文献速递介入腹部CTDSA

单室经导管CT肝血管造影用于微波肝消融的可行性与安全性研究

Single-room transcatheter CT hepatic angiography for microwave liver ablation: a feasibility and safety study.
PubMed 文献 · Br J Radiol · 2025-01-01

本研究前瞻性评估了使用移动C臂在单室内实施经导管CT肝血管造影(CTHA)辅助微波肝消融的可行性与安全性。20例患者共21次CTHA操作,可行性与技术成功率均为100%,无CTHA相关并发症。中位导管置入时间10分16秒,对比剂剂量174 mL(7次采集),剂量面积乘积18.86 Gy·cm²,97%肿瘤(32/33)可见且均被消融区完全覆盖。

要点

  • 单室CTHA使用移动C臂辅助肝消融可行且安全,无CTHA相关并发症。
  • 97%肿瘤(32/33)可见,且所有可见肿瘤均被消融区完全覆盖。
  • 中位对比剂剂量174 mL(7次采集),剂量面积乘积18.86 Gy·cm²。

核心结论

  • 使用移动C臂的单室CTHA用于肝肿瘤消融可行且安全,能增强肿瘤和消融区可见性,对比剂用量低,允许多次采集和实时切缘评估,且无需昂贵基础设施即可实施。

研究设计与样本

  • 前瞻性服务评估,在放射风险评估和专家中心培训后开展;共纳入20例患者(14名男性,中位年龄66岁),行21次CTHA操作(2024年4月至9月);使用移动透视C臂,技术成功定义为获取CTHA图像。

诊断标准与关键数值

  • 可行性定义为能将CTHA整合入四小时消融 session 的能力,可行性与技术成功率均为100%;97%肿瘤(32/33)可见;所有可见肿瘤均被消融区完全覆盖(使用图像融合软件评估)。

临床应用与阅片要点

  • 作者认为该技术可在具备导管操作经验的中心实施,无需昂贵基础设施,并可能改善肝消融结局和扩大先进介入肿瘤学技术的可及性;本研究为前瞻性服务评估,非指南推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Transcatheter CT hepatic angiography (CTHA) enhances liver tumour ablation by enabling multiple direct intra-arterial contrast injections during a single procedure. We report the implementation of a single-room CTHA workflow using a mobile fluoroscopic C-arm, focusing on feasibility and safety.

METHODS: A prospective service evaluation was conducted following a radiation risk assessment and training at an expert centre. Feasibility-defined as the ability to integrate CTHA into a four-hour ablation session-was assessed alongside technical success, which was defined as acquisition of CTHA images. All CTHA-related adverse events were recorded and graded using the Common Terminology Criteria for Adverse Events (CTCAE). Radiation dose, contrast volume, and tumour visualization were also documented.

RESULTS: Twenty patients (14 men, median age 66 years) underwent 21 CTHA procedures (April-September 2024). Feasibility and technical success were 100%, without any instance of CTHA-related complications. Median catheterization time was 10 min16 s, contrast dose was 174 mL (7 acquisitions), and radiation dose-area product was 18.86 Gy·cm2. Ninety-seven percent of tumours (32/33) were visible. All these tumours were completely covered by an ablation zone using image fusion software.

CONCLUSIONS: Single-room CTHA using a mobile C-arm is feasible and safe for liver tumour ablation. This technique enhances tumour and ablation zone visibility whilst requiring low contrast volumes, enabling multiple acquisitions and real-time margin assessment. Our technique can be readily implemented without expensive infrastructure, holding significant promise in improving liver ablation outcomes and broadening access to advanced interventional oncology techniques.

ADVANCES IN KNOWLEDGE: Single-room CTHA can be readily implemented in centres with catheterization experience, without expensive infrastructure. The method holds significant promise in improving liver ablation outcomes and broadening access to state-of-the-art interventional oncology techniques globally.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Johnston EW, Basso J, Farooq S, et al. Single-room transcatheter CT hepatic angiography for microwave liver ablation: a feasibility and safety study. Br J Radiol. 2025. PMID: 40580446. doi:10.1093/bjr/tqaf117

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。