基于增强CT的2.5D深度学习预测透明细胞肾细胞癌病理分级:一项多中心研究
该多中心回顾性研究纳入5家医院564例透明细胞肾细胞癌患者,基于动脉期增强CT开发2D、2.5D(三层输入)及影像组学MLP模型预测WHO/ISUP分级。2.5D模型性能最优,训练集AUC 0.959,内部测试集0.879,三个外部验证集AUC分别为0.870、0.862、0.849,外部验证中AUC较MLP模型显著提高。
要点
- 2.5D模型基于动脉期增强CT三层输入,外部验证AUC 0.849–0.870,优于2D和MLP模型。
- 外部验证集中2.5D较MLP的AUC提高0.088–0.150(p<0.05),准确率提高0.075–0.101(p<0.05)。
- 模型用于预测透明细胞肾细胞癌WHO/ISUP病理分级,训练集AUC达0.959。
核心结论
- 基于2.5D CT图像输入的2.5D模型对透明细胞肾细胞癌WHO/ISUP分级表现出 improved 预测性能。
研究设计与样本
- 多中心回顾性研究,纳入5家医院564例透明细胞肾细胞癌患者;中心1和2随机分为训练集(n=283)和内部测试集(n=122),中心3、4、5分别为外部验证集1(n=60)、2(n=38)、3(n=61);开发2D模型、2.5D模型(三层输入)和影像组学多层感知机(MLP)模型,基于动脉期增强CT。
诊断标准与关键数值
- 2.5D模型AUC:训练集0.959(95%CI: 0.9438-0.9738),内部测试集0.879(95%CI: 0.8401-0.9180),外部验证集1为0.870(95%CI: 0.8076-0.9334),外部验证集2为0.862(95%CI: 0.7581-0.9658),外部验证集3为0.849(95%CI: 0.7766-0.9216);对应准确率分别为0.895、0.836、0.827、0.825、0.839。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To develop and validate a deep learning model based on arterial phase-enhanced CT for predicting the pathological grading of clear cell renal cell carcinoma (ccRCC).
MATERIALS AND METHODS: Data from 564 patients diagnosed with ccRCC from five distinct hospitals were retrospectively analyzed. Patients from centers 1 and 2 were randomly divided into a training set (n=283) and an internal test set (n=122). Patients from centers 3, 4, and 5 served as external validation sets 1 (n=60), 2 (n=38), and 3 (n=61), respectively. A 2D model, a 2.5D model (three-slice input), and a radiomics-based multi-layer perceptron (MLP) model were developed. Model performance was evaluated using the area under the curve (AUC), accuracy, and sensitivity.
RESULTS: The 2.5D model outperformed the 2D and MLP models. Its AUCs were 0.959 (95% CI: 0.9438-0.9738) for the training set, 0.879 (95% CI: 0.8401-0.9180) for the internal test set, and 0.870 (95% CI: 0.8076-0.9334), 0.862 (95% CI: 0.7581-0.9658), and 0.849 (95% CI: 0.7766-0.9216) for the three external validation sets, respectively. The corresponding accuracy values were 0.895, 0.836, 0.827, 0.825, and 0.839. Compared to the MLP model, the 2.5D model achieved significantly higher AUCs (increases of 0.150 [p<0.05], 0.112 [p<0.05], and 0.088 [p<0.05]) and accuracies (increases of 0.077 [p<0.05], 0.075 [p<0.05], and 0.101 [p<0.05]) in the external validation sets.
CONCLUSION: The 2.5D model based on 2.5D CT image input demonstrated improved predictive performance for the WHO/ISUP grading of ccRCC.
引用
- Yang Z, Jiang H, Shan S, et al. 2.5D Deep Learning-Based Prediction of Pathological Grading of Clear Cell Renal Cell Carcinoma Using Contrast-Enhanced CT: A Multicenter Study. Acad Radiol. 2025. PMID: 40683765. doi:10.1016/j.acra.2025.06.056
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。