神经放射科医师对人工智能/机器学习驱动软件生成的真实世界CT灌注成像图报告的影响
该回顾性单中心队列研究纳入132例疑似急性缺血性卒中患者,评估AI软件生成CTP图的可报告率及神经放射科医师解读的影响。AI图无伪影可报告率为65.2%,经神经放射科医师审核后升至87.9%,且CTP结果使CT血管成像期信心评分显著提高。
要点
- AI生成的CTP图无伪影可报告率为65.2%,经神经放射科医师审核后升至87.9%。
- 运动参数和对比剂峰值时间距离是无伪影CTP图的關鍵预测因素。
- CTP结果使CT血管成像期的报告信心评分显著提高。
核心结论
- 神经放射科医师通过解读和校正AI处理图,对提高CTP可靠性具有不可或缺的作用。
研究设计与样本
- 回顾性单中心队列研究,2023年6月至12月于综合性卒中中心纳入132例疑似急性缺血性卒中患者,均行AI软件CTP检查,以RapidAI初分析,再由经验丰富的神经放射科医师验证调整;统计方法包括logistic回归和F1评分。
关键影像表现/征象
- AI软件生成的CTP图无伪影可报告率为65.2%,经神经放射科医师审核后可报告率升至87.9%。
- 无伪影CTP图的关键预测因素包括运动参数和对比剂峰值时间距离。
- CTP结果可视化后,CT血管成像期的信心评分显著向更高分偏移。
临床应用与阅片要点
- AI生成的CTP图需经神经放射科医师审核校正后再报告,以提升可报告率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: According to the guideline, CT perfusion should be read and analyzed by using computer-aided software. This study evaluates the efficacy of artificial intelligence (AI)/machine learning-driven software in CTP imaging and the effect of neuroradiologists' interpretatios on these automated results.
MATERIALS AND METHODS: We conducted a retrospective, single-center cohort study from June to December 2023 at a comprehensive stroke center. A total of 132 patients suspected of having acute ischemic stroke underwent CTP using AI software. RapidAI was used for the initial analysis, with subsequent validation and adjustments made by experienced neuroradiologists. The rate of CTP marked as "nonreportable," "reportable," and "reportable with correction" by neuroradiologists was recorded. The degree of confidence in the report of basal and angio-CT scans was assessed before and after CTP visualization. Statistical analysis included logistic regression and F1 score assessments to evaluate the predictive accuracy of AI-generated CTP maps.
RESULTS: The study found that CTP maps derived from AI software were reportable in 65.2% of cases without artifacts and improved to 87.9% reportable cases when reviewed by neuroradiologists. Key predictive factors for artifact-free CTP maps included motion parameters and the timing of contrast peak distances. There was a significant shift to higher confidence scores of the angiographic phase of CT after the results of CTP.
CONCLUSIONS: Neuroradiologists play an indispensable role in improving the reliability of CTP by interpreting and correcting AI-processed maps.
引用
- De Rubeis G, Stasolla A, Piccioli C, et al. The Impact of a Neuroradiologist on the Report of a Real-World CT Perfusion Imaging Map Derived from Artificial Intelligence/Machine Learning-Driven Software. AJNR Am J Neuroradiol. 2026. PMID: 40846648. doi:10.3174/ajnr.A8979
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。