文献速递神经CTMR

前循环大血管闭塞性缺血性卒中静脉通过时间延长评估的观察者间与观察者内变异性

Interobserver and Intraobserver Variability in the Assessment of Prolonged Venous Transit in Anterior Circulation Large-Vessel Occlusion Ischemic Stroke.
PubMed 文献 · AJNR Am J Neuroradiol · 2025-09-02

回顾性分析194例前循环大血管闭塞性缺血性卒中患者,2名神经放射科医生独立在Tmax灌注图上评估后上矢状窦与窦汇的静脉通过时间延长(PVT)。观察者间一致性为κ=0.79(95%CI 0.69-0.88),观察者内一致性为κ=0.87(95%CI 0.79-0.94),支持PVT作为静脉流出受损的稳定标志物。

要点

  • PVT定性评估在Tmax图上观察者间一致性为κ=0.79(95%CI 0.69-0.88),属高度一致。
  • 观察者内一致性为κ=0.87(95%CI 0.79-0.94),接近完美。
  • 194例中观察者间分类一致178例,观察者内初评与复评不一致11例。

核心结论

  • PVT定性评估显示高度观察者间一致性和接近完美的观察者内可靠性,支持PVT作为AIS-LVO静脉流出受损的一致标志物;未来研究应探索自动化或半定量方法以进一步提高可重复性并增强临床实用性。

研究设计与样本

  • 回顾性研究,纳入194例确诊前循环大血管闭塞性缺血性卒中患者,由2名经委员会认证的神经放射科医生独立审阅治疗前Tmax灌注图评估后上矢状窦和窦汇的PVT,其中1名阅片者至少24周后重复评估;采用Cohen未加权κ系数评估观察者间和观察者内变异性。

关键影像表现/征象

  • PVT评估基于治疗前Tmax灌注图,靶结构为后上矢状窦和窦汇的静脉通过时间延长。

诊断标准与关键数值

  • 观察者间一致性κ=0.79(95%CI 0.69-0.88),194例中分类一致178例。
  • 观察者内一致性κ=0.87(95%CI 0.79-0.94),初评与复评不一致11例。

临床应用与阅片要点

  • 定性评估后上矢状窦和窦汇的Tmax静脉通过时间延长在阅片中具有高度观察者间和观察者内可重复性,可作为AIS-LVO静脉流出受损的影像标志物。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Prolonged venous transit (PVT) on time-to-maximum (Tmax) perfusion maps has been associated with worse outcomes in patients with acute ischemic stroke due to anterior circulation large-vessel occlusion (AIS-LVO). The qualitative nature of PVT assessment introduces potential variability, and its reproducibility has not been systematically evaluated.

MATERIALS AND METHODS: In a retrospective study of patients with confirmed AIS-LVO, 2 board-certified neuroradiologists independently reviewed pretreatment Tmax maps to assess PVT in the posterior superior sagittal sinus and torcula. One reader repeated the assessment after 24 weeks at minimum. Interobserver and intraobserver variability were evaluated with Cohen unweighted κ coefficients.

RESULTS: Among 194 patients, median age was 70 years (interquartile range, 62-79), and 57% were women. Interobserver agreement was substantial (κ = 0.79; 95% CI, 0.69-0.88), reflecting concordant classification in 178 of 194 patients. Intraobserver agreement was also strong (κ = 0.87; 95% CI, 0.79-0.94), with initial and repeat evaluations differing in 11 cases.

CONCLUSIONS: Qualitative PVT assessment demonstrated substantial interobserver and almost perfect intraobserver reliability. These findings support the use of PVT as a consistent marker of impaired venous outflow in AIS-LVO. Future studies should explore automated or semiquantitative methods to further improve reproducibility and enhance clinical utility.