文献速递腹部技术与安全CT

全病灶碘图直方图分析联合聚焦感兴趣区碘浓度术前预测细胞角蛋白19阳性肝细胞癌

Whole-lesion iodine map histogram analysis combined with focal ROI iodine concentrations for preoperative prediction of cytokeratin 19-positive hepatocellular carcinoma.
PubMed 文献 · Abdom Radiol (NY) · 2025-07-11

回顾性分析82例接受能谱CT检查的肝细胞癌患者,按CK19状态分组,比较全病灶碘图直方图参数与聚焦ROI碘浓度的预测价值。聚焦ROI碘浓度与直方图参数诊断效能相当(AUC分别为0.793和0.779),两者联合预测CK19状态效能最佳(AUC=0.910),交叉验证平均AUC为0.892。

要点

  • 全病灶碘图直方图参数与聚焦ROI碘浓度预测CK19阳性HCC的AUC分别为0.779和0.793,效能相当。
  • 两者联合预测CK19状态AUC达0.910,交叉验证平均AUC为0.892。
  • 直方图参数中仅SD、熵和第1百分位数经相关性分析后保留用于进一步分析。

核心结论

  • 全病灶碘图直方图参数与聚焦ROI碘浓度对术前预测HCC的CK19表达具有相当的临床价值,联合参数表现最佳。

研究设计与样本

  • 回顾性分析82例接受能谱CT检查的HCC患者,按CK19状态分为阳性组和阴性组,手动勾画整个肿瘤区域生成全病灶碘图直方图参数,并在代表性肿瘤层面放置ROI测量碘浓度并归一化至主动脉碘浓度,采用5折交叉验证进行内部验证。

关键影像表现/征象

  • 全病灶碘图直方图的SD、方差、CV、熵及第1、10、25百分位数在CK19阳性组与阴性组间差异有统计学意义(P<0.001至P=0.009)。
  • 聚焦ROI的碘浓度和归一化碘浓度在CK19阳性组与阴性组间差异有统计学意义(P<0.001至P=0.009)。
  • 基于相关性分析,仅SD、熵和第1百分位数被保留用于进一步分析。

诊断标准与关键数值

  • 聚焦ROI碘浓度预测CK19状态的AUC=0.793。
  • 全病灶碘图直方图参数预测CK19状态的AUC=0.779。
  • 聚焦ROI碘浓度联合直方图参数预测CK19状态的AUC=0.910。
  • 联合方法交叉验证平均AUC=0.892,准确率78.1%,敏感度78.6%,特异度77.5%,Cohen κ=0.561。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the value of whole-lesion iodine map (IM) histogram analysis and focal region-of-interest (ROI) iodine concentrations (ICs) in preoperative prediction of cytokeratin 19 (CK19)-positive hepatocellular carcinoma (HCC).

METHODS: We retrospectively analyzed 82 patients with HCC who underwent spectral computed tomography (CT). Based on their CK19 status, the patients were categorized into positive and negative groups. The whole-lesion IM histogram parameters (mean, standard deviation [SD], variance, coefficient of variation [CV], skewness, kurtosis, entropy, and 1st, 10th, 25th, 50th, 75th, 90th, and 99th percentiles) were generated by manually delineating the entire tumor region for each HCC. In other methods, IC was measured from IM by placing ROIs at representative tumor levels and normalized to aortic IC. The t-test, Mann-Whitney U, and χ2 test were used for group comparisons. p-values for histogram parameters were adjusted using the false discovery rate (FDR), and Pearson correlation was used to assess multicollinearity among significant parameters. Receiver operating characteristic (ROC) curve analysis was used to assess diagnostic performance, with AUC comparisons performed using DeLong's test. Internal validation was achieved using a 5-fold cross-validation.

RESULTS: The IC and normalized IC (NIC) of the focal ROI and the SD, variance, CV, entropy, 1st, 10th, and 25th percentiles of the whole-lesion IM histogram displayed significant differences between the CK19-positive and CK19-negative groups (P < 0.001 to P = 0.009). Based on the correlation analysis, only SD, entropy, and the 1st percentile were retained for further analysis. ROC curve analysis demonstrated comparable diagnostic performance of histogram variables and focal ROI ICs (AUC = 0.779, 0.793, respectively). Combining parameters from both focal ROI ICs and histogram analysis provided optimal diagnostic performance for predicting CK19 status (AUC = 0.910). Cross-validation of this combined approach yielded a mean AUC of 0.892, accuracy of 78.1%, sensitivity of 78.6%, specificity of 77.5%, and Cohen's κ of 0.561.

CONCLUSION: Whole-lesion IM histogram parameters and focal ROI ICs present comparable clinical value for preoperatively predicting CK19 expression in HCC, with the combined parameters exhibiting the best performance.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Ming X, Zhang H, Yang S, et al. Whole-lesion iodine map histogram analysis combined with focal ROI iodine concentrations for preoperative prediction of cytokeratin 19-positive hepatocellular carcinoma. Abdom Radiol (NY). 2025. PMID: 40643655. doi:10.1007/s00261-025-05116-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。