文献速递胸部CTMR

AI增强三维梯度回波MRI:用于肺结节检出与Lung-RADS分类的无辐射CT替代方案

AI-Enhanced 3D Gradient Echo MRI: A Radiation-Free Alternative to CT for Lung Nodule Detection and Lung-RADS Classification.
PubMed 文献 · Acad Radiol · 2025-07-28

前瞻性纳入75例肺结节患者,行胸部CT与AI加速三维梯度回波MRI,三位放射科医师盲法评估结节检出率、大小、形态及Lung-RADS分类;MRI检出率96.3%,Lung-RADS与CT几乎完全一致,形态一致性中等至高度。

要点

  • AI加速三维梯度回波MRI肺结节检出率96.3%,135个结节中漏诊5个。
  • MRI与CT的Lung-RADS分类几乎完全一致(两位读者k=0.86、0.90),一位读者为高度一致(k=0.69)。
  • MRI与CT结节直径偏差0.1 mm(1.96 SD:±5.87 mm)。

核心结论

  • 加速三维梯度回波MRI对肺结节检出率高,Lung-RADS评分和形态学评估与CT相当。

研究设计与样本

  • 前瞻性研究,纳入75例良恶性肺结节患者(平均年龄65±12岁,44%为女性,2022年3月至2024年7月),行胸部CT与采用并行成像、压缩感知及AI加速(CSAI)的三维梯度回波MRI,由三名放射科医师(经验分别为4年、9年、10年)盲法评估。

关键影像表现/征象

  • CSAI梯度回波序列标称扫描时间3分53秒,结节检出率96.3%。
  • 全部读者共漏诊135个结节中的5个。
  • MRI结节直径与CT偏差0.1 mm(1.96 SD:±5.87 mm)。

诊断标准与关键数值

  • 结节大小组间一致性:CT的ICC为0.995,CSAI的ICC为0.993。
  • 形态学组间一致性:CT的Fleiss kappa为0.95,MR的Fleiss kappa为0.88。
  • CT与MRI的Lung-RADS一致性:两位读者k=0.86、0.90(几乎完全一致),一位读者k=0.69(高度一致)。

临床应用与阅片要点

  • 作者结论认为加速三维梯度回波MRI对肺结节检出率高,Lung-RADS评分和形态学评估与CT相当。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: This study aims to evaluate the capabilities of a 3D gradient echo MRI sequence for the detection and classification of pulmonary nodules, specifically in relation to the lung CT screening reporting and data system (Lung-RADS).

MATERIALS AND METHODS: In a prospective trial, 75 patients (mean age 65±12years; 44% women) with benign and malignant lung nodules (March 2022-July 2024) underwent chest CT and 3D gradient echo MRI using parallel imaging, compressed sensing, and AI acceleration (CSAI). Three radiologists (experience: 4, 9, and 10 years) assessed detection rates, nodule size, morphology, and Lung-RADS classification in a blinded study. Intra- and inter-rater reliability were evaluated using intraclass correlation coefficient (ICC) for size and Cohen's/Fleiss' kappa for Lung-RADS and morphology.

RESULTS: The CSAI gradient echo sequence achieved a detection rate of 96.3%, missing 5 out of 135 nodules across all readers. Nominal scan time was 3:53 min. MRI nodule diameter deviated from CT by 0.1 mm (1.96 SD: ±5.87mm). Excellent inter-rater agreement was observed for nodule size and morphology (Size: ICC-CT: 0.995; ICC-CSAI: 0.993; Morphology: Fleiss' kappa CT: 0.95; Fleiss' kappa MR: 0.88). Intra-rater morphology agreement between CT and MRI ranged from moderate to substantial (Cohen's-kappa: 0.55-0.71; p<.001). Lung-RADS agreement between CT and MRI was almost perfect for two readers (k=0.86, 0.90), and substantial for one (k=0.69), with near perfect inter-rater agreement (Fleiss' kappa CT:0.94; MR:0.87).

CONCLUSION: Accelerated 3D gradient echo MRI showed high detection rates for pulmonary nodules with Lung-RADs scores and morphological assessments comparable to CT.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Marka AW, Steinhardt M, Rahn L, et al. AI-Enhanced 3D Gradient Echo MRI: A Radiation-Free Alternative to CT for Lung Nodule Detection and Lung-RADS Classification. Acad Radiol. 2025. PMID: 40730779. doi:10.1016/j.acra.2025.07.030

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。