文献速递心血管MR

延迟期动态对比增强心脏MRI改善心肌组织特征化

Improved Myocardial Tissue Characterization Using Delayed-Phase Dynamic Contrast-enhanced Cardiac MRI.
PubMed 文献 · Radiol Cardiothorac Imaging · 2025-01-01

本研究在11只再灌注心肌梗死犬中构建延迟期动态对比增强(dDCE)MRI模型,用动态增强后T1图刻画对比剂洗脱过程。dDCE5min与dDCE30min参数无显著差异,合成LGE与标准LGE的梗死面积和透壁度无显著差异,但对比噪声比更高,检测心肌梗死的AUC为0.97(95%CI:0.94,>0.99),敏感度94.4%、特异度96.7%。

要点

  • dDCE5min参数与30分钟洗脱参数无显著差异,提示注药后5分钟内即可完成定量评估。
  • 合成LGE与标准LGE的梗死面积和透壁度无显著差异,但对比噪声比更高(14.62 vs 1.41,P<.01)。
  • 合成LGE检测心肌梗死的AUC为0.97(95%CI:0.94,>0.99),敏感度94.4%、特异度96.7%。

核心结论

  • 所开发的dDCE MRI模型在心肌组织评估中显示出增强病灶对比、定量临床相关生理参数并支持心脏病心肌损伤综合评估的潜力。

研究设计与样本

  • 动物研究,纳入11只再灌注心肌梗死犬(7只雌性),采用动态增强后T1图构建dDCE模型,比较30分钟洗脱过程参数(dDCE30min)与5分钟图像子集参数(dDCE5min),并以注药后15分钟采集的标准LGE为参考比较合成LGE(LGEdDCE)的梗死范围和透壁度。

关键影像表现/征象

  • dDCE30min图显示梗死区细胞外容积高于远端心肌(61.12%±13.65 vs 13.43%±5.00,P=.02)。
  • dDCE30min图显示梗死区毛细血管通透性表面积产物高于远端心肌(5.08 mL×g-1×min-1±4.10 vs 0.42 mL×g-1×min-1±0.55,P=.02)。
  • LGEdDCE与LGEstandard的LGE面积无显著差异(30.65%±11.94 vs 30.66%±11.94,P=.99)。
  • LGEdDCE与LGEstandard的透壁度无显著差异(54.87%±15.57 vs 53.27%±15.98,P=.06)。
  • LGEdDCE的对比噪声比高于LGEstandard(14.62±13.03 vs 1.41±0.97,P<.01)。

诊断标准与关键数值

  • LGEdDCE检测心肌梗死的AUC为0.97(95%CI:0.94,>0.99),敏感度94.4%,特异度96.7%。
  • dDCE5min参数与dDCE30min参数比较,所有P>.05,无显著差异证据。

临床应用与阅片要点

  • dDCE模型可在注药后5分钟内生成合成LGE,其梗死面积和透壁度与15分钟标准LGE无显著差异且对比噪声比更高。
  • dDCE30min可定量梗死区细胞外容积和毛细血管通透性表面积产物,梗死区均高于远端心肌。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To evaluate the performance of a delayed-phase dynamic contrast-enhanced (dDCE) MRI model in quantitative assessment of myocardial tissue physiology and late gadolinium enhancement (LGE) within 5 minutes after contrast material injection in reperfused myocardial infarction (MI). Materials and Methods This animal study included 11 canines (seven female) with reperfused MI. A dDCE model using dynamic postcontrast T1 maps was adopted to depict an unbiased contrast material washout process. The dDCE parameters derived from the 30-minute contrast material washout process (dDCE30min) and a 5-minute image subset (dDCE5min) were compared. LGE images were synthesized from the dDCE5min maps (LGEdDCE) and compared LGE extent and transmurality with the standard LGE images acquired at 15 minutes after contrast material injection (LGEstandard). Statistical analyses used paired tests for dependent group comparisons. Results The dDCE30min map demonstrated that extravascular extracellular volume and capillary permeability surface area product were higher in MI regions than in remote myocardium (61.12% ± 13.65 [SD] vs 13.43% ± 5.00; P = .02; 5.08 mL × g-1 × min-1 ± 4.10 vs 0.42 mL × g-1 × min-1 ± 0.55; P = .02, respectively). There was no evidence of differences between dDCE5min parameters and dDCE30min parameters (all P > .05). There was also no evidence of a difference between LGEdDCE and LGEstandard in LGE area (30.65% ± 11.94 vs 30.66% ± 11.94; P = .99) or transmurality (54.87% ± 15.57 vs 53.27% ± 15.98; P = .06), but LGEdDCE demonstrated a higher contrast-to-noise ratio (14.62 ± 13.03 vs 1.41 ± 0.97; P < .01). The area under the receiver operating characteristic curve of MI detection using LGEdDCE was 0.97 (95% CI: 0.94, >0.99), with 94.4% sensitivity and 96.7% specificity. Conclusion The developed dDCE MRI model for myocardial tissue assessment shows potential to enhance lesion contrast, quantify clinically relevant physiologic parameters, and support comprehensive evaluation of myocardial injury in heart disease. Keywords: Dynamic Contrast-enhanced MRI, Myocardial Infarction, MRI, Pharmacokinetics, Ischemic Heart Disease Supplemental material is available for this article. © RSNA, 2025.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Huang LT, Zhang X, Li X, et al. Improved Myocardial Tissue Characterization Using Delayed-Phase Dynamic Contrast-enhanced Cardiac MRI. Radiol Cardiothorac Imaging. 2025. PMID: 40874838. doi:10.1148/ryct.240393

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。