文献速递妇产影像MR

T2加权与对比增强T1加权MultiVane序列在子宫内膜癌术前评估中的有效性

Effectiveness of T2-weighted and contrast-enhanced T1-weighted multivane sequences in the preoperative evaluation of uterine endometrial cancer.
PubMed 文献 · Abdom Radiol (NY) · 2025-07-17

本研究纳入42例经组织病理学确诊的子宫内膜癌患者,术前MRI采用TSE与MV序列采集矢状位T2WI和CE-T1WI,比较运动伪影、SNR、CR及肌层浸润诊断效能;MV序列运动伪影显著改善(p<0.01),SNR和CR无显著差异(p>0.05),肌层浸润诊断的敏感度、特异度、准确率和AUC在MV序列略高但无统计学差异(p>0.05)。

要点

  • MV序列较TSE序列显著改善运动伪影(p<0.01)。
  • MV与TSE序列的SNR和CR无显著差异(p>0.05)。
  • MV序列诊断肌层浸润的敏感度、特异度、准确率及AUC较TSE略高,但无统计学差异(p>0.05)。

核心结论

  • MV序列在不降低子宫内膜癌和子宫肌层SNR及CR的前提下改善女性盆腔运动伪影,但未显著提高肌层浸润诊断效能,可能归因于成像平面受限和样本量小。

研究设计与样本

  • 本研究纳入42例经组织病理学确诊的子宫内膜癌患者,术前行MRI包括矢状位T2WI和CE-T1WI,分别采用TSE和MV序列采集且采集时间大致匹配;两名经验丰富的放射科医生独立评估所有矢状位图像。

关键影像表现/征象

  • MV序列较TSE序列显著改善运动伪影(p<0.01)。
  • TSE与MV序列的SNR和CR无显著差异(p>0.05)。

诊断标准与关键数值

  • MV序列诊断肌层浸润的敏感度、特异度、准确率和AUC较TSE序列略增高,但差异无统计学意义(p>0.05)。

局限性

  • MV序列未显著改善子宫内膜癌肌层浸润的诊断效能,可能归因于成像平面受限和样本量小。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The purpose of this study was to evaluate the clinical effectiveness of MultiVane (MV) sequence, which is a motion correction technique using rotating blades, for patients with uterine endometrial cancer.

MATERIALS AND METHODS: This study enrolled 42 patients with histopathologically confirmed uterine endometrial cancer, who underwent preoperative MRI including sagittal T2-weighted images (T2WI) and contrast-enhanced T1-weighted images (CE-T1WI) acquired using both turbo spin-echo (TSE) and MV sequences with approximately matched acquisition times. Two experienced radiologists independently evaluated all sagittal images. First, the readers assessed the degree of motion artifacts and measured the signal intensity of the tumor and myometrium to calculate the signal-to-noise ratio (SNR) and tumor-to-myometrium contrast ratio (CR). Second, the readers assessed the depth of myometrial invasion on sagittal T2WI and CE-T1WI acquired using TSE and MV sequences. Image quality and diagnostic performance for assessing myometrial invasion were compared between TSE and MV sequences.

RESULTS: Motion artifacts were significantly improved on MV sequence than on TSE sequence (p < 0.01). The SNR and CR were not significantly different between TSE and MV sequences (p > 0.05). Sensitivities, specificities, accuracies, and area under the curve for the diagnosis of myometrial invasion were slightly increased on MV sequence than on TSE sequence, but these differences were not statistically significant (p > 0.05).

CONCLUSION: MV sequence contributes to the improvement of motion artifacts in the female pelvis without degrading SNR and CR of endometrial cancer and myometrium compared to TSE sequence. MV sequence did not significantly improve the diagnostic performance for assessing myometrial invasion in endometrial cancer, possibly due to the limited imaging plane and small sample size.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Ando T, Kato H, Maeda T, et al. Effectiveness of T2-weighted and contrast-enhanced T1-weighted multivane sequences in the preoperative evaluation of uterine endometrial cancer. Abdom Radiol (NY). 2025. PMID: 40673939. doi:10.1007/s00261-025-05107-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。