混合手术室内锥形束CT引导下经肺内精细调整增强肺部病灶微波消融
该回顾性研究分析了本院前150例连续在混合手术室全麻下接受锥形束CT引导经皮微波消融的病例,纳入127例患者145个病灶。结果显示肺内精细调整使亚厘米病灶诊断率从10.1%提升至50.0%,同轴针活检消融使气胸率从12.1%降至6%,早期队列发生两例致命并发症;作者认为该技术安全可行,多种技术策略可提高疗效。
要点
- 肺内精细调整可将亚厘米肺病灶活检诊断率由10.1%提高至50.0%。
- 同轴针同步活检与消融使气胸发生率由12.1%降至6%。
- 早期队列出现两例致命并发症,操作安全性需关注。
核心结论
- 该微波消融技术安全可行,多种技术策略可提高其疗效;经肺内精细调整法显著提高小结节活检诊断率。
研究设计与样本
- 回顾性研究,纳入2020年7月至2024年1月在配备锥形束CT的混合手术室接受微波消融的150例连续患者中的127例(145个病灶),全麻下固定患者后行锥形束CT扫描、iGuide针道规划、激光束与增强透视引导下置针及消融后消融区评估。
临床应用与阅片要点
- 作者认为该微波消融技术安全可行,经肺内精细调整法显著提高小结节活检诊断率,同轴针同步活检与消融可降低气胸发生率。
局限性
- 本研究为回顾性研究。
- 早期队列出现两例致命并发症。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To review outcomes of the first 150 consecutive microwave ablation (MWA) cases at our institution to assess the safety and diagnostic performance of a new workflow for cone-beam computed tomography (CBCT)-guided percutaneous MWA performed under general anesthesia in a hybrid operating room (HOR).
MATERIALS AND METHODS: This retrospective study included 150 consecutive patients who underwent MWA in the CBCT-equipped HOR between July 2020 and January 2024. The procedural workflow involved general anesthesia with patient fixation, CBCT scanning, iGuide needle pathway planning, needle placement with a laser beam and augmented fluoroscopy guidance, and post-procedure ablation-zone assessment. Technical advancements included the use of a coaxial needle for synchronous biopsy and ablation and a fine adjustment tool.
RESULTS: In total, 145 lesions in 127 patients (82 women and 45 men; mean age, 59.8±13.1years [standard deviation]; single nodule, 113 patients; multiple nodules, 14 patients) were analyzed. The median global operating-room time, procedure time, total dose area product, and postoperative stay were 110 min, 45 min, 19,701 μGym², and 2 days, respectively. CBCT-guided MWA improved diagnostic yield for subcentimeter lung lesions to 50.0% with intra-parenchymal fine adjustment, compared to 10.1% without. Pneumothorax rates decreased significantly to 6% with coaxial needles for biopsy and ablation, compared to 12.1% with prior methods. Post-procedure complications were mostly tolerable, with two fatal complications occurring in the early cohort.
CONCLUSION: The MWA technique is safe and feasible, with various technical strategies enhancing its efficacy. The intra-parenchymal fine adjustment method significantly improves small-nodule biopsy yield.
引用
- Chang LK, Su PK, Malwade S, et al. Enhancing Microwave Ablation for Lung Lesions with Cone-Beam Computed Tomography Guidance and Intrapulmonary Fine Adjustment in a Hybrid Operating Room. Acad Radiol. 2025. PMID: 40683762. doi:10.1016/j.acra.2025.06.058
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。