文献速递腹部技术与安全介入US

床旁超声成像自动检测腹部出血:一项系统综述

Point-of-Care Ultrasound Imaging for Automated Detection of Abdominal Haemorrhage: A Systematic Review.
PubMed 文献 · Ultrasound Med Biol · 2025-08-17

本系统综述评估人工智能驱动的床旁超声(POCUS)系统检测和估计腹部出血的性能。检索2014至2024年Scopus、PubMed、EMBASE和Web of Science,纳入7项研究,图像样本量94至6608幅,患者数78至864例创伤患者。YOLOv3、U-Net和ResNet50等AI模型敏感度88%至98%、特异度68%至99%,多数研究仅做内部验证,仅1项在不同临床场景的独立数据集上验证。

要点

  • AI驱动POCUS检测腹部出血的敏感度88%至98%、特异度68%至99%。
  • 多数研究仅用内部数据集验证,仅1项在不同临床场景的独立数据集上验证。
  • FAST方案对右上腹尤其是Morison's pouch研究较多,左上腹和盆腔应用仍待探索。

核心结论

  • AI驱动的POCUS系统在检测和估计腹部出血方面显示高诊断准确率,但外部验证有限,限制了对不同人群和成像条件适用性的评估。

研究设计与样本

  • 系统综述,检索Scopus、PubMed、EMBASE和Web of Science(2014-2024年),纳入7项研究,图像样本量94至6608幅,患者数78至864例创伤患者。

关键影像表现/征象

  • AI模型包括YOLOv3、U-Net和ResNet50,多数研究使用2D超声成像。
  • 常用系统包括Philips Lumify和Mindray TE7。
  • FAST方案主要用于评估右上腹尤其是Morison's pouch,该区域为重力依赖区,对早期出血敏感。
  • 左上腹和盆腔等其他腹部区域在AI应用中仍待探索。

诊断标准与关键数值

  • AI模型诊断腹部出血的敏感度范围为88%至98%,特异度范围为68%至99%。
  • 模型性能主要用内部数据集评估,训练和评价在同一数据集上进行。
  • 仅1项研究在不同临床场景获得的独立数据集上验证模型。

临床应用与阅片要点

  • AI驱动POCUS系统可能用于急诊、院前、军事和资源有限环境。
  • 阅片时需注意FAST方案对Morison's pouch以外区域(左上腹、盆腔)的覆盖有限。
  • 液体可能根据损伤机制、患者体位或伤后时间优先积聚于不同区域,AI应用需更广泛的解剖覆盖。

局限性

  • 多数研究仅用内部数据集验证,训练和评价在同一数据集上进行。
  • 仅1项研究在不同临床场景的独立数据集上验证模型。
  • 外部验证有限,限制了对AI模型在不同人群和不同成像条件下适用性的评估。
  • 多数研究依赖2D成像。
  • FAST方案对左上腹和盆腔等区域的应用仍待探索。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Abdominal haemorrhage is a life-threatening condition requiring prompt detection to enable timely intervention. Conventional ultrasound (US) is widely used but is highly operator-dependent, limiting its reliability outside clinical settings. In anatomical regions, in particular Morison's Pouch, US provides a higher detection reliability due to the preferential accumulation of free fluid in dependent areas. Recent advancements in artificial intelligence (AI)-integrated point-of-care US (POCUS) systems show promise for use in emergency, pre-hospital, military, and resource-limited environments. This systematic review evaluates the performance of AI-driven POCUS systems for detecting and estimating abdominal haemorrhage. A systematic search of Scopus, PubMed, EMBASE, and Web of Science (2014-2024) identified seven studies with sample sizes ranging from 94 to 6608 images and patient numbers ranging between 78 and 864 trauma patients. AI models, including YOLOv3, U-Net, and ResNet50, demonstrated high diagnostic accuracy, with sensitivity ranging from 88% to 98% and specificity from 68% to 99%. Most studies utilized 2D US imaging and conducted internal validation, typically employing systems such as the Philips Lumify and Mindray TE7. Model performance was predominantly assessed using internal datasets, wherein training and evaluation were performed on the same dataset. Of particular note, only one study validated its model on an independent dataset obtained from a different clinical setting. This limited use of external validation restricts the ability to evaluate the applicability of AI models across diverse populations and varying imaging conditions. Moreover, the Focused Assessment with Sonography in Trauma (FAST) is a protocol drive US method for detecting free fluid in the abdominal cavity, primarily in trauma cases. However, while it is commonly used to assess the right upper quadrant, particularly Morison's pouch, which is gravity-dependent and sensitive for early haemorrhage its application to other abdominal regions, such as the left upper quadrant and pelvis, remains underexplored. This is clinically significant, as fluid may preferentially accumulate in these areas depending on the mechanism of injury, patient positioning, or time since trauma, underscoring the need for broader anatomical coverage in AI applications. Researchers aiming to address the current reliance on 2D imaging and the limited use of external validation should focus future studies on integrating 3D imaging and utilising diverse, multicentre datasets to improve the reliability and generalizability of AI-driven POCUS systems for haemorrhage detection in trauma care.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Zgool T, Antico M, Edwards C, et al. Point-of-Care Ultrasound Imaging for Automated Detection of Abdominal Haemorrhage: A Systematic Review. Ultrasound Med Biol. 2025. PMID: 40820074. doi:10.1016/j.ultrasmedbio.2025.07.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。