文献速递心血管US

利用自然剪切波预测左心室充盈压:超越常规超声心动图的增量价值

Prediction of Left Ventricular Filling Pressures Using Natural Shear Waves: Incremental Value Over Conventional Echocardiography.
PubMed 文献 · JACC Cardiovasc Imaging · 2025-07-30

本研究前瞻性纳入85例患者,在导管检查后即刻行高帧率超声心动图测量二尖瓣关闭时的剪切波速度,并与常规超声参数及2021指南算法对比预测有创左心室充盈压。结果显示剪切波速度预测左心室舒张末期压的AUC达0.95,优于常规参数和指南算法。

要点

  • 二尖瓣关闭时剪切波速度预测左心室舒张末期压升高AUC为0.95(敏感度92%、特异度94%,阈值4.8 m/s)。
  • 剪切波速度预测左心室舒张中期压升高AUC为0.79(敏感度87%、特异度65%),与指南算法相似。
  • 急性失代偿心衰患者利尿后剪切波速度由7.1±1.7 m/s降至5.3±1.3 m/s(P<0.002)。

核心结论

  • 与多变量指南算法相比,舒张末期剪切波速度作为单一指标检测左心室舒张中期压升高的准确度相似,检测左心室舒张末期压升高的准确度更高;剪切波弹性成像可能成为无创评估舒张功能的新工具。

研究设计与样本

  • 前瞻性研究纳入85例患者,行有创左心室舒张中期压和左心室舒张末期压测量,导管检查后即刻行高帧率超声(平均帧率1050±220 Hz)和常规超声心动图,于前间隔壁测量二尖瓣关闭时剪切波速度;另在16例急性失代偿心衰患者中于入院时和利尿治疗后测试剪切波速度的直接反应。

关键影像表现/征象

  • 二尖瓣关闭时剪切波速度与左心室舒张末期压强相关(r=0.71;P<0.001)。
  • 急性失代偿心衰患者利尿治疗后剪切波速度较治疗前降低(7.1±1.7 m/s vs 5.3±1.3 m/s;P<0.002)。

诊断标准与关键数值

  • 剪切波速度预测左心室舒张中期压升高:AUC 0.79,敏感度87%,特异度65%(阈值4.8 m/s)。
  • 剪切波速度预测左心室舒张末期压升高:AUC 0.95,敏感度92%,特异度94%(阈值4.8 m/s)。
  • 常规超声单参数与左心室充盈压相关性中等(Pearson r 0.39~0.58),检测左心室充盈压升高的AUC为0.66~0.79。
  • 2021指南多参数算法预测左心室舒张中期压升高AUC 0.78,预测左心室舒张末期压升高AUC 0.60。

临床应用与阅片要点

  • 剪切波弹性成像可能作为无创评估左心室充盈压和舒张功能的新工具,但原文为探索性研究,尚未给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Increased myocardial stiffness can lead to diastolic dysfunction, resulting eventually in increased left ventricular filling pressures (LVFPs). The clinical assessment of left ventricular (LV) diastolic function is challenging. Shear wave elastography is a novel method based on tracking shear waves, such as those induced by mitral valve closure (MVC), using high frame rate (HFR) echocardiography. The propagation velocity of shear waves is directly related to myocardial stiffness.

OBJECTIVES: This study investigated whether shear wave velocity at MVC is related to invasively measured LVFP.

METHODS: Eighty-five patients were prospectively enrolled. Left ventricular mid-diastolic pressure (LVMDP) and left ventricular end-diastolic pressure (LVEDP) were invasively measured. HFR (average frame rate: 1,050 ± 220 Hz) and conventional echocardiography were performed immediately after catheterization. Shear wave velocity at MVC was measured in the anteroseptal wall. The findings were compared with conventional echocardiographic parameters and the multiparametric 2021 guideline-recommended algorithm for the estimation of LVFP. The direct response of shear wave velocity at MVC on changing LV filling pressures was tested in a group of 16 patients with acutely decompensated heart failure (DHF) on admission and after diuretic therapy.

RESULTS: Single conventional echocardiographic parameters correlated moderately with LVFP (Pearson r between 0.39 and 0.58) and had a moderate ability to detect elevated LVFP (AUC between 0.66 and 0.79). This was similar for the multiparametric guideline algorithm (LVMDP AUC: 0.78; LVEDP AUC: 0.60). In comparison, shear wave velocities at MVC as a single measure correlated strongly with LVEDP (r = 0.71; P < 0.001) and had an similar ability to predict elevated LVMDP (AUC: 0.79; sensitivity: 87%; specificity: 65%) and an excellent ability to predict elevated LVEDP (AUC: 0.95; sensitivity: 92%; specificity: 94%) when a cutoff value of 4.8 m/s was used. In DHF patients, we observed a significant decrease in shear wave velocity after diuretic therapy (7.1 ± 1.7 m/s vs 5.3 ± 1.3 m/s; P < 0.002).

CONCLUSIONS: In comparison with the multivariable guideline approach, end-diastolic shear wave velocity as a single measure had similar accuracy in detecting elevated LVMDP and a higher accuracy for LVEDP. Shear wave elastography might therefore be a promising new tool for the noninvasive assessment of diastolic function.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Werner AE, Bézy S, Wouters L, et al. Prediction of Left Ventricular Filling Pressures Using Natural Shear Waves: Incremental Value Over Conventional Echocardiography. JACC Cardiovasc Imaging. 2025. PMID: 40742357. doi:10.1016/j.jcmg.2025.04.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。