文献速递腹部CT

单纯形算法确定阑尾炎显示的最佳keV与窗设置

A Simplex algorithm approach to determine the optimal keV and window setting for appendicitis visualization.
PubMed 文献 · Eur J Radiol · 2025-07-17

本研究回顾性纳入34例经双能CT诊断的阑尾炎患者,用四维单纯形优化算法由6名放射科医生对14种keV(40–70)和不同窗参数(中心5–290 HU、宽度205–570 HU)共2856次判读进行评分,确定40 keV下窗中心57–79 HU、窗宽357–418 HU时阑尾壁强化显示最佳(平均显示度评分4.4±0.0)。

要点

  • 40 keV下阑尾壁强化显示度最高的窗设置为窗中心57–79 HU、窗宽357–418 HU。
  • 该范围内背景最佳处为窗中心57 HU、窗宽418 HU。
  • 算法优化双能增强CT的keV与窗设置可能改善阑尾炎黏膜强化等急性炎症的显示。

核心结论

  • 双能增强CT的keV与窗设置经算法优化后,可能使阑尾炎黏膜强化等急性炎症病理过程获得更好显示。

研究设计与样本

  • 回顾性识别34例经双能CT诊断的阑尾炎患者。
  • 采用迭代四维单纯形优化算法确定最佳keV与窗设置。
  • 评估14种keV(40–70范围)和窗参数(中心5–290 HU、宽度205–570 HU),由6名放射科医生判读,共2856次判读。

关键影像表现/征象

  • 40 keV下窗中心57–79 HU、窗宽357–418 HU时平均显示度评分最高(4.4±0.0)。
  • 该范围内背景最佳处为窗中心57 HU、窗宽418 HU。

诊断标准与关键数值

  • 阑尾壁强化显示度采用5分制评分,整体图像质量采用3分制评分。
  • 在初始评估4组参数后,经10次参数迭代达到最佳窗设置的收敛。

临床应用与阅片要点

  • 阅读双能CT阑尾炎图像时,40 keV下可参考窗中心57–79 HU、窗宽357–418 HU观察阑尾壁强化。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Contrast-enhanced dual energy CT, with low-mono-energetic CT scanning (conventional 70 keV and low-mono energetic 40 keV) can improve visualization of acute inflammatory processes, but the high iodine attenuation often requires adjustment of window display settings to optimize interpretation. Here, we aim to determine optimal keV and window settings for the visualization of acute appendicitis from images derived from low-mono-energetic-CT.

METHODS: 34 patients diagnosed with appendicitis, using dual energy CT, were retrospectively identified. An iterative four-dimensional Simplex optimization algorithm was used to determine optimal keV and windowing for assessment. 14 different keVs (40-70 range) and window parameters (center 5-290 HU; width 205-570 HU) were evaluated by 6 radiologists. Each reader individually graded the conspicuity of appendix wall enhancement using a 5-point scale and the overall image quality on a 3-point scale. Three-dimensional contour maps of the relationship between window settings and overall averages of reader grade at 40 keV were constructed.

RESULTS: Convergence to optimal windowing was achieved over ten parameter iterations following the initial evaluation of 4 different parameter sets. This amounted to a total of 2,856 reads (14 keVs and window settings x 6 readers x 34 cases). The highest average conspicuity grade (4.4 ± 0.0) was achieved at 40 keV with windows of 57-79 HU center and 357-418 HU width, with best background in this range at window 57 HU and center 418 HU.

CONCLUSIONS: Algorithmic optimization of dual energy contrast-enhanced CT scans may allow better visualization of acute inflammatory pathological processes such as mucosal enhancement in appendicitis by tailoring keV levels and window settings.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Adam N, Nahum GS, Marron D, et al. A Simplex algorithm approach to determine the optimal keV and window setting for appendicitis visualization. Eur J Radiol. 2025. PMID: 40682979. doi:10.1016/j.ejrad.2025.112282

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。