SPACE:基于超声造影的肿瘤灌注亚区分析综合评估乳腺肿瘤——一项回顾性与前瞻性多中心队列研究
本研究基于四个学术医学中心2015年9月至2024年10月的乳腺肿瘤超声造影视频,提取像素级时间-强度曲线灌注变量并通过聚类分析生成灌注异质性图,构建结合临床变量、亚区百分比和影像组学评分的联合诊断模型及列线图。共纳入339例肿瘤(回顾性233例、前瞻性106例),亚区2在良性肿瘤中占优势、亚区3在恶性肿瘤中多见,联合模型在训练集、回顾性测试集和前瞻性测试集的AUC分别为0.93、0.82和0.90。
要点
- 亚区分析显示亚区2在良性肿瘤中占优势,亚区3在恶性肿瘤中多见。
- 联合模型在训练集、回顾性测试集和前瞻性测试集的AUC分别为0.93、0.82和0.90。
- 年龄和亚区影像组学评分是独立危险因素。
核心结论
- 所提出的基于超声造影的方法增强了肿瘤灌注动力学的可视化和量化,显著提高了乳腺肿瘤的诊断准确性。
研究设计与样本
- 回顾性-前瞻性队列研究,纳入四个学术医学中心2015年9月至2024年10月的乳腺肿瘤超声造影视频,共339例肿瘤,回顾性数据233例分为训练集和测试集,前瞻性数据106例作为独立测试集。
关键影像表现/征象
- 亚区2在良性肿瘤中占优势。
- 亚区3在恶性肿瘤中多见。
诊断标准与关键数值
- 在59个机器学习模型中,Elastic Net(ENET)(α=0.7)表现最佳。
- 联合模型在训练集、回顾性测试集和前瞻性测试集的AUC分别为0.93、0.82和0.90。
- 年龄和亚区影像组学评分是独立危险因素。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To develop a dynamic contrast-enhanced ultrasound (CEUS)-based method for segmenting tumor perfusion subregions, quantifying tumor heterogeneity, and constructing models for distinguishing benign from malignant breast tumors.
METHODS: This retrospective-prospective cohort study analyzed CEUS videos of patients with breast tumors from four academic medical centers between September 2015 and October 2024. Pixel-based time-intensity curve (TIC) perfusion variables were extracted, followed by the generation of perfusion heterogeneity maps through cluster analysis. A combined diagnostic model incorporating clinical variables, subregion percentages, and radiomics scores was developed, and subsequently, a nomogram based on this model was constructed for clinical application.
RESULTS: A total of 339 participants were included in this bidirectional study. Retrospective data included 233 tumors divided into training and test sets. The prospective data comprised 106 tumors as an independent test set. Subregion analysis revealed Subregion 2 dominated benign tumors, while Subregion 3 was prevalent in malignant tumors. Among 59 machine-learning models, Elastic Net (ENET) (α = 0.7) performed best. Age and subregion radiomics scores were independent risk factors. The combined model achieved area under the curve (AUC) values of 0.93, 0.82, and 0.90 in the training, retrospective, and prospective test sets, respectively.
CONCLUSION: The proposed CEUS-based method enhances visualization and quantification of tumor perfusion dynamics, significantly improving the diagnostic accuracy for breast tumors.
引用
- Fu Y, Chen J, Chen Y, et al. SPACE: Subregion Perfusion Analysis for Comprehensive Evaluation of Breast Tumor Using Contrast-Enhanced Ultrasound-A Retrospective and Prospective Multicenter Cohort Study. Ultrasound Med Biol. 2025. PMID: 40610252. doi:10.1016/j.ultrasmedbio.2025.05.008