文献速递外周血管介入US

独立高强度聚焦超声治疗部分闭塞离体动物模型的溶栓效果与安全性研究

Investigation of Thrombolysis and Safety of Stand-Alone High-Intensity Focused Ultrasound Therapy in Partially Occluded Ex-Vivo Animal Models.
PubMed 文献 · Ultrasound Med Biol · 2025-07-21

本研究在塑料管模型(模型Ⅰ)和兔腹主动脉模型(模型Ⅱ)中评估独立高强度聚焦超声(HIFU)溶栓的安全性与效果。模型Ⅰ在换能器功率≥120 W且脉冲重复频率≤10 Hz时出现广泛溶栓;模型Ⅱ在功率120-180 W、频率1 Hz时溶栓程度超过70%,治疗时间12-33分钟,血管仅见轻微损伤,平均损伤评分未超过血管破裂阈值(n=3,p>0.05),血栓碎片最大直径<8 μm,结论认为独立HIFU有望成为血栓闭塞性疾病的有效治疗且不引起显著血管损伤。

要点

  • 模型Ⅱ中功率120-180 W、脉冲重复频率1 Hz时溶栓程度超过70%,治疗时间12-33分钟。
  • 该条件下动脉仅见内膜/内中膜轻度撕裂和中膜板层分离,平均损伤评分未超过血管破裂阈值(n=3,p>0.05)。
  • 血栓碎片最大直径<8 μm,与典型毛细血管相当,可能降低远端栓塞风险。

核心结论

  • 结果证实独立HIFU有望成为血栓闭塞性疾病的有效治疗方式,且不引起显著血管损伤。

研究设计与样本

  • 离体动物实验研究,采用塑料管血栓闭塞模型(模型Ⅰ)和兔腹主动脉血栓闭塞模型(模型Ⅱ),使用1.1 MHz HIFU、脉冲重复频率1-100 Hz、换能器功率最高180 W、占空比0.6%以维持组织温度低于43℃。

关键影像表现/征象

  • 模型Ⅰ在换能器功率≥120 W且脉冲重复频率≤10 Hz时可见广泛溶栓。
  • 模型Ⅱ在功率120-180 W、脉冲重复频率1 Hz时溶栓程度超过70%,治疗时间12-33分钟。
  • 上述条件下动脉仅见内膜/内中膜轻度撕裂和中膜板层分离,平均损伤评分未超过血管破裂阈值(n=3,p>0.05),较低功率水平数值略低。

诊断标准与关键数值

  • 模型Ⅰ广泛溶栓条件:换能器功率≥120 W且脉冲重复频率≤10 Hz。
  • 模型Ⅱ溶栓程度超过70%的条件:换能器功率120-180 W、脉冲重复频率1 Hz,治疗时间12-33分钟。
  • 血管损伤评估:平均损伤评分未超过血管破裂阈值(n=3,p>0.05)。
  • 血栓碎片最大直径<8 μm。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Stand-alone high-intensity focused ultrasound (HIFU) therapy is a promising non-invasive approach for treating thrombo-occlusive disease. The objective of this study was to investigate the ability of this approach to achieve safe thrombolysis in clinical treatment.

METHODS: Two types of thrombo-occlusive models, utilizing plastic tubes (model-Ⅰ) and the abdominal aorta of rabbits (model-Ⅱ), were exposed to 1.1-MHz HIFU with a pulse repetition frequency (PRF) of 1-100 Hz and transducer power (Pelect) up to 180 W. A duty cycle of 0.6% was set to maintain tissue temperature below 43℃.

RESULTS: The experimental results from model-I demonstrated that extensive thrombolysis was seen at Pelect ≥ 120 W and PRF ≤ 10 Hz. In the experiments using model-Ⅱ (Pelect = 120-180 W, PRF = 1 Hz) a degree of thrombolysis of over 70% was found with treatment times between 12 and 33 minutes. Under these conditions the arteries appeared to have suffered only minor damage, with slight laceration of the intima/inner media and separation of medial lamellae. The mean damage score did not exceed the threshold for vascular rupture at any power level, with no significant differences observed (n = 3, p > 0.05), but slightly lower values were noted at lower power levels. The maximum diameter of the clot debris was < 8 μm, therefore comparable to that of a typical capillary, minimizing the danger of distal embolization.

CONCLUSION: The results confirm the potential of stand-alone HIFU as an effective treatment of thrombo-occlusive disease without causing significant vascular damage.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。