文献速递腹部CT

基于机器学习的影像组学在三期增强CT中鉴别肝脏局灶性病变良恶性

Differentiation of malignant from benign focal liver lesions in triphase-enhanced CT using machine-learning-based radiomics.
PubMed 文献 · Br J Radiol · 2025-01-01

回顾性纳入322个经组织病理学证实的肝脏局灶性病变,提取动脉期、门静脉期、延迟期及期相间斜率的影像组学特征构建模型。测试集中影像组学标签鉴别恶性病变的AUC为0.896(0.850-0.973),低于高年资放射科医师的0.935(0.873-0.996)(P=0.463),高于两名低年资医师的0.812(0.713-0.910)(P=0.228)和0.747(0.667-0.827)(P=0.016)。

要点

  • 测试集中影像组学标签鉴别恶性肝脏局灶性病变的AUC为0.896(0.850-0.973)。
  • 高年资放射科医师AUC为0.935(0.873-0.996),影像组学标签与之差异无统计学意义(P=0.463)。
  • 影像组学标签AUC高于一名低年资医师的0.747(0.667-0.827)(P=0.016)。

核心结论

  • 基于三期增强CT的影像组学模型在鉴别肝脏局灶性病变良恶性方面表现良好,可能成为筛查阳性病例并避免假阴性的潜在工具。

研究设计与样本

  • 回顾性纳入接受三期增强CT检查且有组织病理学结果的肝脏局灶性病变患者,共322个病变,训练集160个(恶性122个,76.3%)、验证集83个(恶性63个,75.9%)、测试集79个(恶性63个,79.7%)。
  • 提取动脉期、门静脉期、延迟期以及动脉期至门静脉期斜率、门静脉期至延迟期斜率的影像组学特征。
  • 采用Boruta算法和随机森林算法筛选最佳鉴别良恶性的特征并组合构建影像组学标签。
  • 三名放射科医师独立进行肝脏影像报告和数据系统分类评分。

诊断标准与关键数值

  • 测试集中影像组学标签鉴别恶性肝脏局灶性病变的AUC为0.896(0.850-0.973)。
  • 测试集中高年资放射科医师鉴别恶性病变的AUC为0.935(0.873-0.996),影像组学标签与之比较P=0.463。
  • 测试集中两名低年资放射科医师鉴别恶性病变的AUC分别为0.812(0.713-0.910)(与影像组学标签比较P=0.228)和0.747(0.667-0.827)(P=0.016)。
  • 三名观察者分别将235个、169个和220个病变分类为恶性。

临床应用与阅片要点

  • 作者认为基于三期增强CT的影像组学模型可能作为筛查阳性病例并避免假阴性的潜在工具。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Triphasic enhanced CT provides more information about blood supply. The aim was to establish a radiomics model of triphasic-enhanced CT to differentiate malignant from benign focal liver lesions (FLLs).

METHODS: Patients with FLLs who underwent triphasic enhanced CT with histopathological results were retrospectively included. We extracted the radiomic features of each lesion in arterial phase (AP), portal vein phase (PVP), delayed phase (DP), slope of AP to PVP, and slope of PVP to DP. The features that best discriminated malignant from benign FLLs were selected using the Boruta algorithm and random forest algorithm and combined to create a radiomic signature. Three radiologists independently graded the Liver Imaging Reporting and Data System category.

RESULTS: Of the 322 FLLs, the training, validation and test cohorts consisted of 160 (122 malignant, 76.3%), 83 (63 malignant, 75.9%), and 79 (63 malignant, 79.7%) lesions. The three observers classified 235, 169, and 220 as malignant, respectively. In the test cohort, the area under the curve of the radiomic signature in identifying malignant FLLs was 0.896 (0.850-0.973), lower than 0.935 (0.873-0.996) (P = .463) of the senior radiologist, but higher than 0.812 (0.713-0.910) (P = .228) and 0.747 (0.667-0.827) (P = .016) of the two less-experienced radiologists.

CONCLUSIONS: The radiomics-based model for triphasic enhanced CT images performed well in differentiating malignant from benign FLLs and may be a potential tool to screen for positive cases and avoid false negatives.

ADVANCES IN KNOWLEDGE: The radiomics-based model for triphasic enhanced CT achieved high performance in differentiating malignant from benign FLLs and may help to screen for positive cases and avoid false negatives.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Wang L, Xu Z, Zhang L, et al. Differentiation of malignant from benign focal liver lesions in triphase-enhanced CT using machine-learning-based radiomics. Br J Radiol. 2025. PMID: 40581616. doi:10.1093/bjr/tqaf138

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。