文献速递神经头颈CT

推进神经血管成像:头颈部超高分辨率光子计数探测器CT血管造影重建核与量子迭代重建的优化

Advancing Neurovascular Imaging: Optimization of Reconstruction Kernel and Quantum Iterative Reconstruction for Ultra-high-resolution Photon-Counting Detector CT Angiography of the Head and Neck.
PubMed 文献 · Acad Radiol · 2025-08-05

该前瞻性单中心研究纳入18例颅内动脉瘤患者,在临床光子计数探测器CT上以超高分辨率模式行头颈部CT血管造影,评估6种神经血管重建核(Hv48-89)与量子迭代重建1-4级的组合。定量分析确定Hv56、Hv64、Hv72三种核表现最佳,定性分析显示各核均一致偏好量子迭代重建4级(P<0.001),Hv72最常被偏好但图像伪影发生率较高。作者结论认为Hv72核联合量子迭代重建4级为所评估配置中的最佳组合。

要点

  • 定性分析中各重建核均一致偏好量子迭代重建4级(P<0.001)。
  • Hv72最常被偏好,但图像伪影发生率高于其他重建核。
  • 动脉瘤穹顶测量读者间可靠性高(超高分辨率图像上尤甚),瘤颈测量变异性较大。

核心结论

  • Hv72核联合量子迭代重建4级为所评估配置中的最佳CT血管造影参数组合。
  • 研究结果可为光子计数探测器CT神经血管成像的方案优化提供参考。

研究设计与样本

  • 前瞻性单中心研究,纳入18例颅内动脉瘤患者(平均年龄64.3岁±15[标准差],5名男性)。
  • 在临床光子计数探测器CT扫描仪上以超高分辨率模式采集头颈部CT血管造影。
  • 图像采用6种强度的专用神经血管重建核(Hv48-89)与量子迭代重建1-4级进行重建。

关键影像表现/征象

  • 定量分析确定Hv56、Hv64、Hv72三种重建核表现最佳。
  • 定性分析显示每个评估类别中所有重建核均一致偏好量子迭代重建4级(P<0.001)。
  • Hv72最常被偏好,但与其他重建核相比图像伪影发生率更高。

诊断标准与关键数值

  • 图像噪声、对比噪声比和血管锐度在所有重建图像上测定。
  • 定性图像质量由三名读者采用5点李克特量表评估表现最佳的重建图像。
  • 动脉瘤穹顶和瘤颈尺寸由两名读者独立测量以评估读者间可靠性;穹顶测量读者间可靠性高(超高分辨率图像上尤甚),瘤颈测量变异性较大。

临床应用与阅片要点

  • 作者结论认为Hv72核联合量子迭代重建4级为所评估配置中的最佳组合,结果可为光子计数探测器CT神经血管成像方案优化提供参考。
  • Hv72虽最常被偏好,但图像伪影发生率高于其他重建核。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To find the optimal reconstruction parameters for ultra-high-resolution (UHR) photon-counting detector CT (PCD-CT) angiography of the head and neck, with a special focus on imaging intracranial aneurysms.

MATERIAL AND METHODS: 18 patients with intracranial aneurysms were prospectively enrolled in this single-center study. CT angiograms were acquired in UHR mode on a clinical PCD-CT scanner. Images were reconstructed with six strength levels of a dedicated neurovascular kernel (Hv48-89) and with quantum iterative reconstruction (QIR) levels 1-4. Image noise, contrast-to-noise ratio, and vessel sharpness were determined for all reconstructions. Qualitative image quality was assessed by three readers using a 5-point Likert scale, for the best-performing reconstructions. Aneurysm dome and neck sizes were independently measured by two readers to assess inter-reader reliability.

RESULTS: 18 patients (mean age, 64.3 years ± 15 [SD], 5 men,) were evaluated. Three kernels (Hv56, Hv64, Hv72) were identified as best performing in the quantitative analysis. The qualitative analysis demonstrated a consistent preference for QIR level 4 across all kernels in each evaluated category (P<0.001). Hv72 was the most frequently preferred, although it exhibited a higher incidence of image artifacts compared to the other kernels. Inter-reader reliability was high for dome measurements-especially on UHR images-while neck measurements showed greater variability.

CONCLUSION: Hv72 kernel with QIR level 4 proved to be the optimal combination of CTA parameters among the configurations evaluated. Our results could provide reference for protocol optimization on PCD-CT for neurovascular imaging.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Tóth A, Cho JY, Crow J, et al. Advancing Neurovascular Imaging: Optimization of Reconstruction Kernel and Quantum Iterative Reconstruction for Ultra-high-resolution Photon-Counting Detector CT Angiography of the Head and Neck. Acad Radiol. 2025. PMID: 40753021. doi:10.1016/j.acra.2025.07.033

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。