文献速递神经技术与安全CT

基于用户选择层面的定位与对称技术自动检测头颅CT中线移位

Automated Midline Shift Detection in Head CT Using Localization and Symmetry Techniques Based on User-Selected Slice.
PubMed 文献 · AJNR Am J Neuroradiol · 2025-09-02

研究利用981例患者头颅CT,手动选取含侧脑室的单层图像,其中400例标注侧脑室与颅骨轴线,训练基于YOLO的AI模型在剩余581例中检测中线移位。模型区分正常/轻度与中度/重度中线移位的AUC为0.79,敏感度0.73,特异度0.72。作者认为该模型可识别并分层临床显著的中线移位,有望作为未来临床整合流程的基础,标记紧急检查以加速审核。

要点

  • 模型区分正常/轻度与中度/重度中线移位的AUC为0.79,敏感度0.73,特异度0.72。
  • 模型可识别侧脑室和大脑中线,并在不同病理中分层临床显著的中线移位。
  • 严重病例中占位效应常使透明隔消失,无法作为参考标志点。

核心结论

  • 作者开发的AI模型能可靠识别侧脑室和大脑中线,并准确识别和分层临床显著与紧急的中线移位与非紧急病例。

研究设计与样本

  • 使用本机构981例具有广泛脑病理的患者CT扫描,从每例CT中主要根据侧脑室存在手动选择单层图像,使用Roboflow标注其中400例的侧脑室和颅骨轴线中线,基于You Only Look Once目标检测系统训练AI模型,在剩余581例CT的单层图像中识别中线移位。

诊断标准与关键数值

  • 区分正常和轻度与中度和重度中线移位的AUC为0.79,敏感度0.73,特异度0.72。

临床应用与阅片要点

  • 作者认为该模型可作为未来临床整合方法的基础,用于标记紧急检查以加速审核,从而在必要时促进更及时的治疗。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Midline shift (MLS) is an intracranial pathology characterized by the displacement of brain parenchyma across the skull's midsagittal axis, typically caused by mass effect from space-occupying lesions or traumatic brain injuries. Prompt detection of MLS is crucial, because delays in identification and intervention can negatively impact patient outcomes. The gap we have addressed in this work is the development of a deep learning algorithm that encompasses the full severity range from mild to severe cases of MLS. Notably, in more severe cases, the mass effect often effaces the septum pellucidum, rendering it unusable as a fiducial point of reference.

MATERIALS AND METHODS: We sought to enable rapid and accurate detection of MLS by leveraging advances in artificial intelligence (AI). Using a cohort of 981 patient CT scans with a breadth of cerebral pathologies from our institution, we manually chose an individual slice from each CT scan primarily based on the presence of the lateral ventricles and annotated 400 of these scans for the lateral ventricles and skull-axis midline by using Roboflow. Finally, we trained an AI model based on the You Only Look Once object detection system to identify MLS in the individual slices of the remaining 581 CT scans.

RESULTS: When comparing normal and mild cases to moderate and severe cases of MLS detection, our model yielded an area under the curve of 0.79 with a sensitivity of 0.73 and specificity of 0.72 indicating our model is sensitive enough to capture moderate and severe MLS and specific enough to differentiate them from mild and normal cases.

CONCLUSIONS: We developed an AI model that reliably identifies the lateral ventricles and the cerebral midline across various pathologies in patient CT scans. Most importantly, our model accurately identifies and stratifies clinically significant and emergent MLS from nonemergent cases. This could serve as a foundational element for a future clinically integrated approach that flags urgent studies for expedited review, potentially facilitating more timely treatment when necessary.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Banayan NE, Shalu H, Hatzoglou V, et al. Automated Midline Shift Detection in Head CT Using Localization and Symmetry Techniques Based on User-Selected Slice. AJNR Am J Neuroradiol. 2025. PMID: 40835418. doi:10.3174/ajnr.A8767

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。