下腔静脉滤器穿透主动脉病例的系统综述
该系统综述检索1967年1月至2025年4月文献,纳入35篇报告共53例下腔静脉滤器穿透主动脉患者,涉及11种滤器。滤器置入至诊断中位时间5.0年,52.8%有症状,最常见为腹痛(30.2%)。67.9%行滤器取出,18.0%仅修复主动脉未取滤器,11.3%保守处理,2例(4.0%)死于腹膜后血肿。
要点
- 滤器穿透主动脉多在置入后数年发现,中位诊断时间5.0年。
- 约半数患者有症状,最常见为腹痛(30.2%)。
- 可并发主动脉假性动脉瘤、动脉血栓、腹膜后血肿等。
核心结论
- 下腔静脉滤器穿透主动脉不常见但可能危及生命,近半数穿透患者有症状;对合并邻近组织或脏器穿透者,手术取出可能是最佳选择;无症状且无影像学合并损伤者,血管内取出是相对安全可行的替代策略。
研究设计与样本
- 系统文献综述,检索1967年1月至2025年4月发表的下腔静脉滤器穿透主动脉相关研究,共纳入35篇报告、53例患者、11种下腔静脉滤器。
关键影像表现/征象
- 滤器置入至诊断主动脉穿透的中位时间为5.0年(四分位距:1.7至8.0年)。
- 53例中28例(52.8%)有症状,19例(35.9%)无症状,6例(11.3%)症状情况未知。
- 最常见症状为腹痛,占30.2%。
- 15例报告出现一种或多种并发症:主动脉假性动脉瘤7例、动脉血栓5例、腹膜后血肿4例、动静脉瘘2例、主动脉夹层1例。
临床应用与阅片要点
- 53例中36例(67.9%)行滤器取出,其中血管内取出24例、手术取出12例。
- 9例(18.0%)仅修复穿孔主动脉而未取出滤器,6例(11.3%)接受保守处理,2例(4.0%)死于腹膜后血肿。
- 作者认为,对合并邻近组织或脏器穿透的患者,手术取出可能是最佳选择。
- 作者认为,无症状且无影像学可见合并损伤的患者,血管内取出已被证明是相对安全可行的替代处理策略。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To assess the clinical presentation of aortic penetration by inferior vena cava (IVC) filters, as well as common management strategies and clinical outcomes.
METHODS: A systematic search of the literature was conducted to identify studies pertaining to aortic penetration by IVC filters published between January 1967 and April 2025.
RESULTS: A total of 35 reports regarding aortic penetration by IVC filters were identified, including a total of 53 patients and 11 types of IVC filters. The median time from filter placement to the diagnosis of aortic penetration was 5.0 years (interquartile range: 1.7, 8.0 years). Of the 53 patients, 28 (52.8%) were symptomatic, 19 (35.9%) were asymptomatic, and 6 (11.3%) had unknown symptomatology. The most frequently reported symptom was abdominal pain (30.2%). Fifteen patients were reported to have experienced one or more of the following complications: aortic pseudoaneurysm (n = 7), arterial thrombosis (n = 5), retroperitoneal hematoma (n = 4), arteriovenous fistula (n = 2), and aortic dissection (n = 1). Of the 53 patients, 36 (67.9%) underwent filter retrieval (endovascular retrieval, n = 24; surgical retrieval, n = 12), 9 (18.0%) underwent repair of the perforated aorta without filter removal, 6 (11.3%) received conservative management, and 2 (4.0%) died of retroperitoneal hematoma.
CONCLUSIONS: Aortic penetration by IVC filters is uncommon but potentially life-threatening. Symptomatic patients account for nearly half of all penetrations. For patients demonstrating concomitant penetration into adjacent tissues or visceral organs, surgical retrieval may provide the best option. In asymptomatic patients with no radiologically evident concomitant injuries, endovascular retrieval has been demonstrated to serve as a relatively safe and feasible alternative management strategy.
引用
- Bai Y, Wang K, Jia Z, et al. A systematic review of cases of aortic penetration by inferior vena cava filters. Abdom Radiol (NY). 2025. PMID: 40673936. doi:10.1007/s00261-025-05131-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。