文献速递心血管USMR

左心室涡流与血流动力学力:高帧率超声粒子图像测速与四维血流磁共振的对比

Vortices and Hemodynamic Forces in the Left Ventricle: Comparison between High Frame Rate Echo-Particle Image Velocimetry and 4D Flow MRI.
PubMed 文献 · Ultrasound Med Biol · 2025-07-24

本研究在26例转诊心脏磁共振的患者中,比较超声粒子图像测速(echoPIV)与四维血流磁共振(4D flow MRI)测量的纵向血流动力学力(HDFlong)和主涡流循环(VC),两者相关性强(相关系数0.70和0.66,RMS回归r=0.80和0.76),且左心室收缩功能受损患者HDFlong和容积归一化VC RMS显著降低。

要点

  • echoPIV与4D flow MRI测量的HDFlong和主VC高度一致,相关系数分别为0.70和0.66。
  • 左心室收缩功能受损患者HDFlong和容积归一化VC RMS显著降低。
  • echoPIV与MRI的差异小于不同病理状态间的差异。

核心结论

  • echoPIV能准确量化不同心脏状态下的HDFlong和VC,与4D flow MRI高度一致;echoPIV与MRI的差异小于病理谱系间的差异;在本研究队列中,HDFlong和VC幅度可与潜在心脏状况相关。

研究设计与样本

  • 研究纳入26例转诊心脏MRI的患者,采集高帧率超声造影(三个心尖切面)和4D flow MRI;图像质量不足或与MRI对齐不佳的超声切面被排除在比较之外;采用时间轨迹相关系数和时间均方根值的线性回归比较两种模态的HDF和VC。

诊断标准与关键数值

  • 纵向HDF(HDFlong)时间轨迹相关系数为0.70,主VC时间轨迹相关系数为0.66。
  • HDF和VC的RMS线性回归r分别为0.80和0.76。
  • 左心室收缩功能受损患者HDFlong和容积归一化VC RMS显著降低。

临床应用与阅片要点

  • echoPIV测量的HDFlong和主VC与4D flow MRI高度一致,可提供与血流动力学力及涡流强度相关的定量信息。
  • 左心室收缩功能受损时HDFlong和容积归一化VC RMS降低,阅片时可结合收缩功能状态解读涡流参数。

局限性

  • 图像质量不足或与MRI对齐不佳的超声切面被排除在比较之外。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Assessing advanced blood flow parameters, such as hemodynamic forces (HDF) and vortex circulation (VC), may offer insights into cardiac function and remodeling. Vortices conserve energy and balance myocardial workload, with VC reflecting vortex intensity and size. HDF quantifies the intraventricular pressure gradients driving blood flow. This study compares HDF and VC between echoPIV and 4D flow MRI, as well as between patient groups.

METHODS: We acquired high-frame-rate contrast-enhanced ultrasound (three apical views) and 4D flow MRI from 26 patients referred for cardiac MRI. Echo image planes with insufficient quality or poor alignment with MRI were excluded from the comparison. Time-trace correlation coefficients (of the time traces) and linear regressions of the temporal root mean square (RMS) values were used to compare HDF and VC between modalities.

RESULTS: Echo and MRI measurements of longitudinal HDF (HDFlong) and principal VC showed strong correspondence. Correlation coefficients were 0.70 (HDFlong) and 0.66 (VC), with linear regression yielding r = 0.80 and r = 0.76 for HDF and VC RMS. Patients with impaired left ventricle systolic function showed significantly lower HDFlong and lower volume-normalized VC RMS.

CONCLUSION: EchoPIV accurately quantified HDFlong and VC across heart conditions, aligning closely with 4D flow MRI. Differences between echoPIV and MRI were smaller than those observed across pathology spectrum. Within this study cohort, HDFlong and VC magnitudes could be correlated to underlying heart conditions.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Han Y, Bowen DJ, Barreto BL, et al. Vortices and Hemodynamic Forces in the Left Ventricle: Comparison between High Frame Rate Echo-Particle Image Velocimetry and 4D Flow MRI. Ultrasound Med Biol. 2025. PMID: 40713310. doi:10.1016/j.ultrasmedbio.2025.06.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。