文献速递乳腺技术与安全US

基于临床病理变量、常规超声与双模式弹性成像的列线图预测乳腺癌患者肿瘤浸润淋巴细胞水平

Prediction of the Level of Tumor-infiltrating Lymphocytes in Breast Cancer Patients with a Nomogram Based on Clinicopathologic Variables, Conventional Ultrasound and Dual-mode Elastography.
PubMed 文献 · Acad Radiol · 2025-07-29

回顾性纳入2023年1月至11月520例患者共527个浸润性乳腺癌病灶,构建基于临床病理特征、常规超声及双模式弹性成像的列线图预测高肿瘤浸润淋巴细胞(TILs)乳腺癌。高TILs与ER/PR阴性、高组织学分级、LPBC相关形态及后方回声增强、SE应变比降低、SWE壳层2mm平均弹性模量降低相关,列线图训练队列AUC=0.874、内部验证队列AUC=0.913,校准良好。

要点

  • 高TILs乳腺癌在常规超声上呈良性样形态特征,包括LPBC相关形态及后方回声增强。
  • 弹性成像显示高TILs肿瘤整体及周围组织硬度较低,SE应变比降低、SWE壳层2mm平均弹性模量降低。
  • 基于6个变量的列线图可术前预测高TILs乳腺癌,训练队列AUC=0.874、内部验证队列AUC=0.913。

核心结论

  • 高TILs乳腺癌具有特定临床病理特征、常规超声良性样形态特征及弹性成像较低硬度。
  • 整合上述特征的术前列线图有助于预测高TILs肿瘤,可能帮助肿瘤个体化管理。

研究设计与样本

  • 回顾性纳入2023年1月至11月520例患者共527个浸润性乳腺癌病灶(cT1或2,N阴性或阳性,M0)。
  • 所有患者接受常规超声及双模式弹性成像(应变弹性成像SE和剪切波弹性成像SWE),记录整个肿瘤及周围组织的硬度值。
  • 采用逻辑回归构建列线图,并通过受试者工作特征曲线分析和校准曲线分析进行评价。

关键影像表现/征象

  • 常规超声上LPBC相关形态及后方回声增强与高TILs乳腺癌显著相关。
  • SE上FLR降低、SWE上Shell2mm Emean降低与高TILs乳腺癌显著相关。

诊断标准与关键数值

  • 高TILs定义为高肿瘤浸润淋巴细胞水平;527个病灶中83.3%(439/527)为低-中等TILs,88个(16.7%)为高TILs。
  • 列线图由ER/PR阴性、高组织学分级、LPBC相关形态、后方回声增强、SE上FLR降低、SWE上Shell2mm Emean降低共6个变量构建。
  • 列线图预测高TILs肿瘤的训练队列AUC=0.874,内部验证队列AUC=0.913。
  • 校准度:训练队列Hosmer-Lemeshow拟合优度检验p=0.824,内部验证队列p=0.536。

临床应用与阅片要点

  • 术前可综合临床病理特征、常规超声形态及双模式弹性成像硬度值评估高TILs乳腺癌可能性。
  • 阅片时注意LPBC相关形态、后方回声增强等良性样形态特征,并结合SE的FLR及SWE的Shell2mm Emean降低。
  • 列线图可能有助于高TILs肿瘤的个体化管理。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To develop and validate a nomogram based on clinicopathologic features, conventional ultrasound and dual-mode elastography for predicting breast cancers (BCs) with high level of tumor-infiltrating lymphocytes (TILs).

METHODS: A total of 520 patients with 527 invasive breast cancers (cT1or2, N negative or positive, M0) were enrolled retrospectively from January 2023 through November 2023. All patients underwent conventional ultrasound and dual-mode elastography (strain elastography, SE, and shear wave elastography. SWE). Stiffness values of both the entire tumor and the surrounding tissues were recorded. A nomogram was developed by using logistic regression and determined by receiver operating characteristic (ROC) curve analysis and calibration curve analysis.

RESULTS: Among the 527 lesions enrolled into this study,83.3% (439/527) were tumors with low-moderate TILs and 88 (16.7%) with high TILs. ER/PR negative, high histologic grade, LPBC-associated shape and posterior acoustic enhancement on conventional ultrasound, decreased FLR on SE, lower Shell2mm Emean on SWV were significantly associated with high TILs BCs. A nomogram constructed with the above six variables enabled predicting tumors with high TILs in the training cohort (AUC=0.874) and internal validation cohort (AUC=0.913). The nomogram also showed good calibration in the training cohort and internal validation cohorts (Hosmer Lemeshow goodness-of-fit test, p = 0.824 and p = 0.536, respectively).

CONCLUSION: High TILs breast cancers had specific clinicopathological features, benignlike morphological characteristics on conventional ultrasound and lower stiffness on elastography. A preoperative nomogram integrating the above features was useful in predicting high TILs tumors, which might help individualized management of tumors.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Zhu Y, Fei XC, Zhou QF, et al. Prediction of the Level of Tumor-infiltrating Lymphocytes in Breast Cancer Patients with a Nomogram Based on Clinicopathologic Variables, Conventional Ultrasound and Dual-mode Elastography. Acad Radiol. 2025. PMID: 40738774. doi:10.1016/j.acra.2025.07.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。