射频识别标签放置:是否存在最佳标签与靶病灶距离?
该回顾性队列分析纳入2018至2021年间连续进行的射频识别标签定位切除活检与保乳手术共456个不可触及乳腺病灶(445例患者),中位标签-靶病灶距离4.5 mm,切缘阳性率15.1%。多因素分析显示标签-靶病灶距离与保乳手术切缘阳性率及手术标本体积均无显著关联,保乳手术切缘阳性的唯一显著预测因素为最终病理导管原位癌(p < 0.001)。
要点
- 标签-靶病灶距离与保乳手术切缘阳性率及标本体积无显著关联。
- 保乳手术切缘阳性的唯一显著预测因素为最终病理导管原位癌(p < 0.001)。
- 切除活检中标签-靶病灶距离≥10 mm与标本体积的关联在校正混杂后不显著(p = 0.12)。
核心结论
- 保乳手术或切除活检中,标签-靶病灶距离与切缘阳性率或手术标本体积之间无显著关联证据。
研究设计与样本
- 回顾性队列分析,纳入2018至2021年间连续进行的射频识别标签定位切除活检与保乳手术,共456个不可触及乳腺病灶(445例患者),采用单因素及多因素分析。
诊断标准与关键数值
- 中位标签-靶病灶距离为4.5 mm。
- 切缘阳性率为15.1%。
- 保乳手术切缘阳性的唯一显著预测因素为最终病理导管原位癌(p < 0.001)。
- 切除活检中标签-靶病灶距离≥10 mm与较大手术标本体积相关仅见于单因素分析(OR:2.961,p = 0.04),校正混杂变量后无显著关联(p = 0.12)。
临床应用与阅片要点
- 作者指出,放射科医生与外科医生沟通后,增大标签-靶病灶距离对手术结局无显著影响。
- 作者认为,对于射频识别标签放置距离较远的情况,是否需额外定位应个体化评估,该数据有助于多学科决策。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Radiofrequency identification (RFID) tag localization (TL) is a method of localizing non-palpable breast lesions. The purpose of our study was to evaluate the association between RFID tag-to-target distance, margin positivity rates, and surgical specimen sizes.
MATERIALS AND METHODS: A retrospective cohort analysis was performed on consecutive TL excisional biopsies and lumpectomies performed between 2018 and 2021. Associations between the longest distance between tag and target, positive margins, and the surgical specimen volume were analyzed using univariate and multivariate analyses.
RESULTS: Four hundred fifty-six non-palpable breast lesions in 445 patients were included, with a median tag-to-target distance of 4.5 mm and a positive margin rate of 15.1%. For lumpectomies, there was no significant association between tag-to-target distance and margin positivity rate, nor surgical specimen size on multivariate analysis. The only significant predictor of positive lumpectomy margins was ductal carcinoma in situ (DCIS) on final pathology (p < 0.001). Significant predictors of increased lumpectomy specimen volume included operating surgeon (p = 0.005) and body mass index (BMI) (p < 0.001). For excisional biopsies, tag-to-target distances ≥ 10 mm were associated with larger surgical specimen size on univariate analysis (OR: 2.961, p = 0.04). However, when confounding variables were adjusted for, there was no significant association between tag-to-target distance ≥ 10 mm and surgical specimen size (p = 0.12). Factors predictive of increased excisional biopsy specimen volume were surgeon (OR: 4.762, p = 0.03), BMI (OR: 1.164, p = 0.001), and age (OR: 1.062, p = 0.007).
CONCLUSION: There was no evidence of a significant association between tag-to-target distance and margin positivity rate or surgical specimen size for lumpectomies or excisional biopsies.
KEY POINTS: Question Currently, there exists little guidance for breast surgeons and radiologists regarding the ideal localization tag-to-target distance prior to breast-conserving surgery. Findings With communication between radiologists and surgeons, increased tag-to-target distance had no significant effect on surgical outcomes. Clinical relevance This data provides guidance regarding the need for additional localization after distant placement of radiofrequency-identification tags. While cases should be assessed individually to determine the need for additional localization, these data better inform multidisciplinary decision-making regarding TL.