文献速递神经介入DSA

使用带内部导丝支撑的中间导管经桡动脉入路栓塞颅内动脉瘤

Use of an intermediate catheter with internal guide wire support for transradial embolisation of intracranial aneurysms.
PubMed 文献 · Clin Radiol · 2025-07-10

回顾性纳入50例患者共57个颅内动脉瘤,经桡动脉入路使用带内部导丝支撑的中间导管进行栓塞。术后即刻Raymond I级48个(84.2%),随访32例35个动脉瘤中I级32个(91.4%)。作者认为该技术安全有效。

要点

  • 经桡动脉入路使用带内部导丝支撑的中间导管栓塞颅内动脉瘤,技术成功率高。
  • 术后即刻Raymond I级达84.2%,随访I级达91.4%。
  • 仅1例(2%)出现无症状桡动脉闭塞。

核心结论

  • 经桡动脉入路使用带内部导丝支撑的中间导管技术栓塞颅内动脉瘤安全有效。

研究设计与样本

  • 回顾性研究,纳入50例患者(年龄53.2±8.9岁,范围35-82岁)共57个颅内动脉瘤,分析临床资料、治疗及随访结果。

诊断标准与关键数值

  • 术后即刻Raymond I级48个(84.2%)、II级8个(14.0%)、III级1个(1.8%)。
  • 随访35个动脉瘤中Raymond I级32个(91.4%)、II级3个(8.6%)。

临床应用与阅片要点

  • 经右侧桡动脉入路42例(84%),左侧8例(16%)。
  • 单纯弹簧圈栓塞17例(34%),其中单微导管14例(28%)、双微导管3例(6%)。
  • 宽颈动脉瘤支架辅助栓塞40例(80%),其中单微导管36例(72%)、双微导管4例(8%)。
  • 使用0.018英寸导丝46例(92%),0.035英寸导丝4例(8%)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: The aim of this study was to investigate the safety and effect of the technique using an intermediate catheter with internal guide wire support for embolisation of intracranial aneurysms through the transradial access.

MATERIALS AND METHODS: Fifty patients aged 53.2 ± 8.9 (range: 35-82) years with 57 intracranial aneurysms were retrospectively enrolled. The clinical data, treatment, and follow-up outcomes were analysed.

RESULTS: Aneurysm rupture was found in 14 (28%) patients, with aneurysm size ranging 2 to 12 (6.8 ± 1.6) mm. Endovascular treatment was performed through the transradial access on the right in 42 (84%) patients and on the left in 8 (16%). Coil embolisation alone was conducted in 17 (34%) patients, including use of a single microcatheter in 14 (28%) patients and double microcatheters in 3 (6%). Stent-assisted coiling was performed for wide-necked aneurysms in 40 (80%) patients, including use of a microcatheter in 36 (72%) patients and double microcatheters in 4 (8%). A 0.018-inch guide wire was used in 46 (92%) patients, and a 0.035-inch guide wire was used in the rest 4 (8%). Immediately after embolisation, Raymond grade I embolisation was achieved in 48 (84.2%) aneurysms, grade II in 8 (14.0%), and grade III in 1 (1.8%). One (2%) patient had nonsymptomatic occlusion of the punctured radial artery. Thirty-two (64%) patients with 35 (61.4%) aneurysms had angiographic follow-up, including Raymond grade I occlusion in 32 (91.4%) aneurysms and grade II in 3 (8.6%).

CONCLUSION: Use of the intermediate catheter technique with internal guide wire support through the transradial access is safe and effective in endovascular embolisation of intracranial aneurysms.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Xu GQ, Li TX, Zhao TY, et al. Use of an intermediate catheter with internal guide wire support for transradial embolisation of intracranial aneurysms. Clin Radiol. 2025. PMID: 40815901. doi:10.1016/j.crad.2025.107012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。