文献速递心血管CT

光子计数探测器CT血管成像标准与超高分辨率模式诊断冠状动脉狭窄:以有创血管造影为参考的前瞻性研究

Photon-Counting Detector CTA in Standard- and Ultrahigh-Resolution Modes for Diagnosing Coronary Artery Stenosis Using Invasive Angiography as the Reference: A Prospective Study.
PubMed 文献 · AJR Am J Roentgenol · 2025-07-02

前瞻性研究纳入2023年10月至2024年10月住院患者,行光子计数探测器CT冠状动脉CTA,在标准分辨率(SR)和超高分辨率(UHR)模式间交替,以有创冠状动脉造影为参考标准。SR重建为常规(SRnormal)和虚拟去钙(SRVNCa)图像,UHR重建为常规(UHRnormal)和薄层(UHRthin)图像。SR组和UHR组各61例,UHRthin的敏感度、特异度和准确度最高(读者1为100.0%、98.6%、98.8%),SRVNCa优于SRnormal,UHRthin优于UHRnormal和SRVNCa。

要点

  • UHRthin图像(0.2 mm层厚、Bv64卷积核)对≥50%狭窄的段水平敏感度、特异度和准确度最高(读者1为100.0%、98.6%、98.8%)。
  • SRVNCa较SRnormal提高特异度(读者1 91.6% vs 89.9%,读者2 92.3% vs 88.8%)和读者2的准确度(92.5% vs 89.6%)。
  • UHRthin较UHRnormal在敏感度、特异度和准确度上均有显著提高(读者1敏感度100.0% vs 96.0%,特异度98.6% vs 92.4%,准确度98.8% vs 93.0%)。

核心结论

  • 光子计数探测器CT冠状动脉CTA在SR或UHR模式下均获得高诊断性能;SRVNCa性能高于SRnormal,UHRthin性能高于UHRnormal和SRVNCa。

研究设计与样本

  • 前瞻性研究,SR组61例(平均年龄67±9岁,男46例、女15例,分析788个段),UHR组61例(67±11岁,男43例、女18例,分析825个段),参与者交替接受SR(准直144×0.4 mm)和UHR(准直120×0.2 mm)模式扫描。

诊断标准与关键数值

  • 以有创冠状动脉造影为参考标准,狭窄≥50%定义为显著狭窄;读者1段水平敏感度、特异度、准确度:SRnormal 92.9%、89.9%、90.5%,SRVNCa 92.9%、91.6%、91.8%,UHRnormal 96.0%、92.4%、93.0%,UHRthin 100.0%、98.6%、98.8%;读者2:SRnormal 92.9%、88.8%、89.6%,SRVNCa 93.5%、92.3%、92.5%,UHRnormal 96.0%、91.6%、92.2%,UHRthin 100.0%、98.9%、99.0%。

临床应用与阅片要点

  • 作者结论认为光子计数探测器CT冠状动脉CTA在SR或UHR模式下均获得高诊断性能,SRVNCa性能高于SRnormal,UHRthin性能高于UHRnormal和SRVNCa;临床影响为 findings 将有助于优化光子计数探测器CT冠状动脉CTA协议。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND. The literature reports excellent diagnostic performance of coronary CTA using photon-counting detector (PCD) CT, albeit obtained using various acquisition and reconstruction protocols. OBJECTIVE. The purpose of this study was to assess the diagnostic performance for detecting significant stenosis of coronary CTA performed by PCD CT with various standard-resolution (SR) and ultrahigh-resolution (UHR) protocols, using invasive coronary angiography (ICA) as the reference standard. METHODS. This prospective study enrolled inpatients undergoing coronary CTA between October 2023 and October 2024. Participants underwent coronary CTA by PCD CT, sequentially alternating between SR (collimation: 144 × 0.4 mm) and UHR (collimation: 120 × 0.2 mm) modes across participants. SR examinations were reconstructed into normal (SRnormal) and virtual noncalcium (SRVNCa) image sets, both using 0.6-mm slice thickness and Bv40 kernel. UHR examinations were reconstructed into normal (UHRnormal [0.6-mm slice thickness, Bv40 kernel]) and thin (UHRthin [0.2-mm slice thickness, Bv64 kernel]) image sets. Two radiologists independently measured the diameter of stenoses. The final analysis included patients who underwent ICA after CTA; a cardiologist reviewed the ICA images to determine the reference standard. Stenoses were considered significant at a threshold of 50% or greater. RESULTS. The SR group included 61 patients (mean age, 67 ± 9 [SD] years; 46 men, 15 women; 788 segments analyzed). The UHR group included 61 patients (67 ± 11 years; 43 men, 18 women; 825 segments analyzed). Per-segment sensitivity, specificity, and accuracy for reader 1 were 92.9%, 89.9%, and 90.5% for SRnormal, respectively; 92.9%, 91.6%, and 91.8% for SRVNCa; 96.0%, 92.4%, and 93.0% for UHRnormal; and 100.0%, 98.6%, and 98.8% for UHRthin; and for reader 2 were 92.9%, 88.8%, and 89.6% for SRnormal; 93.5%, 92.3%, and 92.5% for SRVNCa; 96.0%, 91.6%, and 92.2% for UHRnormal; and 100.0%, 98.9%, and 99.0% for UHRthin. Significant (p < .05) differences included SRVNCa versus SRnormal for specificity for both readers and accuracy for reader 2; UHRthin versus UHRnormal for sensitivity, specificity, and accuracy for both readers; and UHRthin versus SRVNCa for sensitivity, specificity, and accuracy for both readers. CONCLUSION. Coronary CTA performed by PCD CT achieved high diagnostic performance in the SR or UHR mode. Performance was higher for SRVNCa than SRnormal and for UHRthin than either UHRnormal or SRVNCa. CLINICAL IMPACT. The findings will help to optimize protocols for coronary CTA performed by PCD CT.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Wang M, Li X, Xu Z, et al. Photon-Counting Detector CTA in Standard- and Ultrahigh-Resolution Modes for Diagnosing Coronary Artery Stenosis Using Invasive Angiography as the Reference: A Prospective Study. AJR Am J Roentgenol. 2025. PMID: 40600512. doi:10.2214/AJR.25.33021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。