文献速递外周血管心血管CT

低剂量CT血管成像中基于迭代模型重建显示Adamkiewicz动脉

Adamkiewicz artery visualisation using iterative model-based reconstruction in low-dose computed tomograpyhy (CT) angiography.
PubMed 文献 · Clin Radiol · 2025-07-16

研究纳入45例主动脉瘤或夹层患者,采用低剂量CT方案(100 kVp、20 mA)行256层CT血管成像,比较FBP、iDose4与IMR三种重建算法的图像质量和Adamkiewicz动脉显示情况。IMR的信噪比、对比噪声比及Adamkiewicz动脉显示评分均显著高于iDose4和FBP,可评估Adamkiewicz动脉的检出率也最高。

要点

  • IMR重建的Adamkiewicz动脉显示评分3.6±0.6,高于iDose4的3.1±0.8和FBP的2.6±0.8。
  • IMR可评估Adamkiewicz动脉的检出率为93.3%,高于iDose4的75.6%和FBP的51.1%。
  • 低剂量CT血管成像中IMR的信噪比和对比噪声比均显著优于iDose4和FBP。

核心结论

  • 在低剂量CT血管成像中,IMR算法较iDose4和FBP提供更优的图像质量和Adamkiewicz动脉显示。

研究设计与样本

  • 研究纳入45例主动脉瘤或夹层患者(男性73.3%),采用256层多排CT低剂量方案(100 kVp、20 mA)采集,原始数据分别用FBP、iDose4和IMR重建,由两名观察者盲法分析。

诊断标准与关键数值

  • 定量分析显示主动脉信噪比IMR 35.2±10.2高于iDose4 21.5±4.9和FBP 14.1±3.1(均P<.05),前脊髓动脉相对脊髓的对比噪声比IMR 3.8±0.5高于iDose4 3.1±0.8和FBP 2.6±0.8(均P<.05)。

临床应用与阅片要点

  • 定性分析采用四点量表评估Adamkiewicz动脉显示及其与肋间动脉或腰动脉的连续性,IMR平均评分3.6±0.6高于iDose4 3.1±0.8和FBP 2.6±0.8(P<.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: The use of iterative model-based reconstruction (IMR) for the artery of Adamkiewicz (AKA) visualisation using low-dose computed tomography (CT) angiography remains understudied. Therefore, we aimed to compare the image quality and AKA visualisation using a novel knowledge-based IMR with those using hybrid iterative reconstruction (iDose4) and filtered back projection (FBP) under a low-dose CT protocol.

MATERIALS AND METHODS: Forty-five patients (73.3% male) with aortic aneurysm or dissection who underwent 256-slice multidetector row CT with a low-dose CT protocol (100 kVp and 20 mA) were enrolled. The acquired raw data were reconstructed using FBP, iDose4, and IMR and blindly analysed by two observers. Quantitative analysis assessed signal-to-noise ratio (SNR) of the aorta and contrast-to-noise ratio (CNR) of the anterior spinal artery measurement relative to the spinal cord on multiplanar reformatted images. Qualitative analysis evaluated AKA visualisation and its continuity with the intercostal or lumbar artery using a four-point scale.

RESULTS: In the quantitative analysis, both SNR and CNR of IMR (SNR: 35.2 ± 10.2; CNR: 3.8 ± 0.5) were significantly higher than those of iDose4 (SNR: 21.5 ± 4.9; CNR: 3.1 ± 0.8) and FBP (SNR: 14.1 ± 3.1; CNR: 2.6 ± 0.8) (all P<.05). In the qualitative analysis, the mean AKA visualisation score was also significantly better in IMR (3.6 ± 0.6) than in iDose4 (3.1 ± 0.8) and FBP (2.6 ± 0.8) (P<.05). The prevalence of assessable AKA was the highest in IMR (93.3%), followed by iDose4 (75.6%) and FBP (51.1%).

CONCLUSION: The IMR algorithm provided superior image quality and AKA visualisation compared with iDose4 and FBP when using low-dose CT angiography.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Chun EJ, Kang SR, Nam TH, et al. Adamkiewicz artery visualisation using iterative model-based reconstruction in low-dose computed tomograpyhy (CT) angiography. Clin Radiol. 2025. PMID: 40795451. doi:10.1016/j.crad.2025.107027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。