文献速递腹部CT

半自动与自动分割在活体肝移植术前移植物体积评估中的比较

Semi-automatic and automatic segmentation in the preoperative assessment of graft volume before living donor liver transplantation.
PubMed 文献 · Eur J Radiol · 2025-08-18

本回顾性研究纳入2022至2024年95例活体肝移植供者,比较一种半自动(Vitrea, Canon)与两种自动(Synapse, Fujifilm 和 United Imaging, UI)CT体积测量工作站估算右叶、左叶及左外侧段移植物体积与术中实际重量的准确性。三种方法与实际重量均强相关(p < 0.001),Synapse的肝脏分析软件在右叶体积估算中准确性显著更高(p < 0.001),在左外侧段估算中优于Vitrea(p < 0.001)和UI(p = 0.006);观察者间一致性高,供者年龄和性别无显著影响。

要点

  • Synapse肝脏分析软件估算右叶和左外侧段体积准确性最高。
  • 三种CT体积测量工作站与术中实际移植物重量均强相关(p < 0.001)。
  • 观察者间一致性高,供者年龄和性别对估算准确性无显著影响。

核心结论

  • 三种体积测量工具均可靠且易于使用,可用于活体肝移植术前规划;其中Synapse的肝脏分析软件在评估右叶和左外侧段体积时准确性最高,可能为手术决策提供潜在优势。

研究设计与样本

  • 回顾性研究纳入2022至2024年95例活体肝移植供者(右叶67例、左叶12例、左外侧段16例),比较一种半自动(Vitrea, Canon)与两种自动(Synapse, Fujifilm 和 United Imaging, UI)CT体积测量工作站,以术中实际移植物重量为参考标准。

诊断标准与关键数值

  • 三种方法与术中实际移植物重量均强相关(p < 0.001)。
  • Synapse的肝脏分析软件在右叶体积估算中准确性显著高于其他方法(p < 0.001)。
  • Synapse在左外侧段估算中准确性显著高于Vitrea(p < 0.001)和UI(p = 0.006)。
  • 观察者间一致性高,供者年龄或性别对估算准确性无显著影响。

临床应用与阅片要点

  • 三种CT体积测量工作站均可用于活体肝移植术前供肝体积评估。
  • Synapse的肝脏分析软件在右叶和左外侧段体积估算中准确性最高,可能为手术决策提供潜在优势。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Accurate preoperative liver volumetry is essential for successful living donor liver transplantation (LDLT). Manual CT volumetry is time-consuming and operator-dependent, prompting the development of semi -automated and automated methods. The aim of this study is to compare the accuracy of one semi-automated (Vitrea, Canon) and two automated (Synapse, Fujifilm and United Imaging, UI) CT volumetry workstations in estimating liver graft volume of the right lobe, left lobe, and left lateral segment relative to intraoperative graft weight.

METHODS: This retrospective study included 95 living liver donors (67 right lobe, 12 left lobe, and 16 left lateral segments) who underwent LDLT from 2022 to 2024. Estimated graft volumes were compared with actual graft weight (AGW). Correlation, percentage error, interobserver agreement, and potential influences of donors' age and gender on estimation accuracy were assessed.

RESULTS: All three methods demonstrated strong correlation with AGW (p < 0.001). Application Liver Analysis of the workstation Synapse showed significantly higher accuracy in the right lobe volume estimation compared to the others (p < 0.001), as well as in the left lateral segment estimation compared to Vitrea (p < 0.001) and UI (p = 0.006). Interobserver agreement was high, and no significant influence of donors' age or gender was found.

CONCLUSION: All three volumetry tools are reliable and user-friendly for preoperative planning for LDLT. Among them, Liver Analysis of Synapse demonstrated the highest accuracy in assessing right lobe and left lateral sector volumes, offering potential advantages in surgical decision-making.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Baiguissova D, Kalshabay Y, Martino MD, et al. Semi-automatic and automatic segmentation in the preoperative assessment of graft volume before living donor liver transplantation. Eur J Radiol. 2025. PMID: 40839914. doi:10.1016/j.ejrad.2025.112367

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。