文献速递神经MRPET

[68]Ga-PSMA-11 PET 与 ASL 灌注 MRI 在胶质母细胞瘤中捕获的生物学信息的相似性

Similarity of Biological Information Captured by [68]Ga-PSMA-11 PET and ASL Perfusion MRI in Glioblastoma.
PubMed 文献 · AJNR Am J Neuroradiol · 2026-02-03

前瞻性纳入 26 例新诊断或复发胶质母细胞瘤患者,共 28 个病灶,比较 [68]Ga-PSMA-11 PET 半定量参数与 ASL 灌注参数的相关性及空间相似性,并分析 PSMA 摄取与免疫组化微血管密度及 PSMA 表达的相关性。结果显示 ASL 与 PSMA PET 参数呈强正相关(P < .001),82% 病灶中 PSMA PET 最高摄取区与 ASL 最高灌注区精确对应,PSMA PET 与 ASL 及 CE MRI 呈中至高度空间相似性;PSMA 摄取与微血管密度及 PSMA 表达均呈正相关。

要点

  • 82%(23/28)病灶中 PSMA PET 最高摄取区与 ASL 最高灌注区精确对应,阅片时可互相参照定位。
  • PSMA PET 与 ASL 空间相似性 mean DSC 0.62(SD 0.17)、mean OV 0.78(SD 0.12),与 CE MRI mean DSC 0.65(SD 0.14)、mean OV 0.79(SD 0.15)。
  • PSMA 摄取与微血管密度及 PSMA 表达均呈正相关,提示可反映 GBM 微血管分布的空间异质性。

核心结论

  • PSMA PET 与 ASL 灌注成像在 GBM 中捕获的生物学信息具有相似性,PSMA PET 的示踪剂摄取可可靠反映 GBM 微血管分布的空间异质性。

研究设计与样本

  • 前瞻性纳入 26 例新诊断或复发胶质母细胞瘤患者(共 28 个病灶),均行常规 MRI、ASL 及 PSMA PET 检查,并以免疫组化微血管密度及 PSMA 表达作为组织学参照。

关键影像表现/征象

  • 全部 28 个病灶均表现为高灌注、中至高度示踪剂摄取及对比增强。
  • 23 个病灶(82%)中 PSMA PET 最高示踪剂摄取区精确位于 ASL 最高灌注区。
  • PSMA PET 与 ASL 的空间相似性 mean DSC 0.62(SD 0.17)、mean OV 0.78(SD 0.12)。
  • PSMA PET 与 CE MRI 的空间相似性 mean DSC 0.65(SD 0.14)、mean OV 0.79(SD 0.15)。

诊断标准与关键数值

  • ASL 与 PSMA PET 半定量参数之间呈强正相关(P < .001)。
  • PSMA 示踪剂摄取与微血管密度及 PSMA 表达均呈正相关。
  • 空间相似性采用 Dice 相似系数(DSC)与重叠体积(OV)评估,PSMA PET 与 ASL 的 mean DSC 为 0.62(SD 0.17)、mean OV 为 0.78(SD 0.12)。
  • PSMA PET 与 CE MRI 的 mean DSC 为 0.65(SD 0.14)、mean OV 为 0.79(SD 0.15)。

临床应用与阅片要点

  • ASL 高灌注区与 PSMA PET 高摄取区高度重叠,阅片时可将两者互相参照以定位肿瘤微血管最丰富区域。
  • PSMA PET 示踪剂摄取可反映 GBM 微血管分布的空间异质性,作者认为这些发现为 PSMA 靶向放射治疗作为抗血管生成治疗策略提供了有力支持。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: The overexpression of prostate-specific membrane antigen (PSMA) in the microvasculature of glioblastoma (GBM), in contrast to its negligible expression in normal brain parenchyma, provides a compelling rationale for using PSMA-targeted radioligands in the diagnosis and radiation therapy of GBM. Arterial spin-labeling (ASL) perfusion imaging, an advanced MRI technique, allows noninvasive assessment of tumor microvascular density and perfusion. This study aimed to investigate the relationship between gallium 68 [68]Ga-PSMA-11 PET and ASL perfusion imaging, as well as the correlation between PSMA tracer uptake and immunohistochemical microvascular indices.

MATERIALS AND METHODS: Twenty-six patients with newly diagnosed or recurrent GBM who underwent conventional MRI, ASL, and PSMA PET were prospectively enrolled. We investigated the correlation between the semiquantitative parameters of ASL and PSMA PET. Spatial similarity and overlap between tumor volumes delineated by contrast-enhanced (CE) MRI, ASL, and PSMA PET were evaluated using Dice Similarity Coefficient (DSC) and overlap volume (OV). Additionally, microvascular density values and PSMA expression levels in the tumor tissue samples were assessed using immunohistochemistry, and their correlation with PSMA tracer uptake was analyzed.

RESULTS: A total of 28 lesions was found in 26 patients, all of whom showed high perfusion, moderate-to-high tracer uptake, and contrast enhancement. In 23 lesions (82%), the areas with the highest tracer uptake on PSMA PET were precisely localized to the regions of the highest perfusion on ASL. A strong positive correlation was found between the parameters derived from ASL and PSMA PET (P < .001). PSMA PET exhibited moderate-to-high spatial similarity and overlap with ASL (mean DSC, 0.62 [SD, 0.17]; mean OV, 0.78 [SD, 0.12]) and with CE MRI (mean DSC, 0.65 [SD, 0.14]; mean OV, 0.79 [SD, 0.15]). Furthermore, a positive correlation was observed between PSMA tracer uptake and both microvascular density and PSMA expression.

CONCLUSIONS: Our results highlight the similarity of biologic information captured by PSMA PET and ASL perfusion imaging in GBM. The tracer uptake observed in PSMA PET can also reliably reflect the spatial heterogeneity of the microvascular distribution of GBM. These findings provide compelling support for PSMA-targeted radiation therapy as an anti-angiogenic therapeutic strategy for patients with GBM, while also advancing our understanding of the mechanisms underlying PSMA tracer uptake.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Han Y, Cui Z, Hu W, et al. Similarity of Biological Information Captured by [68]Ga-PSMA-11 PET and ASL Perfusion MRI in Glioblastoma. AJNR Am J Neuroradiol. 2026. PMID: 40841161. doi:10.3174/ajnr.A8965

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。