol (NY). 2025. PMID: 40748461. doi:10.1007/s00261-025-05100-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。