深度学习加速前列腺MRI:提升速度、准确性与可持续性
本研究前瞻性纳入51例接受深度学习增强采集的前列腺MRI患者,对比四倍并行采集技术(P4)与两倍并行采集技术(P2)的T2加权序列图像质量与扫描效率。P4较P2显著提高CNR和SNR(p<.001),图像质量与诊断精度评分更优(p<.001),并将T2w扫描时间从11:48 min缩短至5:48 min,降低50.8%(p<.001)。
要点
- P4较P2显著提高前列腺MRI的CNR和SNR(p<.001),图像质量与诊断精度评分更优(p<.001)。
- P4将T2w扫描时间从11:48 min缩短至5:48 min,降低50.8%(p<.001)。
- 放射组学分析显示P4较P2显著改变结构及纹理特征(p<.05)。
核心结论
- P4成像提升诊断质量并缩短扫描时间,改善工作流程效率,可能有助于更以患者为中心和可持续的放射学实践。
研究设计与样本
- 前瞻性研究,纳入2024年1月至2024年7月接受深度学习增强采集的前列腺MRI患者51例(平均年龄69.4岁±10.5岁),所有成像平面T2加权序列均同时采用P2和P4采集,由三名独立阅片者评估图像质量、SNR和CNR,并进行放射组学分析。
诊断标准与关键数值
- P4较P2具有更高的CNR和SNR值(p<.001)。
- P4在所有评估类别中图像质量和诊断精度评分均优于P2(p<.001)。
- 放射组学分析显示P4较P2显著改变结构和纹理区分(p<.05)。
- P4方案将T2w扫描时间从11:48 min缩短至5:48 min,降低50.8%(p<.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: This study aims to evaluate the effectiveness of a deep learning (DL)-enhanced four-fold parallel acquisition technique (P4) in improving prostate MR image quality while optimizing scan efficiency compared to the traditional two-fold parallel acquisition technique (P2).
MATERIALS AND METHODS: Patients undergoing prostate MRI with DL-enhanced acquisitions were analyzed from January 2024 to July 2024. The participants prospectively received T2-weighted sequences in all imaging planes using both P2 and P4. Three independent readers assessed image quality, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR). Significant differences in contrast and gray-level properties between P2 and P4 were identified through radiomics analysis (p <.05).
RESULTS: A total of 51 participants (mean age 69.4 years ± 10.5 years) underwent P2 and P4 imaging. P4 demonstrated higher CNR and SNR values compared to P2 (p <.001). P4 was consistently rated superior to P2, demonstrating enhanced image quality and greater diagnostic precision across all evaluated categories (p <.001). Furthermore, radiomics analysis confirmed that P4 significantly altered structural and textural differentiation in comparison to P2. The P4 protocol reduced T2w scan times by 50.8%, from 11:48 min to 5:48 min (p <.001).
CONCLUSION: In conclusion, P4 imaging enhances diagnostic quality and reduces scan times, improving workflow efficiency, and potentially contributing to a more patient-centered and sustainable radiology practice.
引用
- Reschke P, Koch V, Gruenewald LD, et al. Deep Learning-Accelerated Prostate MRI: Improving Speed, Accuracy, and Sustainability. Acad Radiol. 2025. PMID: 40664559. doi:10.1016/j.acra.2025.06.022
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。