文献速递神经MR

急性缺血性卒中最终梗死核心的pCASL预测价值:一项观察性单中心研究

Predictor value of pCASL maps on final core in acute ischemic stroke: an observational single‑center study.
PubMed 文献 · Neuroradiology · 2025-08-14

回顾性纳入627例连续急性缺血性卒中患者,其中349例接受DWI和pCASL的MRI方案评估,pCASL预测最终梗死的诊断准确率为84.8%;前循环灌注缺损中DWI对不可存活组织高度可靠,pCASL倾向于高估风险组织但完全重叠率高。

要点

  • DWI-pCASL方案预测最终梗死的诊断准确率为84.8%。
  • 前循环灌注缺损中DWI对不可存活组织高度可靠。
  • pCASL倾向于高估风险组织,可能纳入良性少血区。

核心结论

  • DWI-pCASL方案具有高度可靠的预后准确率,pCASL能可靠识别总低灌注区,但许多病例中高估风险组织并倾向于纳入良性少血区。

研究设计与样本

  • 回顾性观察性单中心研究,连续纳入627例急性缺血性卒中患者,其中349例接受基于MRI的方案(包括pCASL和DWI),用于再灌注治疗选择。

关键影像表现/征象

  • 前循环灌注缺损中,DWI在临床-仪器结局良好的患者中对不可存活组织高度可靠。
  • pCASL在结局不良患者中倾向于高估风险组织,但与最终梗死的完全重叠率较高。
  • 既往评估的CT方案预后准确率较低,CT灌注使用达峰时间同时高估了不可存活组织和风险组织。

诊断标准与关键数值

  • DWI-pCASL方案预测最终梗死的诊断准确率为84.8%。
  • 不可存活组织与最终梗死的相关性在临床-放射学结局良好的患者中最佳。
  • 风险组织与最终梗死的相关性在未治疗患者和治疗失败者中更好。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The three-compartment model of acute ischemic stroke (AIS) includes non-viable tissue (NVT), tissue at risk (TAR), and benign oligoemia. After assessing a multimodal computed tomography (CT)-based protocol, we assessed a hyperacute stroke imaging protocol with magnetic resonance imaging (MRI), aiming to better characterize the reliability of the two methods in predicting follow-up infarction.

METHODS: We retrospectively reviewed 627 consecutive AIS patients evaluated for the selection for reperfusive treatments at comprehensive stroke center. We employed an MRI-based protocol for proper patient selection, including pseudocontinuous arterial spin labeling (pCASL) and diffusion-weighted imaging (DWI). To assess prognostic accuracy of pCASL maps in predicting final infact, we assumed the best correlation between NVT and final infarct in patients with favorable clinico-radiological outcomes. On the other hand, the TAR should better correlate with final infarct in untreated patients and in treatment failure.

RESULTS: We recruited 349 patients undergoing MRI-based protocol with DWI and pCASL, showing diagnostic accuracy of 84.8%. In anterior circulation perfusion deficit, DWI was highly reliable for NVT in patients with favorable clinical-instrumental outcomes. PCASL tended to overestimate TAR in patients with unfavorable outcome, but the rate of complete overlap with the final infarct was high. The previously assessed CT-based protocol showed a lower prognostic accuracy, as the CT-perfusion using time-to-maximum overestimated both the NVT and the TAR.

CONCLUSIONS: We found a highly reliable prognostic accuracy for DWI-pCASL. Even if pCASL proved reliable to identify the area of total hypoperfusion, there was an overestimation of TAR in many cases, with a tendency to incorporate the benign oligoemia.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Giammello F, Tessitore A, Grillo F, et al. Predictor value of pCASL maps on final core in acute ischemic stroke: an observational single‑center study. Neuroradiology. 2025. PMID: 40810815. doi:10.1007/s00234-025-03721-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。