文献速递儿科影像腹部技术与安全US

探头压力对儿童超声阑尾显示的影响:一项先导研究

The Influence of Probe Pressure on Appendix Visualization in Pediatric Sonography: A Pilot Study.
PubMed 文献 · J Ultrasound Med · 2025-07-02

本研究纳入46例接受常规肾脏超声的儿科门诊患者,采用标准化方案记录探头加压时正常阑尾(基底部和远端)的移动。所有扫描均识别出阑尾,30例扫描记录到阑尾移出视野;识别阑尾所需平均压力低于使阑尾基底部和远端移出视野所需压力,平均皮肤厚度相当,压力及皮肤厚度与阑尾移出视野均无统计学显著相关。作者认为阑尾未显示可能归因于过度超声压力导致器官移位。

要点

  • 识别阑尾所需平均压力低于使阑尾基底部和远端移出视野所需压力。
  • 30例扫描记录到阑尾移出视野,其中12例为整个阑尾移动。
  • 压力及皮肤厚度与阑尾移出视野均无统计学显著相关。

核心结论

  • 尽管施加压力与阑尾移动之间无统计学显著相关,但由于所有阑尾均在低于使大多数阑尾移出视野所需压力的压力下被识别,阑尾未显示可能归因于过度超声压力导致器官移位。

研究设计与样本

  • 先导研究,纳入46例接受常规肾脏超声的儿科门诊患者,采用标准化成像方案,使用力传感器记录压力,在基线、首次识别阑尾时和最大压力时测量皮肤厚度。

关键影像表现/征象

  • 所有扫描均识别出阑尾。
  • 30例扫描记录到阑尾移出视野,其中12例显示整个阑尾移动,11例仅远端阑尾移动,7例仅阑尾基底部移动。
  • 识别阑尾时的平均压力低于阑尾基底部和远端移出视野时的平均压力。
  • 平均皮肤厚度相当。

诊断标准与关键数值

  • 阑尾识别所需最小压力和使阑尾移出视野所需最大压力用力传感器记录。
  • 压力及皮肤厚度与阑尾移出视野均无统计学显著相关。

临床应用与阅片要点

  • 作者认为阑尾未显示可能归因于过度超声压力导致器官移位。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the influence of ultrasound probe pressure on the visualization of the appendix sonographically.

METHODS: Pediatric outpatients undergoing routine renal ultrasound (US) were approached for additional images using a standardized imaging protocol. The movement of the normal appendix (base and distal parts) was documented while applying probe pressure. The minimum pressure required for appendix identification and the maximum pressure required to elicit movement out of the field-of-view were recorded using a force sensor. Skin thickness was measured at baseline, at first appendix identification, and at maximal pressure. Appendiceal locations and peri-appendicular findings were also recorded.

RESULTS: Forty-six US scans were included in the final analysis. The appendix was identified in all scans. Movement out of the field-of-view was documented in 30 scans, of which 12 showed movement of the entire appendix, 11 of the distal appendix, and seven of the appendicular base only. The mean pressure was lower when the appendix was identified than when its base and distal part moved out of the field-of-view. The mean skin thickness was comparable. Neither pressure nor skin thickness showed a statistically significant correlation with appendix movement out of the field-of-view.

CONCLUSIONS: Despite no statistically significant correlation between the applied pressure and the appendiceal movement, since all the appendices were identified with less pressure than the pressure needed to displace most of them out of the field-of-view, it is possible that the non-visualization of the appendix is attributed to the displacement of the organ due to excessive sonographic pressure.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Ahyad RA. The Influence of Probe Pressure on Appendix Visualization in Pediatric Sonography: A Pilot Study. J Ultrasound Med. 2025. PMID: 40600458. doi:10.1002/jum.16757

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。