基于解剖引导重建的双回波钠-23 MRI 绘制区域脑总钠浓度:迈向更高的准确性与精密度
研究纳入34名健康受试者,在3T临床MRI扫描仪上用双调谐(1H-23Na)鸟笼线圈采集23Na与1H图像,采用解剖引导重建(AGR)并与标准重建(SR)比较区域脑总钠浓度(TSC)。AGR在WM腐蚀实验中TSC趋于稳定、PVE减低,灰白质TSC分离更大,且WM与皮层下GM的TSC方差更小。
要点
- AGR较SR减低部分容积效应,WM腐蚀超过1体素后TSCAGR趋于稳定而TSCSR随腐蚀增加而下降。
- AGR下灰白质TSC分离更大:GM TSCAGR=48.6±4.9 mmol/L,WM TSCAGR=30.5±2.8 mmol/L。
- AGR在WM与皮层下GM的TSC方差小于SR。
核心结论
- AGR通过减低非皮层脑区的PVE与TSC方差,有助于健康人脑的钠定量,所建立的脑区TSC正常值为理解神经疾病中23Na代谢与稳态紊乱奠定基础。
研究设计与样本
- 34名健康受试者,使用3T临床MRI扫描仪与双调谐(1H-23Na)鸟笼线圈,23Na图像采用twisted projection imaging序列(TR=100 ms,TE1/TE2=0.5/5 ms),1H图像采用标准T1加权MPRAGE序列;AGR正则化参数βr=0.67、2.0、6.0,基线对照为标准重建(SR,采用补偿非均匀采样的regridding算法);采用仅噪声背景与玻璃体区域的内部线性校准计算ROI的TSC,ROI包括脑叶皮层GM、皮层下(含海马、尾状核、苍白球、壳核与丘脑)、胼胝体及全脑WM;采用多变量方差分析进行Bonferroni校正的两两比较,显著性水平P<.05。
关键影像表现/征象
- WM腐蚀实验显示TSCAGR在WM腐蚀超过1体素后趋于稳定,而TSCSR随腐蚀增加而下降,提示AGR图像PVE减低。
- AGR较SR显示灰质与白质之间TSC分离更大:GM TSCSR=49.2±4.6 mmol/L、WM TSCSR=38.1±3.0 mmol/L,GM TSCAGR=48.6±4.9 mmol/L、WM TSCAGR=30.5±2.8 mmol/L。
- TSCAGR在WM与皮层下GM的方差小于TSCSR。
诊断标准与关键数值
- 区域脑总钠浓度(TSC)以仅噪声背景与玻璃体区域行内部线性校准后计算。
- AGR正则化参数βr取0.67、2.0与6.0。
- GM TSCSR=49.2±4.6 mmol/L、WM TSCSR=38.1±3.0 mmol/L;GM TSCAGR=48.6±4.9 mmol/L、WM TSCAGR=30.5±2.8 mmol/L。
- 统计采用多变量方差分析Bonferroni校正两两比较,显著性水平P<.05。
临床应用与阅片要点
- AGR可减低非皮层脑区TSC的部分容积效应与方差,阅片与定量报告时可关注灰白质TSC分离度。
- WM腐蚀实验显示AGR在腐蚀超过1体素后TSC稳定,SR则随腐蚀增加而下降,提示SR的WM TSC受PVE影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Sodium (23Na) MRI provides unique information about ionic homeostasis in the brain. However, in vivo quantification of regional brain sodium is highly challenging due to low SNR and limited spatial resolution. Here, we use our novel anatomically guided reconstruction (AGR) method to overcome these challenges and enable precise quantification of regional brain total sodium concentration (TSC).
MATERIALS AND METHODS: Thirty-four healthy subjects were studied by using a 3T clinical MRI scanner with a dual-tuned (1H-23Na) birdcage coil. 23Na images were acquired by using a twisted projection imaging sequence (TR = 100 ms, TE1/TE2 = 0.5/5 ms), while proton (1H) images were obtained with a standard T1-weighted MPRAGE sequence. AGR was performed with regularization parameters βr = 0.67, 2.0, and 6.0. As a baseline comparison, standard reconstruction (SR) was also performed by using a regridding algorithm with compensation for nonuniform sampling. To assess partial volume effects (PVEs) on the reconstruction methods, an erosion experiment was conducted. Internal linear calibration using noise-only background and vitreous humor regions was applied to calculate TSC in ROIs including lobar cortical GM, subcortical (including hippocampus, caudate, pallidum, putamen and thalamus), callosal, and whole-brain WM. Bonferroni-corrected pair-wise comparison was performed by using Multivariate Analysis of Variance at a significance level P < .05.
RESULTS: The WM erosion experiments confirmed that TSCAGR was stabilized beyond 1-voxel erosion in the WM, but TSCSR was decreasing with erosion increasing, showing a reduced PVE in the AGR images. AGR also shows greater separation in TSC between GM and WM compared with SR (GM TSCSR = 49.2 ± 4.6 mmol/L, WM TSCSR = 38.1 ± 3.0 mmol/L; GM TSCAGR = 48.6 ± 4.9 mmol/L, WM TSCAGR = 30.5 ± 2.8 mmol/L). We also found smaller variance of TSCAGR in WM and GMsubcortical compared with TSCSR.
CONCLUSIONS: The AGR helps sodium quantification in healthy human brains by reducing the PVE and variance of TSC in noncortical brain regions. Our normative values of TSC in the brain regions set the stage to better understand derangements of 23Na metabolism and homeostasis in neurologic disease.
引用
- Alivar A, Schramm G, Qian Y, et al. Mapping Regional Brain Total Sodium Concentration Using Anatomically Guided Reconstruction of Dual-Echo Sodium-23 MRI: Moving toward Improved Accuracy and Precision. AJNR Am J Neuroradiol. 2026. PMID: 40854686. doi:10.3174/ajnr.A8984
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。