文献速递妇产影像儿科影像心血管US

法洛四联症胎儿肺动脉弹性受损与心室功能

Impaired Pulmonary Arterial Elasticity and Ventricular Function in Fetuses With Tetralogy of Fallot.
PubMed 文献 · J Ultrasound Med · 2025-07-05

前瞻性研究纳入42例法洛四联症胎儿与84例对照,用M型超声心动图测量主肺动脉及其分支的应变,发现法洛四联症胎儿主肺动脉应变显著低于对照,且重度法洛四联症低于轻中度;法洛四联症胎儿右室收缩与舒张功能受损,主肺动脉应变与右室IRT、MPI负相关、与ET正相关。

要点

  • 法洛四联症胎儿主肺动脉应变显著低于正常胎儿(P < .05)。
  • 重度法洛四联症胎儿主肺动脉应变显著低于轻中度法洛四联症胎儿(P < .05)。
  • 法洛四联症胎儿主肺动脉应变与右室IRT、MPI负相关,与右室ET正相关(均P < .05)。

核心结论

  • 法洛四联症胎儿在妊娠中晚期主肺动脉应变明显减低,右室收缩与舒张功能受损,主肺动脉应变受损与右室功能相关。

研究设计与样本

  • 前瞻性研究,纳入42例法洛四联症胎儿与84例对照,采用M型超声心动图测量肺动脉主干及其分支的舒张期最小血管内径(Dmin)与收缩期最大内径(Dmax),按公式100 × (Dmax - Dmin)/Dmin计算主肺动脉、左肺动脉中段与右肺动脉中段的应变。

诊断标准与关键数值

  • 法洛四联症胎儿主肺动脉应变显著低于对照(P < .05);重度法洛四联症胎儿主肺动脉应变显著低于轻中度法洛四联症胎儿(P < .05);法洛四联症胎儿右室IRT(r = -0.452)与MPI(r = -0.261)与主肺动脉应变负相关(均P < .05),右室ET(r = 0.286)与主肺动脉应变正相关(P < .05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the elasticity of the main pulmonary artery (MPA) and its branches in fetuses with tetralogy of Fallot (TOF) with that of normal fetuses.

METHODS: A prospective study of 42 fetuses with TOF and 84 controls was conducted. The minimum vascular internal diameter in the diastolic period (Dmin) and the maximum diameter in the systolic period (Dmax) of the pulmonary trunk and its branches were measured via M-mode echocardiography. The strain of the MPA, mid-left pulmonary artery (MLPA) and mid-right pulmonary artery (MRPA) was calculated through the formula 100 × (Dmax - Dmin)/Dmin. Correlations between the strain of the pulmonary artery and ventricular function were evaluated in all fetuses with TOF.

RESULTS: The strain of the MPA in fetuses with TOF was significantly lower than that in controls (P < .05). Moreover, the strain of the MPA in fetuses with severe TOF was significantly lower than that in fetuses with mild to moderate TOF (P < .05). The systolic and diastolic functions of the right ventricle (RV) are impaired in fetuses with TOF. The isovolumic relaxation time (IRT) and myocardial performance index (MPI) of RV were negatively correlated with the strain of the MPA (r = -0.452 and -0.261, all P < .05), whereas the ejection time (ET) of RV (r = 0.286, P < .05) was positively correlated with the strain of the MPA in fetuses with TOF.

CONCLUSION: The strain of the MPA was obviously decreased in fetuses with TOF during the second and third trimesters of pregnancy. The systolic and diastolic functions of the RV were impaired in fetuses with TOF. The impaired strain of the MPA was correlated with RV function in fetuses with TOF.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Liu Y, Zhou D, Yang Y, et al. Impaired Pulmonary Arterial Elasticity and Ventricular Function in Fetuses With Tetralogy of Fallot. J Ultrasound Med. 2025. PMID: 40616452. doi:10.1002/jum.16740

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。