文献速递心血管技术与安全CTPET

通用深度学习衰减校正提高SPECT心肌灌注成像诊断准确性:一项多中心研究

General Purpose Deep Learning Attenuation Correction Improves Diagnostic Accuracy of SPECT MPI: A Multicenter Study.
PubMed 文献 · JACC Cardiovasc Imaging · 2025-08-08

本研究开发深度学习模型在多中心4894例患者中生成模拟SPECT衰减校正图像(DeepAC),并在两个外部队列(746例和320例)验证。第一外部队列中DeepAC的总灌注缺损AUC为0.77,高于非衰减校正的0.73(P<0.001);第二队列中DeepAC定量评分与实际衰减校正评分更接近。结论认为DeepAC改善了阻塞性冠心病的预测性能。

要点

  • DeepAC总灌注缺损AUC 0.77,高于非衰减校正AUC 0.73(P<0.001)。
  • DeepAC定量评分与实际衰减校正评分更接近,优于非衰减校正。
  • 该方法可在不增加设备、成像时间或辐射暴露的情况下提升诊断准确性。

核心结论

  • 在多中心外部队列中,DeepAC改善了阻塞性冠心病的预测性能,可在不增加设备、成像时间或辐射暴露的情况下提升常规SPECT系统的诊断准确性。

研究设计与样本

  • 研究在多中心4894例患者(来自4个中心)中开发深度学习模型生成模拟SPECT衰减校正图像(DeepAC),并在临床试验(NCT01347710)的746例患者(来自72个中心)及另一外部中心的320例患者中进行外部验证。

诊断标准与关键数值

  • 第一外部队列中,阻塞性冠心病定义为左主干冠状动脉狭窄≥50%或其他血管狭窄≥70%;DeepAC总灌注缺损AUC为0.77(95%CI:0.73-0.81),非衰减校正总灌注缺损AUC为0.73(95%CI:0.69-0.77),P<0.001。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) uses computed tomography (CT)-based attenuation correction (AC) to improve diagnostic accuracy. Deep learning (DL) has the potential to generate synthetic AC images, as an alternative to CT-based AC.

OBJECTIVES: This study evaluated whether DL-generated synthetic SPECT images could enhance accuracy of conventional SPECT MPI.

METHODS: Study investigators developed a DL model in a multicenter cohort of 4,894 patients from 4 sites to generate simulated SPECT AC images (DeepAC). The model was externally validated in 746 patients from 72 sites in a clinical trial (A Phase 3 Multicenter Study to Assess PET Imaging of Flurpiridaz F 18 Injection in Patients With CAD; NCT01347710) and in 320 patients from another external site. In the first external cohort, the study assessed the diagnostic accuracy for obstructive coronary artery disease (CAD)-defined as left main coronary artery stenosis ≥50% or ≥70% in other vessels-for total perfusion deficit (TPD). In the latter, the study completed change analysis and compared quantitative scores for AC, DeepAC, and nonattenuation correction (NC) with clinical scores.

RESULTS: In the first external cohort (mean age, 63 ± 9.5 years; 69.0% male), 206 patients (27.6%) had obstructive CAD. The area under the receiver-operating characteristic curve (AUC) of DeepAC TPD (0.77; 95% CI: 0.73-0.81) was higher than the NC TPD (AUC: 0.73; 95% CI: 0.69-0.77; P < 0.001). In the second external cohort, DeepAC quantitative scores had closer agreement with actual AC scores compared with NC.

CONCLUSIONS: In a multicenter external cohort, DeepAC improved prediction performance for obstructive CAD. This approach could enhance diagnostic accuracy in facilities using conventional SPECT systems without requiring additional equipment, imaging time, or radiation exposure.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Shanbhag AD, Miller RJH, Lemley M, et al. General Purpose Deep Learning Attenuation Correction Improves Diagnostic Accuracy of SPECT MPI: A Multicenter Study. JACC Cardiovasc Imaging. 2025. PMID: 40778900. doi:10.1016/j.jcmg.2025.06.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。