文献速递骨肌MR

仅使用碘对比剂的腕部MR关节造影方案在检测腕内在韧带及三角纤维软骨复合体撕裂中的诊断准确性

Diagnostic accuracy of wrist MR-arthrography protocol using iodinated contrast agent only in the detection of intrinsic wrist ligament and triangular fibrocartilage complex tears.
PubMed 文献 · Skeletal Radiol · 2025-07-29

回顾性纳入39例于关节镜检查前接受仅用碘对比剂腕部MR关节造影的患者,由住院医师和肌骨放射科医师独立阅片并与关节镜对照。肩月骨韧带、月三角韧带及三角纤维软骨复合体撕裂的患病率分别为74%、51%和64%,MR关节造影对各结构撕裂显示较高敏感度与特异度,观察者间及观察者内一致性良好。

要点

  • 仅用碘对比剂行腕部MR关节造影,对肩月骨韧带、月三角韧带及三角纤维软骨复合体撕裂具有较高敏感度和特异度。
  • 三角纤维软骨复合体撕裂的敏感度在住院医师为0.80、肌骨放射科医师为0.96,特异度分别为0.79和0.86。
  • 肩月骨韧带部分撕裂与完全撕裂的MR关节造影与关节镜一致性良好(R1为0.62,R2为0.76)。

核心结论

  • 仅使用碘对比剂的腕部MR关节造影对韧带损伤显示较高敏感度和特异度,作者认为该技术是探索腕部疼痛的一种有意义的选择。

研究设计与样本

  • 回顾性研究,2019年5月至2021年12月纳入39例在关节镜检查前接受仅用碘对比剂腕部MR关节造影的患者,以腕关节镜报告为参考标准,由住院医师(R1)和肌骨放射科医师(R2)独立阅片。

诊断标准与关键数值

  • 肩月骨韧带撕裂:敏感度、特异度、准确度分别为R1 1.00、0.70、0.92,R2 0.90、0.90、0.90。
  • 月三角韧带撕裂:敏感度、特异度、准确度分别为R1 0.90、0.74、0.82,R2 0.90、0.84、0.87。
  • 三角纤维软骨复合体撕裂:敏感度、特异度、准确度分别为R1 0.80、0.79、0.79,R2 0.96、0.86、0.92。

临床应用与阅片要点

  • 作者认为,仅使用碘对比剂的腕部MR关节造影是探索腕部疼痛的一种有意义的选择。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine the diagnostic accuracy of a wrist MR-arthrography (MR-A) protocol using iodinated contrast agent only compared to wrist diagnostic arthroscopy in the detection of tears of intrinsic ligaments and triangular fibrocartilage complex (TFCC).

MATERIALS AND METHODS: This study retrospectively enrolled 39 patients who underwent MR-A using iodinated contrast agent only before arthroscopic examination between May 2019 and December 2021. For each patient, a resident (R1) and an experienced musculoskeletal radiologist (R2) independently reviewed the MR-A dataset. The performance in detecting and characterizing tears of intrinsic ligaments and TFCC was calculated against arthroscopic reports. Intra- and interrater agreements for MR-A were calculated too.

RESULTS: Prevalence of ligament tear was 74% for scapholunate (SL) ligament, 51% for lunotriquetral (LT) ligament and 64% for TFCC. Wrist arthroscopy revealed cartilage lesions in 25.6%. Concerning SL tears, sensitivity, specificity, and accuracy of MR-A were 1.00, 0.70, and 0.92 (R1) and 0.90, 0.90, and 0.90 (R2). For LT tears, sensitivity, specificity, and accuracy were 0.90, 0.74, and 0.82 (R1) and 0.90, 0.84, and 0.87 (R2). Regarding TFCC tears, sensitivity, specificity, and accuracy were 0.80, 0.79, and 0.79 (R1) and 0.96, 0.86, and 0.92 (R2). Concerning SL tear characterization (partial versus complete tear), agreement between MR-A and arthroscopy was good (0.62 [0.42-0.83] for R1; 0.76 [0.60-0.91] for R2). Interobserver and intraobserver agreements for MR-A assessment were respectively good (0.68 [0.56-0.79]) and very good (0.92 [0.86-0.98]).

CONCLUSIONS: MR-arthrography with iodinated contrast agent only displays high sensitivity and specificity for ligamentous injuries, making this technique an interesting option for exploring wrist pain.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Nauwelaers M, El Amiri L, Bierry G, et al. Diagnostic accuracy of wrist MR-arthrography protocol using iodinated contrast agent only in the detection of intrinsic wrist ligament and triangular fibrocartilage complex tears. Skeletal Radiol. 2025. PMID: 40731075. doi:10.1007/s00256-025-04996-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。