研究在3家西班牙大学医院纳入30例疑似脑膜炎且囟门未闭的婴儿(2021至2023年),构建基于Neosonics超声的三阶段深度学习框架:先以血管/非血管模型质控图像,再按脑脊液白细胞计数阈值30 cells/mm3分类,最后用Grad-CAM等可解释AI方法提升透明度。最终16例(6例病例336幅图像、10例对照445幅图像)中,图像级检测精确率93%、准确率92%,患者级准确率94%,以100%敏感度和90%特异度识别6例病例与10例对照,仅1例误分类;结论支持该多阶段深度学习模型用于婴儿脑膜炎无创筛查并可能指导腰椎穿刺需求。

要点

  • 以脑脊液白细胞计数30 cells/mm3为阈值,图像级脑膜炎检测精确率93%、准确率92%。
  • 患者级准确率94%,6例病例与10例对照中敏感度100%、特异度90%,仅1例误分类。
  • 基于Grad-CAM的可解释AI结合熵与标准差等图像统计,提示图像纹理变化与细胞存在相关。

核心结论

  • 本研究支持多阶段深度学习模型用于婴儿脑膜炎无创筛查的有效性,并可能指导腰椎穿刺的需求。

研究设计与样本

  • 采用Neosonics超声技术的前瞻性三阶段深度学习框架研究,纳入30例疑似脑膜炎且囟门未闭的婴儿,来自3家西班牙大学医院,时间范围为2021至2023年。
  • 第一阶段以血管/非血管模型对2194幅图像进行质量控制,聚焦血管识别并手动剔除耦合不良与杂波等伪影图像。
  • 质控后最终队列为16例患者,其中6例病例共336幅图像、10例对照共445幅图像,合计781幅图像进入第二阶段。
  • 第二阶段用深度学习模型按脑脊液白细胞计数阈值30 cells/mm3将图像分为对照或脑膜炎类别;第三阶段整合Grad-CAM可视化等可解释AI方法与图像统计分析。

关键影像表现/征象

  • 通过分析熵与标准差等图像指标,识别出可归因于细胞存在的图像纹理变化。
  • 基于梯度加权类激活映射的可解释AI显著提升了诊断可解释性。

诊断标准与关键数值

  • 以脑脊液白细胞计数30 cells/mm3为分类阈值,将图像分为对照或脑膜炎类别。
  • 图像级脑膜炎检测精确率93%、准确率92%;质量控制准确率96%。
  • 患者级总体准确率94%,识别6例脑膜炎病例与10例对照,敏感度100%、特异度90%,仅1例误分类。

临床应用与阅片要点

  • 该多阶段深度学习框架基于囟门未闭婴儿的高分辨率超声图像,可无创筛查婴儿脑膜炎并可能指导腰椎穿刺的需求。
  • 阅片时可关注Grad-CAM可视化提示区域及熵、标准差等图像统计所反映的纹理变化,作为模型判读的参考。

局限性

  • 最终分析队列仅16例患者(6例病例、10例对照),来源于30例疑似脑膜炎婴儿。
  • 本文结论指出该研究为未来研究和创新铺路,提示仍需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Infant meningitis can be a life-threatening disease and requires prompt and accurate diagnosis to prevent severe outcomes or death. Gold-standard diagnosis requires lumbar puncture (LP) to obtain and analyze cerebrospinal fluid (CSF). Despite being standard practice, LPs are invasive, pose risks for the patient and often yield negative results, either due to contamination with red blood cells from the puncture itself or because LPs are routinely performed to rule out a life-threatening infection, despite the disease's relatively low incidence. Furthermore, in low-income settings where incidence is the highest, LPs and CSF exams are rarely feasible, and suspected meningitis cases are generally treated empirically. There is a growing need for non-invasive, accurate diagnostic methods.

METHODOLOGY: We developed a three-stage deep learning framework using Neosonics ultrasound technology for 30 infants with suspected meningitis and a permeable fontanelle at three Spanish University Hospitals (from 2021 to 2023). In stage 1, 2194 images were processed for quality control using a vessel/non-vessel model, with a focus on vessel identification and manual removal of images exhibiting artifacts such as poor coupling and clutter. This refinement process resulted in a final cohort comprising 16 patients-6 cases (336 images) and 10 controls (445 images), yielding 781 images for the second stage. The second stage involved the use of a deep learning model to classify images based on a white blood cell count threshold (set at 30 cells/mm3) into control or meningitis categories. The third stage integrated explainable artificial intelligence (XAI) methods, such as Grad-CAM visualizations, alongside image statistical analysis, to provide transparency and interpretability of the model's decision-making process in our artificial intelligence-driven screening tool.

RESULTS: Our approach achieved 96% accuracy in quality control and 93% precision and 92% accuracy in image-level meningitis detection, with an overall patient-level accuracy of 94%. It identified 6 meningitis cases and 10 controls with 100% sensitivity and 90% specificity, demonstrating only a single misclassification. The use of gradient-weighted class activation mapping-based XAI significantly enhanced diagnostic interpretability, and to further refine our insights we incorporated a statistics-based XAI approach. By analyzing image metrics such as entropy and standard deviation, we identified texture variations in the images attributable to the presence of cells, which improved the interpretability of our diagnostic tool.

CONCLUSION: This study supports the efficacy of a multi-stage deep learning model for non-invasive screening of infant meningitis and its potential to guide the need for LPs. It also highlights the transformative potential of artificial intelligence in medical diagnostic screening for neonatal health care, paving the way for future research and innovations.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Sial HA, Carandell F, Ajanovic S, et al. Novel Artificial Intelligence-Driven Infant Meningitis Screening From High-Resolution Ultrasound Imaging. Ultrasound Med Biol. 2025. PMID: 40582896. doi:10.1016/j.ultrasmedbio.2025.04.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。