文献速递腹部技术与安全CT

分次团注双能CT与标准多期CT评估胆道恶性肿瘤血管侵犯的比较:一项随机研究

Comparison of split bolus dual energy CT and standard multiphase CT in assessing vascular invasion in patients with biliary malignancies: a randomized study.
PubMed 文献 · Abdom Radiol (NY) · 2025-07-11

该前瞻性随机研究纳入88例胆道恶性肿瘤患者,比较分次团注双能CT(SBP)与标准多期CT(MPP)的图像质量、血管侵犯定义及辐射剂量。结果显示SBP图像质量不劣于MPP,对肝动脉侵犯的读者间一致性显著更高,且辐射剂量降低37%。

要点

  • 分次团注双能CT对肝动脉侵犯的读者间一致性显著高于标准多期CT动脉期(p<0.001)。
  • 分次团注双能CT辐射剂量较标准多期CT降低37%(p<0.001)。
  • 分次团注双能CT图像质量不劣于标准多期CT,静脉和肿瘤定量参数两者相当。

核心结论

  • 分次团注双能CT图像质量不劣于标准多期CT,对动脉侵犯的读者间一致性显著更好,且辐射剂量显著更低。

研究设计与样本

  • 前瞻性随机研究,2020年12月至2022年11月纳入88例胆道恶性肿瘤患者,随机分为两组,使用快速切换双能CT扫描仪。

关键影像表现/征象

  • 第1组动脉期动脉的平均衰减、CNR和SNR显著高于第2组分次团注期,而第1组静脉期则显著低于第2组分次团注期(p<0.001)。
  • 第1组静脉期与第2组分次团注期的静脉和肿瘤定量参数相当。
  • 两种方案的图像质量读者间一致性为良好至强(k=0.45至0.75)。

诊断标准与关键数值

  • 采用5点Likert量表独立评估图像质量和血管侵犯。
  • 肝动脉侵犯的读者间一致性:分次团注双能CT显著高于标准多期CT动脉期(p<0.001)。
  • 辐射剂量:分次团注双能CT较标准多期CT降低37%(p<0.001)。

临床应用与阅片要点

  • 分次团注双能CT可在同一期相清晰显示动脉和肿瘤,有助于自信评估血管侵犯。
  • 胆道恶性肿瘤在静脉期显示更佳,但动脉显示不清,使动脉侵犯评估困难;分次团注双能CT克服了这一点。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare the image quality, definition of vascular invasion and radiation dose of split bolus dual energy CT (DECT) with standard multiphase CT in biliary malignancies.

MATERIALS AND METHODS: This prospective study performed from December 2020 to November 2022 included 88 patients of biliary malignancies randomized into two groups and scanned on rapid-switching dual energy CT scanner. Group 1 (n = 43, mean age: 54.6 years, 12 males) underwent the standard multiphase protocol (MPP; arterial, venous phases), while group 2 (n = 45, mean age: 52.6 years, 20 males) underwent split bolus dual-energy protocol (SBP; split-bolus phase). The mean attenuation, contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of tumor, liver and hepatic vessels were measured and compared between the two groups along with dose-length product. Two readers independently assessed image quality and vascular invasion (5-point Likert scale) in each phase and inter-reader agreement was compared within groups. Mann Whitney U-test and kappa statistics were used for comparison.

RESULTS: The mean attenuation, CNR and SNR of arteries were significantly higher in the arterial phase of group 1 and significantly lower in the venous phase of group 1 than the SBP of group 2 (p < 0.001). The quantitative parameters of veins and tumor between venous phase (group 1) and SBP (group 2) were comparable. Good-to-strong inter-reader agreement (k = 0.45 to 0.75) for image quality for both protocols was observed. For hepatic arterial invasion, the SBP had significantly higher inter-reader agreement compared to the arterial phase of MPP (p < 0.001). The SBP had a 37% lower radiation dose than the MPP (p < 0.001).

CONCLUSION: The image quality of SBP was non-inferior to the standard MPP for biliary malignancies. However, SBP showed significantly better inter-observer agreement for arterial invasion indicating better assessment of vascular involvement with significantly lower radiation dose.

CLINICAL RELEVANCE: Biliary malignancies are better defined in the venous phase in which arteries are indistinct, making arterial invasion assessment tough. SBP overcomes this by clearly depicting arteries and tumor in the same phase for confident assessment.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Nikhileswar K, Sharma S, Srivastava DN, et al. Comparison of split bolus dual energy CT and standard multiphase CT in assessing vascular invasion in patients with biliary malignancies: a randomized study. Abdom Radiol (NY). 2025. PMID: 40643653. doi:10.1007/s00261-025-05111-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。