文献速递胸部腹部泌尿生殖CT

急诊科不明原因疑似感染:非重症患者胸腹盆CT的诊断价值

Suspected infection of unclear origin at the emergency department: diagnostic yield of thoraco-abdominal-pelvic CT in non-severe patients.
PubMed 文献 · Br J Radiol · 2025-01-01

该回顾性研究纳入517例急诊非重症不明原因疑似感染患者的胸腹盆CT,55%发现感染灶(主要为肺部46%、胆道消化25%、泌尿生殖23%),20%发现显著非感染性病变(肿瘤12%、血栓7%)。CT与最终诊断敏感度73%、特异度88%、阳性预测值94%、阴性预测值57%,Kappa=0.53;C反应蛋白<128 mg/L与正常CT相关,但无模型能可靠预测正常扫描。

要点

  • 胸腹盆CT在55%的非重症不明原因疑似感染患者中检出感染灶,肺部最常见(46%)。
  • 20%检出显著非感染性病变,包括肿瘤12%和血栓7%,提示CT可发现感染模仿病变。
  • C反应蛋白<128 mg/L与正常胸腹盆CT相关,但无模型能可靠预测正常扫描。

核心结论

  • 胸腹盆CT在超过三分之二的病例中检出相关发现,强化了其在诊断感染性及模仿性疾病中的作用;无特定标准能安全排除胸腹盆CT,使其成为管理不明原因疑似感染患者的有价值工具。

研究设计与样本

  • 回顾性研究,纳入517例成人非重症不明原因疑似感染患者的胸腹盆CT检查,按是否存在感染灶或显著发现(如肿瘤或血栓)进行分类,行描述性分析、CT结果与最终诊断的对应性评估及统计建模以识别正常胸腹盆CT的预测因素。

关键影像表现/征象

  • 55%的胸腹盆CT检出感染灶,主要为肺部(46%)、胆道消化(25%)和泌尿生殖(23%)。
  • 20%检出显著非感染性发现,包括血栓(7%)和肿瘤(12%)。

诊断标准与关键数值

  • 胸腹盆CT诊断感染灶的敏感度73%、特异度88%、阳性预测值94%、阴性预测值57%。
  • 胸腹盆CT结果与最终诊断的一致性为中等(Kappa=0.53)。
  • C反应蛋白<128 mg/L与正常胸腹盆CT相关,但无模型能可靠预测正常扫描。

临床应用与阅片要点

  • 胸腹盆CT在超过三分之二的病例中检出相关发现,可同时诊断感染性及模仿性疾病。
  • 无特定标准能安全排除胸腹盆CT,原文据此未给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess the diagnostic yield of thoraco-abdominal-pelvic computed tomography (TAP-CT) in suspected infection of unclear origin in the emergency department (ED) and identify predictive factors for normal TAP-CT to optimize its use.

METHODS: We retrospectively categorized 517 TAP-CT studies of adult patients with non-severe infection of unclear origin based on the presence of an infectious focus or significant findings, such as neoplasia or thrombosis. Descriptive analysis, correspondence assessment between CT results and final diagnosis, and statistical modelling were performed to identify predictors of normal TAP-CT.

RESULTS: An infectious focus was identified in 55% TAP-CT scans, mainly pulmonary (46%), bilio-digestive (25%), and genitourinary (23%). Significant non-infectious findings were detected in 20%, including thrombosis (7%) and neoplasia (12%). TAP-CT showed a sensitivity of 73%, specificity of 88%, positive predictive value of 94%, and negative predictive value of 57%, with moderate agreement (Kappa = 0.53) between TAP-CT findings and final diagnosis. Overall, 67% of patients had an identifiable cause for infection-like symptoms. Although C-reactive protein <128 mg/L was associated with normal TAP-CT, no model reliably predicted a normal scan.

CONCLUSIONS: TAP-CT identified a relevant finding in over two-thirds of cases, reinforcing its role in diagnosing both infectious and mimicking conditions. No specific criteria could safely exclude TAP-CT, making it a valuable tool for managing patients with suspected infections of unclear origin.

ADVANCES IN KNOWLEDGE: This study is the first to assess TAP-CT's value in suspected non-severe infections of unclear origin in the ED, highlighting its role in detecting infectious and non-infectious conditions and optimizing diagnostic strategies.

来源:Br J Radiol,查看原文。版权归原作者所有。