文献速递介入外周血管腹部USDSA

血管内超声在经颈静脉肝内门体分流术创建中的应用:比较传统经颈静脉肝内门体分流术与血管内超声引导下经颈静脉肝内门体分流术的系统综述与Meta分析

Intravascular ultrasound in transjugular intrahepatic portosystemic shunt creation: a systematic review and meta-analysis comparing conventional transjugular intrahepatic portosystemic shunt with intravascular ultrasound -guided transjugular intrahepatic portosystemic shunt.
PubMed 文献 · Br J Radiol · 2025-01-01

该系统综述与Meta分析纳入6项回顾性研究共418例患者(血管内超声引导下经颈静脉肝内门体分流术180例,传统经颈静脉肝内门体分流术238例),比较两种术式的临床与操作获益。结果显示两组技术成功率相似,血管内超声引导下经颈静脉肝内门体分流术显著减少透视时间9.74 min、辐射暴露583.4 mGy、总手术时间21 min、门静脉入路时间15.49 min及对比剂用量69.62 cc(均P < .001),但基于有限研究支持其优势,需进一步前瞻性验证。

要点

  • 血管内超声引导下经颈静脉肝内门体分流术较传统术式显著降低透视时间9.74 min与辐射暴露583.4 mGy(均P < .001)。
  • 血管内超声引导下经颈静脉肝内门体分流术较传统术式缩短总手术时间21 min与门静脉入路时间15.49 min(均P < .001)。
  • 血管内超声引导下经颈静脉肝内门体分流术较传统术式减少对比剂用量69.62 cc(P < .001),技术成功率相似。

核心结论

  • 基于有限数量的研究,这些发现支持血管内超声引导下经颈静脉肝内门体分流术作为提高操作效率、减少辐射暴露、手术时间和对比剂用量而不影响成功率的更优技术;其获益在复杂解剖或高风险患者中尤为明显。

研究设计与样本

  • 系统综述与Meta分析,检索Medline和Google Scholar截至2024年8月30日,纳入6项回顾性研究共418例患者(血管内超声引导下经颈静脉肝内门体分流术180例,传统经颈静脉肝内门体分流术238例),采用匹配比较组分析结局。

诊断标准与关键数值

  • 血管内超声引导下经颈静脉肝内门体分流术较传统术式透视时间减少9.74 min(P < .001)。
  • 血管内超声引导下经颈静脉肝内门体分流术较传统术式辐射暴露减少583.4 mGy(P < .001)。
  • 血管内超声引导下经颈静脉肝内门体分流术较传统术式总手术时间缩短21 min(P < .001)。
  • 血管内超声引导下经颈静脉肝内门体分流术较传统术式门静脉入路时间缩短15.49 min(P < .001)。
  • 血管内超声引导下经颈静脉肝内门体分流术较传统术式对比剂用量减少69.62 cc(P < .001)。

临床应用与阅片要点

  • 作者认为血管内超声引导下经颈静脉肝内门体分流术在提高操作效率和减少辐射暴露、手术时间及对比剂用量方面可能优于传统技术,尤其适用于复杂解剖或高风险患者。
  • 原文结论指出这些发现支持进一步研究和前瞻性验证。

局限性

  • 原文指出结论基于有限数量的研究。
  • 原文结论提出这些发现支持进一步研究和前瞻性验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This systematic review and meta-analysis evaluate the clinical and procedural benefits of intravascular ultrasound (IVUS)-guided portal vein access during transjugular intrahepatic portosystemic shunt (iTIPS) creation compared to the conventional TIPS (cTIPS) technique.

METHODS: A comprehensive search of Medline and Google Scholar through August 30, 2024, was conducted to identify retrospective studies comparing iTIPS and cTIPS. A total of six studies, involving 418 patients (180 undergoing iTIPS and 238 undergoing cTIPS), met inclusion criteria. Matched comparison groups were used to analyze outcomes.

RESULTS: Technical success rates were similar between iTIPS and cTIPS groups. One study reported a significantly lower complication rate with iTIPS, while three studies found no differences in complications. Notably, iTIPS significantly reduced fluoroscopy time by 9.74 min (P < .001) and radiation exposure by 583.4 mGy (P < .001) compared to cTIPS. The total procedure time and portal venous access time were shorter by 21 min (P < .001) and 15.49 min (P < .001), respectively, with IVUS guidance. Additionally, contrast agent use was 69.62 cc lower (P < .001) in iTIPS cases.

CONCLUSION: Although based on a limited number of studies, these findings support IVUS-guided TIPS as a superior technique for improving procedural efficiency and reducing radiation exposure, procedure times, and contrast agent usage without compromising success rates. Its benefits are particularly pronounced in patients with complex anatomy or heightened risk factors.

ADVANCES IN KNOWLEDGE: IVUS-guided TIPS demonstrates potential procedural and safety advantages over conventional techniques, particularly in anatomically complex or high-risk patients. These findings support further investigation and prospective validation.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Torkian P, Talaie R, Flanagan S, et al. Intravascular ultrasound in transjugular intrahepatic portosystemic shunt creation: a systematic review and meta-analysis comparing conventional transjugular intrahepatic portosystemic shunt with intravascular ultrasound -guided transjugular intrahepatic portosystemic shunt. Br J Radiol. 2025. PMID: 40650929. doi:10.1093/bjr/tqaf158

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。