文献速递腹部技术与安全USMR

超声肝脏脂肪定量以MRI脂肪分数为参考标准评估肝脂肪变性的性能

Performance of Ultrasound Liver Fat Quantification for the Assessment of Hepatic Steatosis Using MRI Fat Fraction as a Reference Standard.
PubMed 文献 · Ultrasound Med Biol · 2025-07-05

这项前瞻性研究纳入152例成人患者,同日进行超声肝脏脂肪定量(LFQ)与3T-MRI mDixonQuant序列脂肪分数测定。LFQ诊断各级肝脂肪变性的AUC为0.919–0.974,操作者内和操作者间ICC分别为0.88和0.85,性能显著优于肝肾指数。

要点

  • LFQ诊断≥1级、≥2级、3级脂肪变性的AUC分别为0.919、0.970、0.974。
  • LFQ cutoff >0.60诊断≥1级脂肪变性敏感度80.3%、特异度92.4%。
  • LFQ cutoff >0.69诊断3级脂肪变性敏感度100%、特异度93.7%。

核心结论

  • 基于超声的肝脏脂肪定量对肝脂肪变性诊断性能优异且重复性高,所有脂肪变性级别下LFQ性能均显著高于肝肾指数。

研究设计与样本

  • 前瞻性研究,纳入152例成人患者(77例男性,中位年龄64.0岁),同日行超声LFQ与3T-MRI mDixonQuant序列脂肪分数测定作为参考标准。

关键影像表现/征象

  • 超声LFQ测量肝实质衰减,基于两名操作者各10次测量的中位数,中位LFQ为0.58 dB/cm/MHz。
  • LFQ检查成功率100%,操作者内和操作者间ICC分别为0.88和0.85。

诊断标准与关键数值

  • MRI参考标准下,39例(25.7%)为1级、11例(7.2%)为2级、10例(6.6%)为3级脂肪变性。
  • LFQ诊断≥1级脂肪变性:AUC 0.919,cutoff >0.60,敏感度80.3%,特异度92.4%。
  • LFQ诊断≥2级脂肪变性:AUC 0.970,cutoff >0.64,敏感度95.2%,特异度85.5%。
  • LFQ诊断3级脂肪变性:AUC 0.974,cutoff >0.69,敏感度100%,特异度93.7%。

临床应用与阅片要点

  • LFQ检查成功率高且重复性好,可作为超声评估肝脂肪变性的定量指标。
  • LFQ在各级脂肪变性中的诊断性能均显著高于肝肾指数。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the performance and reproducibility of ultrasound-based liver fat quantification (LFQ) for the assessment of hepatic steatosis.

METHODS: This prospective study included adult patients who underwent quantification of hepatic steatosis with ultrasound and magnetic resonance imaging (MRI) on the same day. Ultrasounds were acquired with LFQ to measure attenuation of the liver parenchyma, hepatorenal index and 2-D shear-wave elastography, based on the median of 10 measurements taken by two operators. The reference standard was based on fat fraction quantification obtained using the mDixonQuant sequence on a 3T-MRI. Areas under the receiver operator curve and optimal cutoffs with the Youden index were calculated. Inter- and intra-observer reliability was assessed using the intra-class correlation coefficient.

RESULTS: A total of 152 patients (77 males, median age 64.0 years) were enrolled. On MRI, 39 (25.7%), 11 (7.2%) and 10 (6.6%) patients had grade 1, 2 and 3 steatosis, respectively. The median LFQ was 0.58 dB/cm/MHz, with a 100% success rate. Intra- and inter-operator reliability was good, with an intra-class correlation coefficient of 0.88 and 0.85, respectively. The areas under the receiver operator curve of LFQ were 0.919 (cutoff >0.60, sensitivity 80.3%, specificity 92.4%) for grade ≥1 steatosis, 0.970 (cutoff >0.64, sensitivity 95.2%, specificity 85.5%) for grade ≥2 steatosis and 0.974 (cutoff >0.69, sensitivity 100%, specificity 93.7%) for grade 3 steatosis. For all steatosis grades, LFQ performance was significantly higher than the hepatorenal index.

CONCLUSION: Ultrasound-based LFQ provides excellent performance for the diagnosis of hepatic steatosis with high reproducibility.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Cannella R, Matteini F, Gagliano DS, et al. Performance of Ultrasound Liver Fat Quantification for the Assessment of Hepatic Steatosis Using MRI Fat Fraction as a Reference Standard. Ultrasound Med Biol. 2025. PMID: 40617780. doi:10.1016/j.ultrasmedbio.2025.05.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。