文献速递腹部外周血管技术与安全MR

四维血流磁共振成像测量的内脏血流动力学参数可诊断严重门静脉高压

Splanchnic hemodynamic parameters measured with 4D flow MRI can diagnose severe portal hypertension.
PubMed 文献 · Eur Radiol · 2025-07-15

单中心前瞻性研究纳入50例慢性肝病患者,在注射钆塞酸后10分钟行1.5T四维血流磁共振成像,测量内脏血管血流动力学参数。腹腔干峰值流速联合肠系膜上静脉流量的逻辑回归模型诊断严重门静脉高压(肝静脉压力梯度≥12 mmHg)的AUC为0.95,敏感度100%、特异度89%;肝动脉和脾动脉面积等参数对预测肝失代偿有良好诊断效能。

要点

  • 腹腔干峰值流速诊断严重门静脉高压AUC为0.90,肠系膜上静脉面积AUC为0.88。
  • 腹腔干峰值流速联合肠系膜上静脉流量的模型诊断严重门静脉高压AUC为0.95,敏感度100%、特异度89%。
  • 肝动脉面积和脾动脉面积预测肝失代偿AUC均为0.74,腹腔干流量AUC为0.70,肠系膜上静脉流量AUC为0.72。

核心结论

  • 四维血流磁共振成像测量的内脏血流动力学参数对诊断严重门静脉高压有极好效能,对预测肝失代偿有良好效能。

研究设计与样本

  • 单中心前瞻性研究(2018—2022年),纳入50例接受经颈静脉肝活检及楔压法肝静脉压力梯度测量并行腹部四维血流磁共振成像的患者,MRI与肝静脉压力梯度测量间隔28±18天(范围1—78天)。

关键影像表现/征象

  • 四维血流磁共振成像于1.5T采集,注射钆塞酸后10分钟进行,采用原型序列,冠状斜位,编码速度60 cm/s。
  • 多名观察者手动分割门静脉、肠系膜上静脉、脾静脉、肝中静脉、腹腔干上方主动脉、腹腔干、肝动脉和脾动脉。
  • 比较有无严重门静脉高压及有无未来肝失代偿患者的时间平均血管横截面积、穿透平面时间平均流速和流量及峰值流速。

诊断标准与关键数值

  • 严重门静脉高压定义为肝静脉压力梯度≥12 mmHg。
  • 腹腔干峰值流速诊断严重门静脉高压AUC(95%CI)为0.90(0.80—0.99),肠系膜上静脉面积AUC(95%CI)为0.88(0.77—0.99)。
  • 腹腔干峰值流速联合肠系膜上静脉流量的逻辑回归模型诊断严重门静脉高压AUC(95%CI)为0.95(0.88—1.00),敏感度100%,特异度89%。
  • 预测肝失代偿:肝动脉面积AUC(95%CI)为0.74(0.57—0.92),脾动脉面积AUC(95%CI)为0.74(0.52—0.96),腹腔干流量AUC(95%CI)为0.70(0.51—0.89),肠系膜上静脉流量AUC(95%CI)为0.72(0.55—0.89)。

临床应用与阅片要点

  • 四维血流磁共振成像可能可整合入肝硬化患者的临床磁共振成像方案中。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess the diagnostic performance of splanchnic hemodynamic parameters measured with 4D flow MRI for diagnosis of severe portal hypertension (PH; hepatic venous pressure gradient (HVPG) ≥ 12 mmHg), and prediction of liver decompensation in patients with chronic liver disease.

MATERIALS AND METHODS: Our single-center prospective study (2018-2022) enrolled patients undergoing transjugular liver biopsy with wedge HVPG measurement for abdominal 4D flow MRI (MRI-HVPG interval = 28 ± 18 (1-78) days). 4D flow MRI was acquired at 1.5 T, 10 min. after injection of gadoxetic acid, with a prototype sequence in coronal-oblique orientation (VENC = 60 cm/s). Multiple observers manually segmented the portal, superior mesenteric, splenic and middle hepatic veins, supraceliac aorta, celiac trunk, hepatic and splenic arteries. Time-averaged vessel cross-section area, through-plane time-averaged velocity and flow, and peak velocity were compared between patients with/without severe PH, and with/without future liver decompensation by Mann-Whitney U test and ROC analysis.

RESULTS: 50 patients (M/F: 26/24, age = 52 ± 15 years) were included, of which 47 had clinical follow-up 1084 ± 618 days after MRI. Twenty-three of 50 (46%) patients had PH, 8/50 (16%) had severe PH, and 12/47 (26%) had decompensation. Celiac trunk peak velocity [AUC (95% CI) = 0.90 (0.80-0.99)] and superior mesenteric vein area [AUC (95% CI) = 0.88 (0.77-0.99)] identified severe PH with the highest diagnostic performance. A logistic regression model combining celiac trunk peak velocity and superior mesenteric vein flow identified severe PH with AUC (95% CI) = 0.95 (0.88-1.00), sensitivity = 100%, specificity = 89%. Hepatic [AUC (95% CI) = 0.74 (0.57-0.92)] and splenic artery [AUC (95% CI) = 0.74 (0.52-0.96)] area, celiac trunk [AUC (95% CI) = 0.70 (0.51-0.89)] and superior mesenteric vein [AUC (95% CI) = 0.72 (0.55-0.89)] flow predicted liver decompensation with good diagnostic performance.

CONCLUSION: Splanchnic 4D flow MRI measurements have excellent performance for diagnosing severe PH and good performance for predicting liver decompensation.

KEY POINTS: Question Noninvasive detection of severe portal hypertension (hepatic venous pressure gradient ≥ 12 mmHg) is important to prevent bleeding, decompensation, and death in patients with chronic liver disease. Findings Splanchnic hemodynamic measurements by 4D flow MRI can identify patients with severe portal hypertension and predict liver decompensation with excellent/good diagnostic performance. Clinical relevance 4D flow MRI can potentially be integrated into the clinical MRI protocols of patients with liver cirrhosis.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Bane O, Geahchan A, Stocker D, et al. Splanchnic hemodynamic parameters measured with 4D flow MRI can diagnose severe portal hypertension. Eur Radiol. 2025. PMID: 40664866. doi:10.1007/s00330-025-11799-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。