子痫前期胎儿肺动脉多普勒动态:加速时间、射血时间、PAT/ET比值及不良新生儿肺部结局的预测
前瞻性病例对照研究纳入120例单胎妊娠(子痫前期60例、血压正常对照60例),于2025年3月至6月在Ankara Etlik City Hospital随访,使用Voluson E10系统测量胎儿主肺动脉多普勒参数。子痫前期组PAT/ET比值和加速时间均显著低于对照组,复合不良肺部结局发生率显著更高;PAT/ET<0.180预测复合不良肺部结局的敏感度为78.5%、特异度为63.0%、AUC为0.760。作者认为胎儿主肺动脉多普勒参数可能作为子痫前期妊娠新生儿呼吸系统疾病的非侵入性预测指标。
要点
- 子痫前期组胎儿主肺动脉PAT/ET比值0.180±0.09显著低于对照组0.240±0.07(P<.001)。
- 子痫前期组加速时间44.1±18.0 ms显著短于对照组57.1±13.2 ms(P<.001)。
- PAT/ET<0.180预测复合不良肺部结局的AUC为0.760,敏感度78.5%,特异度63.0%。
核心结论
- 胎儿主肺动脉多普勒参数尤其是PAT/ET和AT可能作为子痫前期妊娠新生儿呼吸系统疾病的非侵入性预测指标,将其纳入常规产前监测可能支持及时围产期干预并改善新生儿结局。
研究设计与样本
- 前瞻性病例对照研究,纳入120例单胎妊娠(子痫前期60例、血压正常对照60例),于2025年3月至6月在Ankara Etlik City Hospital随访,使用Voluson E10系统行多普勒超声检查。
关键影像表现/征象
- 主肺动脉多普勒波形在胸部轴位或矢状位切面记录,PAT/ET和AT由三个心动周期平均值计算。
- 子痫前期组主肺动脉搏动指数和阻力指数均高于对照组。
- 子痫前期组复合不良肺部结局发生率为31.6%,显著高于对照组的11.6%(P<.001)。
诊断标准与关键数值
- 复合不良肺部结局定义为至少存在以下之一:呼吸窘迫综合征、新生儿暂时性呼吸增快、需要持续气道正压通气或机械通气、或新生儿重症监护室入住。
- PAT/ET<0.180预测复合不良肺部结局:敏感度78.5%,特异度63.0%,AUC为0.760。
- AT<45.5 ms预测复合不良肺部结局:敏感度75.3%,特异度63.0%,AUC为0.749。
临床应用与阅片要点
- 作者认为胎儿主肺动脉多普勒参数尤其是PAT/ET和AT可能作为子痫前期妊娠新生儿呼吸系统疾病的非侵入性预测指标。
- 作者认为将这些指标纳入常规产前监测可能支持及时围产期干预并改善新生儿结局。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate the predictive value of fetal main pulmonary artery (MPA) Doppler parameters, including acceleration time (AT) and the acceleration time-to-ejection time ratio (PAT/ET), for composite adverse pulmonary outcomes (CAPO) in pregnancies complicated by preeclampsia.
METHODS: This prospective case-control study included 120 singleton pregnancies (60 with preeclampsia and 60 normotensive controls) followed at Ankara Etlik City Hospital between March and June 2025. Doppler ultrasonography was performed using a Voluson E10 system. MPA Doppler waveforms were recorded in an axial or sagittal thoracic view, and PAT/ET and AT were calculated from three averaged cardiac cycles. CAPO was defined as the presence of at least one of the following: respiratory distress syndrome (RDS), transient tachypnea of the newborn (TTN), need for CPAP or mechanical ventilation, or NICU admission.
RESULTS: The preeclampsia group exhibited significantly lower PAT/ET ratios (0.180 ± 0.09 vs 0.240 ± 0.07, P < .001) and shorter AT (44.1 ± 18.0 ms vs 57.1 ± 13.2 ms, P < .001), along with higher MPA PI and RI values. CAPO incidence was significantly higher in the preeclampsia group (31.6 vs 11.6%, P < .001). ROC analysis demonstrated that PAT/ET <0.180 predicted CAPO with 78.5% sensitivity, 63.0% specificity, and an AUC of 0.760. Similarly, AT <45.5 ms yielded 75.3% sensitivity, 63.0% specificity, and an AUC of 0.749.
CONCLUSION: Fetal MPA Doppler parameters, particularly PAT/ET and AT, may serve as noninvasive predictors of neonatal respiratory morbidity in preeclamptic pregnancies. Incorporating these indices into routine antenatal surveillance could support timely perinatal interventions and improve neonatal outcomes.
引用
- Dayanan R, Bulan DD, Ozkan MA, et al. Fetal Pulmonary-Artery Doppler Dynamics in Preeclampsia: Acceleration Time, Ejection Time, PAT/ET Ratio, and Prediction of Adverse Neonatal Pulmonary Outcome. J Ultrasound Med. 2025. PMID: 40810389. doi:10.1002/jum.70031
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。